A Comparison of Functional Luminal Imaging Probe With High-resolution Manometry, Timed Barium Esophagram, and pH Impedance Testing to Evaluate Functional Luminal Imaging Probe's Diagnostic Capabilities.

IF 2.8 4区 医学 Q2 GASTROENTEROLOGY & HEPATOLOGY Journal of clinical gastroenterology Pub Date : 2024-11-01 Epub Date: 2024-01-15 DOI:10.1097/MCG.0000000000001966
James D Miller, Brendan P Kemple, Joni K Evans, Steven B Clayton
{"title":"A Comparison of Functional Luminal Imaging Probe With High-resolution Manometry, Timed Barium Esophagram, and pH Impedance Testing to Evaluate Functional Luminal Imaging Probe's Diagnostic Capabilities.","authors":"James D Miller, Brendan P Kemple, Joni K Evans, Steven B Clayton","doi":"10.1097/MCG.0000000000001966","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The aims of this study are to determine the functional luminal imaging probe's (FLIP) diagnostic utility by comparing FLIP measurements with results from other esophageal evaluation standards.</p><p><strong>Background: </strong>The FLIP is an esophageal evaluation technique performed at the time of endoscopy. Few studies have evaluated FLIP diagnostic capabilities compared with the established testing techniques, including high-resolution manometry (HRIM), time barium esophagram (TBE), and 24-hour impedance-pH monitoring.</p><p><strong>Patients and methods: </strong>A retrospective review was performed for 413 preintervention patients who underwent FLIP testing during endoscopy. Data from HRIM, 24-hour pH monitoring, and TBE were compared.</p><p><strong>Results: </strong>Abnormal Distensibility Index (DI) was associated with abnormal integrated relaxation pressure (IRP; P = 0.003). Average DI was higher in patients with abnormal IRP (>15 mm Hg) when a hiatal hernia was present ( P = 0.025). The total agreement between correlated diagnoses from FLIP and HRIM was 33.5%. DI was not associated with acid exposure time on pH monitoring. Agreement between FLIP and TBE was 49% with a sensitivity of 98.1% and a specificity of 36.5%. A 60 mL distension had a significantly lower detection rate than 40 mL and 50 mL for active peristalsis and was unaffected by pressure ( P < 0.05).</p><p><strong>Conclusions: </strong>FLIP as an adjunct to HRIM is supported by strong metric correlation. FLIP was not correlated to pH monitoring findings, suggesting FLIP is not useful in reflux assessment. The agreement between FLIP and TBE was lower than in previous studies. Hiatal hernia impacted the normality between DI and IRP, not between FLIP and TBE. We suggest analyzing peristaltic patterns on panometry at all fill volumes to optimize detection.</p>","PeriodicalId":15457,"journal":{"name":"Journal of clinical gastroenterology","volume":" ","pages":"981-988"},"PeriodicalIF":2.8000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of clinical gastroenterology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MCG.0000000000001966","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/15 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: The aims of this study are to determine the functional luminal imaging probe's (FLIP) diagnostic utility by comparing FLIP measurements with results from other esophageal evaluation standards.

Background: The FLIP is an esophageal evaluation technique performed at the time of endoscopy. Few studies have evaluated FLIP diagnostic capabilities compared with the established testing techniques, including high-resolution manometry (HRIM), time barium esophagram (TBE), and 24-hour impedance-pH monitoring.

Patients and methods: A retrospective review was performed for 413 preintervention patients who underwent FLIP testing during endoscopy. Data from HRIM, 24-hour pH monitoring, and TBE were compared.

Results: Abnormal Distensibility Index (DI) was associated with abnormal integrated relaxation pressure (IRP; P = 0.003). Average DI was higher in patients with abnormal IRP (>15 mm Hg) when a hiatal hernia was present ( P = 0.025). The total agreement between correlated diagnoses from FLIP and HRIM was 33.5%. DI was not associated with acid exposure time on pH monitoring. Agreement between FLIP and TBE was 49% with a sensitivity of 98.1% and a specificity of 36.5%. A 60 mL distension had a significantly lower detection rate than 40 mL and 50 mL for active peristalsis and was unaffected by pressure ( P < 0.05).

Conclusions: FLIP as an adjunct to HRIM is supported by strong metric correlation. FLIP was not correlated to pH monitoring findings, suggesting FLIP is not useful in reflux assessment. The agreement between FLIP and TBE was lower than in previous studies. Hiatal hernia impacted the normality between DI and IRP, not between FLIP and TBE. We suggest analyzing peristaltic patterns on panometry at all fill volumes to optimize detection.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
功能性腔隙成像探针与高分辨率测压法、定时食道钡餐和 pH 值阻抗测试的比较,以评估功能性腔隙成像探针的诊断能力。
研究目的本研究旨在通过比较功能性管腔成像探针(FLIP)的测量结果和其他食管评估标准的结果,确定功能性管腔成像探针(FLIP)的诊断效用:背景:FLIP 是一种在内镜检查时进行的食管评估技术。背景:FLIP 是一种在内镜检查时进行的食管评估技术,很少有研究将 FLIP 诊断能力与高分辨率测压(HRIM)、时间食管钡餐(TBE)和 24 小时阻抗-pH 监测等成熟的检测技术进行比较评估:对 413 名在内窥镜检查期间接受 FLIP 测试的干预前患者进行了回顾性审查。比较了 HRIM、24 小时 pH 值监测和 TBE 的数据:结果:胀气指数(DI)异常与综合松弛压(IRP)异常有关,P = 0.003。当存在裂孔疝时,综合松弛压异常(>15 毫米汞柱)患者的平均胀气指数更高(P = 0.025)。FLIP 和 HRIM 的相关诊断之间的总吻合率为 33.5%。DI 与 pH 值监测中的酸暴露时间无关。FLIP 和 TBE 的一致性为 49%,灵敏度为 98.1%,特异性为 36.5%。60毫升胀气对活跃蠕动的检出率明显低于40毫升和50毫升,且不受压力影响(P < 0.05):结论:FLIP作为HRIM的辅助指标具有很强的相关性。FLIP与pH值监测结果不相关,这表明FLIP在反流评估中并不实用。FLIP 与 TBE 之间的一致性低于之前的研究。膈疝影响了 DI 和 IRP 之间的正常性,但 FLIP 和 TBE 之间的正常性不受影响。我们建议在所有充气量下分析平流计的蠕动模式,以优化检测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of clinical gastroenterology
Journal of clinical gastroenterology 医学-胃肠肝病学
CiteScore
5.60
自引率
3.40%
发文量
339
审稿时长
3-8 weeks
期刊介绍: Journal of Clinical Gastroenterology gathers the world''s latest, most relevant clinical studies and reviews, case reports, and technical expertise in a single source. Regular features include cutting-edge, peer-reviewed articles and clinical reviews that put the latest research and development into the context of your practice. Also included are biographies, focused organ reviews, practice management, and therapeutic recommendations.
期刊最新文献
Association Between Different Types of Physical Activity and Hepatic Steatosis and Liver Fibrosis: A Cross-Sectional Study Based on NHANES. Efficacy of Endoscopic Therapy in Symptomatic Pancreatic Divisum: A Systematic Review and Meta-analysis. Outcomes of ERCP in Patients With Cystic Fibrosis: A Nationwide Inpatient Assessment. Satisfaction With and Adherence to Off-Label Corticosteroids in Adolescents and Adults With Eosinophilic Esophagitis: Results of a Web-Based Survey in the United States. Do Patients With NASH-related Cirrhosis Have Better Overall Survival Compared With Other Etiologies of Cirrhosis? A Population-based Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1