Correlation between Manual Vacuum Aspiration and Endometrial Cell Sampler in Abnormal Uterine Bleeding

Q3 Medicine Siriraj Medical Journal Pub Date : 2023-08-01 DOI:10.33192/smj.v75i8.262259
Korakot Sirimai, Tripop Lertbunnaphong, Catthaleya Suwanthananon, M. Warnnissorn, Nalinee Panichyawat
{"title":"Correlation between Manual Vacuum Aspiration and Endometrial Cell Sampler in Abnormal Uterine Bleeding","authors":"Korakot Sirimai, Tripop Lertbunnaphong, Catthaleya Suwanthananon, M. Warnnissorn, Nalinee Panichyawat","doi":"10.33192/smj.v75i8.262259","DOIUrl":null,"url":null,"abstract":"Objective: Office endometrial biopsy using an endometrial cell sampler is an accepted method of obtaining endometrial tissue for histopathologic evaluation in women with abnormal uterine bleeding (AUB). Manual vacuum aspiration (MVA) is considered an alternative method, but data specific to the use of MVA is limited. This study aimed to evaluate the efficacy of MVA compared to endometrial cell sampler for diagnosing causes of AUB. Materials and Methods: This prospective study enrolled women aged ≥35 years who presented with AUB during August 2015 to June 2016. For each patient, endometrial biopsy using an endometrial cell sampler was first performed followed by MVA. Correlation of endometrial histopathology between methods were analyzed using Kappa statistic. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were evaluated. Results: Of the 162 patients enrolled, the data from 151 women were analyzed. Correspondence of histopathologic finding between tissue obtained from endometrial cell sampler and MVA was 72.8% (Kappa: 0.51). Correspondence of histopathologic finding between tissue obtained from MVA and the final most severe pathology used for treatment decision was 84.1% (Kappa: 0.72). MVA diagnosed all cases of malignancy, but endometrial cell sampler missed one case of malignancy. The overall sensitivity, specificity, PPV, and NPV of MVA was 84.5%, 100%, 100%, and 91.2%, respectively. Conclusion: The histopathologic findings of MVA were in good agreement with those of endometrial cell sampler, and MVA had high accuracy for diagnosing endometrial pathology. MVA is suggested as a reliable alternative procedure for endometrial biopsy in women with AUB.","PeriodicalId":37270,"journal":{"name":"Siriraj Medical Journal","volume":"29 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Siriraj Medical Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33192/smj.v75i8.262259","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Office endometrial biopsy using an endometrial cell sampler is an accepted method of obtaining endometrial tissue for histopathologic evaluation in women with abnormal uterine bleeding (AUB). Manual vacuum aspiration (MVA) is considered an alternative method, but data specific to the use of MVA is limited. This study aimed to evaluate the efficacy of MVA compared to endometrial cell sampler for diagnosing causes of AUB. Materials and Methods: This prospective study enrolled women aged ≥35 years who presented with AUB during August 2015 to June 2016. For each patient, endometrial biopsy using an endometrial cell sampler was first performed followed by MVA. Correlation of endometrial histopathology between methods were analyzed using Kappa statistic. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were evaluated. Results: Of the 162 patients enrolled, the data from 151 women were analyzed. Correspondence of histopathologic finding between tissue obtained from endometrial cell sampler and MVA was 72.8% (Kappa: 0.51). Correspondence of histopathologic finding between tissue obtained from MVA and the final most severe pathology used for treatment decision was 84.1% (Kappa: 0.72). MVA diagnosed all cases of malignancy, but endometrial cell sampler missed one case of malignancy. The overall sensitivity, specificity, PPV, and NPV of MVA was 84.5%, 100%, 100%, and 91.2%, respectively. Conclusion: The histopathologic findings of MVA were in good agreement with those of endometrial cell sampler, and MVA had high accuracy for diagnosing endometrial pathology. MVA is suggested as a reliable alternative procedure for endometrial biopsy in women with AUB.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
异常子宫出血中手动真空抽吸与子宫内膜细胞取样器的相关性
目的:使用子宫内膜细胞取样器进行诊室子宫内膜活检是一种公认的获取子宫内膜组织的方法,用于对异常子宫出血(AUB)妇女进行组织病理学评估。手动真空吸引(MVA)被认为是一种替代方法,但有关 MVA 使用情况的具体数据却很有限。本研究旨在评估 MVA 与子宫内膜细胞取样器相比在诊断 AUB 病因方面的功效。材料与方法:这项前瞻性研究招募了在 2015 年 8 月至 2016 年 6 月期间出现 AUB 的年龄≥35 岁的女性。首先使用子宫内膜细胞取样器对每位患者进行子宫内膜活检,然后进行MVA检查。使用 Kappa 统计学分析了不同方法之间子宫内膜组织病理学的相关性。对敏感性、特异性、阳性预测值(PPV)和阴性预测值(NPV)进行了评估。结果:在登记的 162 名患者中,对 151 名妇女的数据进行了分析。从子宫内膜细胞取样器获得的组织与 MVA 的组织病理学结果的对应性为 72.8%(Kappa:0.51)。从子宫内膜细胞取样器获得的组织与最终用于治疗决策的最严重病理结果之间的组织病理学结果的对应性为 84.1%(Kappa:0.72)。MVA诊断了所有恶性肿瘤病例,但子宫内膜细胞取样器漏诊了一例恶性肿瘤病例。MVA的总体敏感性、特异性、PPV和NPV分别为84.5%、100%、100%和91.2%。结论MVA的组织病理学结果与子宫内膜细胞取样器的组织病理学结果非常吻合,MVA诊断子宫内膜病变的准确性很高。建议将 MVA 作为 AUB 妇女子宫内膜活检的可靠替代方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Siriraj Medical Journal
Siriraj Medical Journal Medicine-Medicine (all)
CiteScore
0.90
自引率
0.00%
发文量
0
审稿时长
8 weeks
期刊最新文献
Incidences, Characteristics, Management and Outcomes of Different Subtypes of Postoperative Delirium in Elderly Patients Admitted to the Surgical Intensive Care Unit: A Secondary Analysis of a Prospective Cohort Study Optimizing Perioperative Care for Elderly Surgical Patients: A Review of Strategies and Evidence-Based Practices Comparison between the Standard Teaching and the Thai Version of Blended Teaching on Basic Airway Management in Siriraj Medical Students Analgesic Efficacy of Ultrasound-guided Fascia Iliaca Compartment Block (FICB) and Outcomes in Preoperative Fast-track Geriatric Patients with Hip Fracture: A Single-center Retrospective Study Effectiveness of Smartphone Applications vs Conventional Care in Warfarin Therapy: A Randomized Controlled Trial on the Time in the Therapeutic Range
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1