Determination of human monoclonal antibodies nivolumab and relatlimab in opdualag by using the RP-UPLC technique: method development and validation

Sridhar Bonam, T. Siva Rao, K. Rama Srinivas, Suman Pallapati
{"title":"Determination of human monoclonal antibodies nivolumab and relatlimab in opdualag by using the RP-UPLC technique: method development and validation","authors":"Sridhar Bonam, T. Siva Rao, K. Rama Srinivas, Suman Pallapati","doi":"10.1080/22297928.2023.2289515","DOIUrl":null,"url":null,"abstract":"Abstract A fixed combination of Nivolumab and Relatlimab (OPDUALAG) are human monoclonal antibodies (mAb) that are extensively used to treat skin cancer melanoma. The current investigation is to develop a robust, stability-indicating, and rapid method for the simultaneous determination of these two drugs by using the RP-UPLC technique. By utilizing this technique, the final chromatographic conditions were achieved with a Luna C18 column (50 x 2.1 mm, 1.6 μm), and a mobile phase made with acetonitrile and 0.1% formic acid, 6:4 ratio, respectively (Diluted 1.0 mL of Formic acid in 1000 mL of HPLC grade water) by adapting isocratic elution. Both Nivolumab and Relatlimab were detected at 229 nm, and a satisfactory separation was achieved in 3.0 minutes of run time with a flow rate of 0.2 mL/min. The method is linear from 15 - 90 μg/mL for Nivolumab (R2 = 0.9996) and 5 - 30 μg/mL for Relatlimab (R2 = 0.9997). Results of method repeatability for Nivolumab (% RSD=1.3 %) and Relatlimab (% RSD=0.48 %) and intermediate precision Nivolumab (% RSD=1.1 %) and Relatlimab (% RSD=0.48%) were found within acceptable limits. Also, the forced degradation study results show that it is discernible; the degradation products of both drugs were separated from the main peak, which demonstrates the efficiency of the stability-indicating method. So this method works well for routine analysis and stability studies. GRAPHICAL ABSTRACT","PeriodicalId":7793,"journal":{"name":"Analytical Chemistry Letters","volume":"26 1","pages":"528 - 538"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry Letters","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/22297928.2023.2289515","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract A fixed combination of Nivolumab and Relatlimab (OPDUALAG) are human monoclonal antibodies (mAb) that are extensively used to treat skin cancer melanoma. The current investigation is to develop a robust, stability-indicating, and rapid method for the simultaneous determination of these two drugs by using the RP-UPLC technique. By utilizing this technique, the final chromatographic conditions were achieved with a Luna C18 column (50 x 2.1 mm, 1.6 μm), and a mobile phase made with acetonitrile and 0.1% formic acid, 6:4 ratio, respectively (Diluted 1.0 mL of Formic acid in 1000 mL of HPLC grade water) by adapting isocratic elution. Both Nivolumab and Relatlimab were detected at 229 nm, and a satisfactory separation was achieved in 3.0 minutes of run time with a flow rate of 0.2 mL/min. The method is linear from 15 - 90 μg/mL for Nivolumab (R2 = 0.9996) and 5 - 30 μg/mL for Relatlimab (R2 = 0.9997). Results of method repeatability for Nivolumab (% RSD=1.3 %) and Relatlimab (% RSD=0.48 %) and intermediate precision Nivolumab (% RSD=1.1 %) and Relatlimab (% RSD=0.48%) were found within acceptable limits. Also, the forced degradation study results show that it is discernible; the degradation products of both drugs were separated from the main peak, which demonstrates the efficiency of the stability-indicating method. So this method works well for routine analysis and stability studies. GRAPHICAL ABSTRACT
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用 RP-UPLC 技术测定 opdualag 中的人单克隆抗体 nivolumab 和 relatlimab:方法开发与验证
摘要 Nivolumab和Relatlimab(OPDUALAG)是人类单克隆抗体(mAb),被广泛用于治疗皮肤癌黑色素瘤。目前的研究旨在利用 RP-UPLC 技术开发一种稳健、稳定、快速的方法,用于同时测定这两种药物。采用该技术的最终色谱条件为:Luna C18色谱柱(50 x 2.1 mm, 1.6 μm),流动相为乙腈和0.1%甲酸,比例为6:4(在1000 mL HPLC级水中稀释1.0 mL甲酸),采用等度洗脱。Nivolumab和Relatlimab的检测波长均为229 nm,流速为0.2 mL/min,运行时间为3.0分钟,分离效果令人满意。Nivolumab 的线性范围为 15 - 90 μg/mL(R2 = 0.9996),Relatlimab 的线性范围为 5 - 30 μg/mL(R2 = 0.9997)。Nivolumab(RSD%=1.3%)和Relatlimab(RSD%=0.48%)的方法重复性结果以及Nivolumab(RSD%=1.1%)和Relatlimab(RSD%=0.48%)的中间精密度结果均在可接受范围内。此外,强制降解研究结果表明,两种药物的降解产物均可从主峰中分离出来,这表明该稳定性指示方法的效率很高。因此,该方法可用于常规分析和稳定性研究。图表摘要
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.30
自引率
0.00%
发文量
0
期刊最新文献
Simultaneous development and validation of an HPLC-UV method for the analysis of bisphenol A in Moroccan extra virgin olive oil stored in plastic bottles Design of experiment driven ecofriendly RP-HPLC for simultaneous determination of Cilnidipine and Metoprolol succinate Efficient removal of heavy metal ions by modified cellulose prepared from rice husk: Equilibrium isotherms, Kinetics and desorption studies Utilizing central composite design (CCD) in the optimization of new HPLC-PDA method for the assay of daridorexant: Application to the analysis in bulk and tablet dosage forms Chemical characterization of cement samples by radio-analytical methods namely external (in air) PIGE, INAA and ED-XRF for assessing their quality and method validation of radioanalytical techniques
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1