General Algorithm Applicability in Determining DBS Lead Orientation: Adapting 2D and 3D X-Ray Techniques for SenSightTM Leads.

IF 1.9 4区 医学 Q3 NEUROIMAGING Stereotactic and Functional Neurosurgery Pub Date : 2024-01-01 Epub Date: 2024-01-12 DOI:10.1159/000535716
Stefan Hunsche, Dieter Fedders, Alexandra Hellerbach, Markus Eichner, Jochen Wirths, Till A Dembek, Veerle Visser-Vandewalle, Harald Treuer
{"title":"General Algorithm Applicability in Determining DBS Lead Orientation: Adapting 2D and 3D X-Ray Techniques for SenSightTM Leads.","authors":"Stefan Hunsche, Dieter Fedders, Alexandra Hellerbach, Markus Eichner, Jochen Wirths, Till A Dembek, Veerle Visser-Vandewalle, Harald Treuer","doi":"10.1159/000535716","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>With recent advancements in deep brain stimulation (DBS), directional leads featuring segmented contacts have been introduced, allowing for targeted stimulation of specific brain regions. Given that manufacturers employ diverse markers for lead orientation, our investigation focuses on the adaptability of the 2017 techniques proposed by the Cologne research group for lead orientation determination.</p><p><strong>Methods: </strong>We tailored the two separate 2D and 3D X-ray-based techniques published in 2017 and originally developed for C-shaped markers, to the dual-marker of the Medtronic SenSight™ lead. In a retrospective patient study, we evaluated their feasibility and consistency by comparing the degree of agreement between the two methods.</p><p><strong>Results: </strong>The Bland-Altman plot showed favorable concordance without any noticeable systematic errors. The mean difference was 0.79°, with limits of agreement spanning from 21.4° to -19.8°. The algorithms demonstrated high reliability, evidenced by an intraclass correlation coefficient of 0.99 (p &lt; 0.001).</p><p><strong>Conclusion: </strong>The 2D and 3D algorithms, initially formulated for discerning the circular orientation of a C-shaped marker, were adapted to the marker of the Medtronic SenSight™ lead. Statistical analyses revealed a significant level of agreement between the two methods. Our findings highlight the adaptability of these algorithms to different markers, achievable through both low-dose intraoperative 2D X-ray imaging and standard CT imaging.</p>","PeriodicalId":22078,"journal":{"name":"Stereotactic and Functional Neurosurgery","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10997254/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Stereotactic and Functional Neurosurgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000535716","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/12 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"NEUROIMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: With recent advancements in deep brain stimulation (DBS), directional leads featuring segmented contacts have been introduced, allowing for targeted stimulation of specific brain regions. Given that manufacturers employ diverse markers for lead orientation, our investigation focuses on the adaptability of the 2017 techniques proposed by the Cologne research group for lead orientation determination.

Methods: We tailored the two separate 2D and 3D X-ray-based techniques published in 2017 and originally developed for C-shaped markers, to the dual-marker of the Medtronic SenSight™ lead. In a retrospective patient study, we evaluated their feasibility and consistency by comparing the degree of agreement between the two methods.

Results: The Bland-Altman plot showed favorable concordance without any noticeable systematic errors. The mean difference was 0.79°, with limits of agreement spanning from 21.4° to -19.8°. The algorithms demonstrated high reliability, evidenced by an intraclass correlation coefficient of 0.99 (p < 0.001).

Conclusion: The 2D and 3D algorithms, initially formulated for discerning the circular orientation of a C-shaped marker, were adapted to the marker of the Medtronic SenSight™ lead. Statistical analyses revealed a significant level of agreement between the two methods. Our findings highlight the adaptability of these algorithms to different markers, achievable through both low-dose intraoperative 2D X-ray imaging and standard CT imaging.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于确定 DBS 导联方向的通用算法:将二维和三维 X 射线技术应用于 SenSightTM 导联。
导言:随着脑深部刺激(DBS)技术的不断进步,具有分段触点的定向导线应运而生,可对特定脑区进行定向刺激。鉴于制造商采用不同的标记来确定导线方向,我们的研究重点是科隆研究小组 2017 年提出的导线方向确定技术的适应性:我们将 2017 年发布的两种基于二维和三维 X 射线的独立技术(最初是针对 C 形标记开发的)调整用于美敦力 SenSight™ 导联的双标记。在一项回顾性患者研究中,我们通过比较两种方法的一致程度,评估了它们的可行性和一致性:结果:布兰-阿尔特曼图显示出良好的一致性,没有任何明显的系统误差。平均差异为 0.79°,一致度范围为 21.4°至 -19.8°。算法的可靠性很高,类内相关系数为 0.99(p < 0.001):二维和三维算法最初是为辨别 C 形标记物的圆形方向而制定的,现已适用于美敦力 SenSight™ 导联的标记物。统计分析显示,这两种方法之间的一致性达到了很高的水平。我们的研究结果凸显了这些算法对不同标记物的适应性,可通过术中低剂量二维 X 光成像和标准 CT 成像实现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.80
自引率
0.00%
发文量
33
审稿时长
3 months
期刊介绍: ''Stereotactic and Functional Neurosurgery'' provides a single source for the reader to keep abreast of developments in the most rapidly advancing subspecialty within neurosurgery. Technological advances in computer-assisted surgery, robotics, imaging and neurophysiology are being applied to clinical problems with ever-increasing rapidity in stereotaxis more than any other field, providing opportunities for new approaches to surgical and radiotherapeutic management of diseases of the brain, spinal cord, and spine. Issues feature advances in the use of deep-brain stimulation, imaging-guided techniques in stereotactic biopsy and craniotomy, stereotactic radiosurgery, and stereotactically implanted and guided radiotherapeutics and biologicals in the treatment of functional and movement disorders, brain tumors, and other diseases of the brain. Background information from basic science laboratories related to such clinical advances provides the reader with an overall perspective of this field. Proceedings and abstracts from many of the key international meetings furnish an overview of this specialty available nowhere else. ''Stereotactic and Functional Neurosurgery'' meets the information needs of both investigators and clinicians in this rapidly advancing field.
期刊最新文献
2024 Biennial Meeting of the American Society for Stereotactic and Functional Neurosurgery. Nashville, TN, June 1-4, 2024. 2024 ASSFN Biennial Meeting, Nashville, TN, USA, June 1-4, 2024. What Is "Advanced" Parkinson's Disease? Defining What Determines Medicare Coverage for Deep Brain Stimulation in the USA. Bilateral Anterior Capsulotomy for Treatment-Resistant Obsessive-Compulsive Disorder. A Systematic Review Comparing Radiofrequency versus Focused Ultrasound Pallidotomy in the Treatment of Parkinson's Disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1