Visualization and Identification of Silicone Oil Emulsification Using Dynamic Infrared Confocal Scanning Laser Ophthalmoscopy.

IF 0.5 Q4 OPHTHALMOLOGY Case Reports in Ophthalmology Pub Date : 2024-01-09 eCollection Date: 2024-01-01 DOI:10.1159/000535746
Francisco Javier Valentín-Bravo, Paulo Eduardo Stanga, Sebastián Alfonso Martínez-Tapia, Santiago Mejía-Freire, Sebastian Eduardo Francis Stanga, Ricardo Usategui-Martín, Cristina Andrés-Iglesias, Salvador Pastor-Idoate
{"title":"Visualization and Identification of Silicone Oil Emulsification Using Dynamic Infrared Confocal Scanning Laser Ophthalmoscopy.","authors":"Francisco Javier Valentín-Bravo, Paulo Eduardo Stanga, Sebastián Alfonso Martínez-Tapia, Santiago Mejía-Freire, Sebastian Eduardo Francis Stanga, Ricardo Usategui-Martín, Cristina Andrés-Iglesias, Salvador Pastor-Idoate","doi":"10.1159/000535746","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Silicone oil (SO) is a crucial agent used as an intraocular tamponade in the treatment of complex vitreoretinal diseases. Despite its effectiveness, SO is prone to emulsification, which can lead to significant and sometimes irreversible complications in both the anterior and posterior segments of the eye. The detection and monitoring of SO emulsification are therefore of paramount importance. Traditional imaging modalities have limitations in visualizing SO, leading to the exploration of more advanced imaging techniques. This study introduces the application of dynamic infrared confocal scanning laser ophthalmoscopy (IRcSLO) for this purpose and evaluates its effectiveness.</p><p><strong>Case presentation: </strong>We report on 2 patients who underwent pars plana vitrectomy with subsequent SO injection for the management of retinal detachment. Postsurgery, both patients were imaged using the Heidelberg Retina Tomography Spectralis IRcSLO. The focus was on the visualization of the SO status, including the presence and distribution of emulsified SO droplets. The IRcSLO imaging technique demonstrated its capability to effectively visualize emulsified SO droplets. Interestingly, this was also true for cases where the SO had been removed. The emulsified droplets were observed as micron-sized, spherical entities with a nonuniform distribution throughout the vitreous cavity.</p><p><strong>Conclusion: </strong>Dynamic IRcSLO has proven to be an effective imaging modality for visualizing the emulsification of SO, offering a novel perspective into the characterization of SO droplets. It facilitates the analysis of droplet count, motility, and precise localization within the vitreous cavity. The findings from the case presentations underscore the variability of SO emulsification patterns and the sensitivity of IRcSLO in detecting even minuscule emulsified droplets. This imaging technique has significant potential for future research, particularly in understanding the timing of emulsification, the factors contributing to it, and the development of possible preventive strategies. Additionally, it allows for a more in-depth analysis of the behavior of emulsified SO droplets across different SO viscosities, which could be instrumental in optimizing patient outcomes.</p>","PeriodicalId":9635,"journal":{"name":"Case Reports in Ophthalmology","volume":"15 1","pages":"36-40"},"PeriodicalIF":0.5000,"publicationDate":"2024-01-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10776133/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Case Reports in Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000535746","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Silicone oil (SO) is a crucial agent used as an intraocular tamponade in the treatment of complex vitreoretinal diseases. Despite its effectiveness, SO is prone to emulsification, which can lead to significant and sometimes irreversible complications in both the anterior and posterior segments of the eye. The detection and monitoring of SO emulsification are therefore of paramount importance. Traditional imaging modalities have limitations in visualizing SO, leading to the exploration of more advanced imaging techniques. This study introduces the application of dynamic infrared confocal scanning laser ophthalmoscopy (IRcSLO) for this purpose and evaluates its effectiveness.

Case presentation: We report on 2 patients who underwent pars plana vitrectomy with subsequent SO injection for the management of retinal detachment. Postsurgery, both patients were imaged using the Heidelberg Retina Tomography Spectralis IRcSLO. The focus was on the visualization of the SO status, including the presence and distribution of emulsified SO droplets. The IRcSLO imaging technique demonstrated its capability to effectively visualize emulsified SO droplets. Interestingly, this was also true for cases where the SO had been removed. The emulsified droplets were observed as micron-sized, spherical entities with a nonuniform distribution throughout the vitreous cavity.

Conclusion: Dynamic IRcSLO has proven to be an effective imaging modality for visualizing the emulsification of SO, offering a novel perspective into the characterization of SO droplets. It facilitates the analysis of droplet count, motility, and precise localization within the vitreous cavity. The findings from the case presentations underscore the variability of SO emulsification patterns and the sensitivity of IRcSLO in detecting even minuscule emulsified droplets. This imaging technique has significant potential for future research, particularly in understanding the timing of emulsification, the factors contributing to it, and the development of possible preventive strategies. Additionally, it allows for a more in-depth analysis of the behavior of emulsified SO droplets across different SO viscosities, which could be instrumental in optimizing patient outcomes.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用动态红外共焦扫描激光眼底镜观察和识别硅油乳化。
简介硅酮油(SO)是治疗复杂玻璃体视网膜疾病的重要眼内填塞剂。尽管效果显著,但硅油很容易乳化,这会导致眼球前后节出现严重的、有时甚至是不可逆转的并发症。因此,SO 乳化的检测和监控至关重要。传统的成像模式在观察 SO 方面存在局限性,因此需要探索更先进的成像技术。本研究介绍了动态红外共焦扫描激光眼底镜(IRcSLO)在这方面的应用,并对其效果进行了评估:我们报告了两名接受玻璃体旁切除术并随后注射 SO 以治疗视网膜脱离的患者。手术后,两名患者均使用海德堡视网膜断层扫描 Spectralis IRcSLO 进行了成像。重点是观察 SO 的状态,包括乳化 SO 液滴的存在和分布。IRcSLO 成像技术证明了其有效观察乳化 SO 液滴的能力。有趣的是,在 SO 被清除的情况下也是如此。观察到的乳化液滴为微米大小的球形实体,在玻璃体腔内分布不均匀:动态 IRcSLO 被证明是一种有效的成像模式,可用于观察 SO 的乳化过程,为 SO 液滴的特征描述提供了一个新的视角。它有助于分析玻璃体腔内的液滴数量、流动性和精确定位。病例展示中的发现强调了 SO 乳化模式的可变性,以及 IRcSLO 在检测微小乳化液滴方面的灵敏度。这种成像技术在未来的研究中具有很大的潜力,尤其是在了解乳化的时间、导致乳化的因素以及制定可能的预防策略方面。此外,它还能更深入地分析乳化 SO 液滴在不同 SO 粘度下的行为,有助于优化患者的治疗效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.90
自引率
0.00%
发文量
129
审稿时长
12 weeks
期刊介绍: This peer-reviewed online-only journal publishes original case reports covering the entire spectrum of ophthalmology, including prevention, diagnosis, treatment, toxicities of therapy, supportive care, quality-of-life, and survivorship issues. The submission of negative results is strongly encouraged. The journal will also accept case reports dealing with the use of novel technologies, both in the arena of diagnosis and treatment. Supplementary material is welcomed. The intent of the journal is to provide clinicians and researchers with a tool to disseminate their personal experiences to a wider public as well as to review interesting cases encountered by colleagues all over the world. Universally used terms can be searched across the entire growing collection of case reports, further facilitating the retrieval of specific information. Following the open access principle, the entire contents can be retrieved at no charge, guaranteeing easy access to this valuable source of anecdotal information at all times.
期刊最新文献
Candy Cane Hypopyon Secondary to Intraocular Mantle Cell Lymphoma: A Case Report. Conjunctival Phlyctenule and Nodular Scleritis in a Patient with Previous Herpes Simplex Virus-2 Exposure: Causative Agent or Innocent Bystander? An Unexpected Response of Orbital Retinoblastoma to Inconsistent Systemic Chemotherapy Alone. Erratum. A Case of Conjunctival Melanoma Presenting as a Squamous Cell Carcinoma.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1