A Stability Indicating Reverse Phase High Performance Liquid Chromatography Method for Related Substances of Sofosbuvir in Tablet Dosage Form

Binal N Patel, Hitesh J Vekaria
{"title":"A Stability Indicating Reverse Phase High Performance Liquid Chromatography Method for Related Substances of Sofosbuvir in Tablet Dosage Form","authors":"Binal N Patel, Hitesh J Vekaria","doi":"10.25004/ijpsdr.2023.150501","DOIUrl":null,"url":null,"abstract":"Sofosbuvir is an antiviral drug that is used to treat hepatitis C. A present investigation deals with simple, sensitive, rapid, precise and accurate reverse phase high-performance chromatography (RP-HPLC) method developed and validated for related substances of sofosbuvir in tablet dosage form. The chromatographic separation was achieved on a Kromasil 100 C18 (250 × 4.6 mm, 5 μ) column. A sofosbuvir and its impurities were extracted by composed mixture of Mobile Phase A: buffer solution: acetonitrile (97.5:2.5% v/v) and Mobile Phase B: acetonitrile, isopropyl alcohol, methanol and purified water (60:20:10:10 % v/v/v/v) using with flow rate was 1-mL/min, column temperature was 25°C, injection volume was 10 μL, Vial thermostat temperature was 10°C. The UV detection was carried out at 263 nm. The retention time of sofosbuvir, methyl ester and ethyl ester were 54.28, 36.31 and 43.77, respectively. The method shows linearity with correlation coefficient of sofosbuvir and its impurity was 0.999 over the 0.5–7.5 ppm range. The average recovery was found to be 90.2–113.9%. The LoD and LoQ for sofosbuvir and its impurities were found to be 0.1 and 0.5 μg/mL, respectively. The method was validated as per ICH guidelines. The developed method was precise, accurate, novel and detectable towards sofosbuvir and its impurity. This method is efficient in separating the sofosbuvir and its impurity. Hence, the proposed method can be utilized for the determination of related substances in routine analysis in quality control department of pharmaceutical Industry.","PeriodicalId":14278,"journal":{"name":"International Journal of Pharmaceutical Sciences and Drug Research","volume":"55 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Pharmaceutical Sciences and Drug Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25004/ijpsdr.2023.150501","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Sofosbuvir is an antiviral drug that is used to treat hepatitis C. A present investigation deals with simple, sensitive, rapid, precise and accurate reverse phase high-performance chromatography (RP-HPLC) method developed and validated for related substances of sofosbuvir in tablet dosage form. The chromatographic separation was achieved on a Kromasil 100 C18 (250 × 4.6 mm, 5 μ) column. A sofosbuvir and its impurities were extracted by composed mixture of Mobile Phase A: buffer solution: acetonitrile (97.5:2.5% v/v) and Mobile Phase B: acetonitrile, isopropyl alcohol, methanol and purified water (60:20:10:10 % v/v/v/v) using with flow rate was 1-mL/min, column temperature was 25°C, injection volume was 10 μL, Vial thermostat temperature was 10°C. The UV detection was carried out at 263 nm. The retention time of sofosbuvir, methyl ester and ethyl ester were 54.28, 36.31 and 43.77, respectively. The method shows linearity with correlation coefficient of sofosbuvir and its impurity was 0.999 over the 0.5–7.5 ppm range. The average recovery was found to be 90.2–113.9%. The LoD and LoQ for sofosbuvir and its impurities were found to be 0.1 and 0.5 μg/mL, respectively. The method was validated as per ICH guidelines. The developed method was precise, accurate, novel and detectable towards sofosbuvir and its impurity. This method is efficient in separating the sofosbuvir and its impurity. Hence, the proposed method can be utilized for the determination of related substances in routine analysis in quality control department of pharmaceutical Industry.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
片剂索非布韦相关物质的稳定性指示反相高效液相色谱法
索非布韦是一种用于治疗丙型肝炎的抗病毒药物。本研究针对片剂中索非布韦的相关物质开发并验证了一种简单、灵敏、快速、精确的反相高效色谱(RP-HPLC)方法。色谱分离采用 Kromasil 100 C18(250 × 4.6 mm,5 μ)色谱柱。索非布韦及其杂质由流动相 A:缓冲溶液:乙腈(97.5:2.5% v/v)和流动相 B:乙腈、异丙醇、甲醇和纯净水(60:20:10:10 % v/v/v/v)组成的混合物萃取,流速为 1 mL/min,柱温为 25°C,进样量为 10 μL,小瓶恒温器温度为 10°C。紫外检测波长为 263 nm。索非布韦、甲酯和乙酯的保留时间分别为 54.28、36.31 和 43.77。索非布韦及其杂质在 0.5-7.5 ppm 范围内的线性相关系数为 0.999。平均回收率为 90.2-113.9%。索非布韦及其杂质的 LoD 和 LoQ 分别为 0.1 和 0.5 μg/mL。根据 ICH 指南对该方法进行了验证。所开发的方法精密、准确、新颖,可检测索非布韦及其杂质。该方法可有效分离索非布韦及其杂质。因此,该方法可用于制药行业质量控制部门常规分析中相关物质的测定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Isolation, Characterization, In-silico and Enzyme Inhibition Studies of Bougainvillea spectabilis against a Hyperoxaluria Initiator Glycolate Oxidase Development and Optimization of Enzalutamide Nanosuspension by Design of Experiments for Dissolution Enhancement Expeditious Microwave-assisted Synthesis of 1,3-Benzoxazoles Incorporating Substituted Thiazolidinone Moieties Detection of 3-4 Methylenedioxyamphetamine from Drug Abuser’s Fingers and Toenails using Liquid Chromatography with Mass Spectroscopy GC-MS Analysis and In-silico Docking Study of Active Antifungal Components of Entada rheedei Spreng. (Seeds)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1