Jae Yong Jeong, Dae Young Jun, Young Joon Moon, Dong Hyuk Kang, Hae Do Jung, Seung Hyun Jeon, Joo Yong Lee
{"title":"Training ultrasound-guided percutaneous nephrostomy technique with porcine model.","authors":"Jae Yong Jeong, Dae Young Jun, Young Joon Moon, Dong Hyuk Kang, Hae Do Jung, Seung Hyun Jeon, Joo Yong Lee","doi":"10.4111/icu.20230298","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>There is increasing interest in the use of ultrasound for endoscopic and percutaneous procedures. Access can be achieved without radiation exposure under ultrasound guidance. Our aim was to develop a porcine-based training model for ultrasound-guided percutaneous renal access that could also be personalized to a specific patient.</p><p><strong>Materials and methods: </strong>The Institutional Animal Care and Use Committee of Severance Hospital approved the study protocol. An anesthetized pig was placed in the dorsal lithotomy position. For the nephrostomy puncture, a Chiba biopsy needle with an echo tip was used under ultrasound guidance. Eight residents and three consultants in urology participated. Puncture time was defined as the nephrostomy time to confirm the flow of irrigation via the needle. After training, satisfaction survey results for clinical usability and procedural difficulty were evaluated.</p><p><strong>Results: </strong>The 5-point Likert scale satisfaction survey for clinical usability and procedural difficulty found mean results of 4.64 and 4.09 points, respectively. There were no differences between residents and consultants for either variable. For all participants combined, there was a significant difference for nephrostomy time between the first and second trials (278.8±70.6 s vs. 244.5±47.0 s; p=0.007). The between-trial difference was greater for residents (291.5±71.2 s vs. 259.1±41.9 s; p=0.039). The difference for the consultant was not significant (245.0±69.4 s vs. 205.7±42.5 s; p=0.250).</p><p><strong>Conclusions: </strong>We developed a porcine-based ultrasound-guided nephrostomy puncture training model. Satisfaction survey results indicated high clinical usability and procedural difficulty. For nephrostomy time, the model was more effective for urology residents than for consultants.</p>","PeriodicalId":14522,"journal":{"name":"Investigative and Clinical Urology","volume":"65 1","pages":"62-68"},"PeriodicalIF":2.5000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10789536/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Investigative and Clinical Urology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4111/icu.20230298","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: There is increasing interest in the use of ultrasound for endoscopic and percutaneous procedures. Access can be achieved without radiation exposure under ultrasound guidance. Our aim was to develop a porcine-based training model for ultrasound-guided percutaneous renal access that could also be personalized to a specific patient.
Materials and methods: The Institutional Animal Care and Use Committee of Severance Hospital approved the study protocol. An anesthetized pig was placed in the dorsal lithotomy position. For the nephrostomy puncture, a Chiba biopsy needle with an echo tip was used under ultrasound guidance. Eight residents and three consultants in urology participated. Puncture time was defined as the nephrostomy time to confirm the flow of irrigation via the needle. After training, satisfaction survey results for clinical usability and procedural difficulty were evaluated.
Results: The 5-point Likert scale satisfaction survey for clinical usability and procedural difficulty found mean results of 4.64 and 4.09 points, respectively. There were no differences between residents and consultants for either variable. For all participants combined, there was a significant difference for nephrostomy time between the first and second trials (278.8±70.6 s vs. 244.5±47.0 s; p=0.007). The between-trial difference was greater for residents (291.5±71.2 s vs. 259.1±41.9 s; p=0.039). The difference for the consultant was not significant (245.0±69.4 s vs. 205.7±42.5 s; p=0.250).
Conclusions: We developed a porcine-based ultrasound-guided nephrostomy puncture training model. Satisfaction survey results indicated high clinical usability and procedural difficulty. For nephrostomy time, the model was more effective for urology residents than for consultants.
期刊介绍:
Investigative and Clinical Urology (Investig Clin Urol, ICUrology) is an international, peer-reviewed, platinum open access journal published bimonthly. ICUrology aims to provide outstanding scientific and clinical research articles, that will advance knowledge and understanding of urological diseases and current therapeutic treatments. ICUrology publishes Original Articles, Rapid Communications, Review Articles, Special Articles, Innovations in Urology, Editorials, and Letters to the Editor, with a focus on the following areas of expertise:
• Precision Medicine in Urology
• Urological Oncology
• Robotics/Laparoscopy
• Endourology/Urolithiasis
• Lower Urinary Tract Dysfunction
• Female Urology
• Sexual Dysfunction/Infertility
• Infection/Inflammation
• Reconstruction/Transplantation
• Geriatric Urology
• Pediatric Urology
• Basic/Translational Research
One of the notable features of ICUrology is the application of multimedia platforms facilitating easy-to-access online video clips of newly developed surgical techniques from the journal''s website, by a QR (quick response) code located in the article, or via YouTube. ICUrology provides current and highly relevant knowledge to a broad audience at the cutting edge of urological research and clinical practice.