An approach to determine nickel in aqueous systems through complexation with a Schiff base based on high‐performance liquid chromatography coupled with photodiode array detector

Asnake Lealem Birhanu, Irshad Mohiuddin
{"title":"An approach to determine nickel in aqueous systems through complexation with a Schiff base based on high‐performance liquid chromatography coupled with photodiode array detector","authors":"Asnake Lealem Birhanu, Irshad Mohiuddin","doi":"10.1002/sscp.202300098","DOIUrl":null,"url":null,"abstract":"This study presents a new and rapid analytical high‐performance liquid chromatography coupled with a photodiode array detector method for determining nickel ion (Ni2+) complex with Schiff base (Z)‐1‐(thiophen‐2‐yl‐methyleneamino) propane‐2‐ol easily. The influence of pH, surfactant, and effect of mobile phase on the formation of the Ni‐(Z)‐1‐(thiophen‐2‐yl‐methyleneamino)propane‐2‐ol complex was studied and optimized. The results showed that the acidic condition (pH = 5) favors the complexation most. Triton X‐100 neutral surfactant was used for dissolving the Ni–complex synthesized. A mobile phase ratio of methanol:acetonitrile:water 70:20:10, v/v/v was taken as optimum. This approach allowed the analysis of Ni2+ ion with the limit of detection of 0.0349 ng/mL over the linear range of (0.1–250 ng/mL) and a relative standard deviation of < 2%. The developed method exhibited remarkable extraction recoveries for Ni2+ in various real water samples (tap water; 98.0%–99.8% and river water; 97.0%–98.7%) and alloys with recoveries of (nichrome; 85.2% and chromel; 88.4%). Moreover, this protocol was also applied for the quantitation of Ni2+ in real sewage samples at a concentration level of 0.256 ng/mL. The outcomes of the present work successfully revealed the apparent superiority of Schiff base (Z)‐1‐(thiophen‐2‐yl‐methyleneamino) propane‐2‐ol toward the practical removal of target Ni2+ under real‐world conditions.","PeriodicalId":508518,"journal":{"name":"SEPARATION SCIENCE PLUS","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-01-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SEPARATION SCIENCE PLUS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/sscp.202300098","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This study presents a new and rapid analytical high‐performance liquid chromatography coupled with a photodiode array detector method for determining nickel ion (Ni2+) complex with Schiff base (Z)‐1‐(thiophen‐2‐yl‐methyleneamino) propane‐2‐ol easily. The influence of pH, surfactant, and effect of mobile phase on the formation of the Ni‐(Z)‐1‐(thiophen‐2‐yl‐methyleneamino)propane‐2‐ol complex was studied and optimized. The results showed that the acidic condition (pH = 5) favors the complexation most. Triton X‐100 neutral surfactant was used for dissolving the Ni–complex synthesized. A mobile phase ratio of methanol:acetonitrile:water 70:20:10, v/v/v was taken as optimum. This approach allowed the analysis of Ni2+ ion with the limit of detection of 0.0349 ng/mL over the linear range of (0.1–250 ng/mL) and a relative standard deviation of < 2%. The developed method exhibited remarkable extraction recoveries for Ni2+ in various real water samples (tap water; 98.0%–99.8% and river water; 97.0%–98.7%) and alloys with recoveries of (nichrome; 85.2% and chromel; 88.4%). Moreover, this protocol was also applied for the quantitation of Ni2+ in real sewage samples at a concentration level of 0.256 ng/mL. The outcomes of the present work successfully revealed the apparent superiority of Schiff base (Z)‐1‐(thiophen‐2‐yl‐methyleneamino) propane‐2‐ol toward the practical removal of target Ni2+ under real‐world conditions.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于高效液相色谱法和光电二极管阵列检测器,通过与希夫碱络合测定水体系中镍含量的方法
本研究提出了一种新型快速分析高效液相色谱-光电二极管阵列检测器法,用于轻松测定镍离子(Ni2+)与席夫碱(Z)-1-(噻吩-2-基-亚甲基氨基)丙烷-2-醇的络合物。研究并优化了 pH 值、表面活性剂和流动相对 Ni-(Z)-1-(噻吩-2-基亚甲基氨基)丙烷-2-醇络合物形成的影响。结果表明,酸性条件(pH = 5)最有利于络合。使用 Triton X-100 中性表面活性剂溶解合成的镍络合物。流动相的最佳比例为甲醇:乙腈:水 70:20:10,v/v/v。采用这种方法分析 Ni2+ 离子,在(0.1-250 ng/mL)线性范围内的检出限为 0.0349 ng/mL,相对标准偏差小于 2%。所开发的方法在各种实际水样(自来水:98.0%-99.8%;河水:97.0%-98.7%)和合金样品(镍铬合金:85.2%;铬合金:88.4%)中的萃取回收率非常高。此外,该方案还被应用于实际污水样本中 Ni2+ 的定量分析,浓度水平为 0.256 ng/mL。本研究成果成功揭示了希夫碱 (Z)-1-(thiophen-2-yl-methyleneamino) propane-2-ol 在实际条件下去除目标 Ni2+ 的明显优越性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Sustainable and Stability Indicating Liquid Chromatography–Mass Spectrometry Method for the Quantitation of Delafloxacin in Pharmaceutical Formulations Direct Quantitation of Poloxamer 188 in Adeno‐Associated Virus Products Using Reversed‐Phase Chromatography With Charged Aerosol Detection Comprehensive Identification of the Chemical Substances in Effective Component Groups of Polygalae Radix Based on Targeted Tandem Mass Spectrometry Analysis Strategy Quality Comparison Between Two Species of Artemisiae Scopariae Herba Through Qualitative Analysis of HPLC Fingerprint and Quantitative Analysis of 12 Representative Constituents Liquid chromatography and liquid chromatography coupled with tandem mass spectrometry studies for the identification and characterization of degradation products of lobeglitazone
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1