Novel upper gastrointestinal bleeding sensor capsule: a first human feasibility and safety trial.

IF 2.1 Q3 GASTROENTEROLOGY & HEPATOLOGY Clinical Endoscopy Pub Date : 2024-03-01 Epub Date: 2024-01-17 DOI:10.5946/ce.2023.111
Lukas Bajer, Marvin Ryou, Christopher C Thompson, Pavel Drastich
{"title":"Novel upper gastrointestinal bleeding sensor capsule: a first human feasibility and safety trial.","authors":"Lukas Bajer, Marvin Ryou, Christopher C Thompson, Pavel Drastich","doi":"10.5946/ce.2023.111","DOIUrl":null,"url":null,"abstract":"<p><strong>Background/aims: </strong>Upper gastrointestinal bleeding (UGIB) is the most common GI condition requiring hospitalization, and can be diagnosed by direct visualization. The present study aimed to evaluate the safety and feasibility of using the PillSense system (EnteraSense Ltd.), a novel diagnostic tool designed for the rapid in vivo detection of UGIB, in human volunteers.</p><p><strong>Methods: </strong>In the present study, 10 volunteers swallowed a PillSense capsule, followed by 2 servings of an autologous blood preparation. Participants were monitored for capsule passage, overall tolerability of the procedure, and adverse events.</p><p><strong>Results: </strong>The procedure was completed per the protocol established in the present study in 9/10 cases. In 9 of the subjects, after capsule ingestion, the device indicated the absence of blood with sensor output values of 1. After the ingestion of the first blood mixture, the sensor outputs of all devices increased from 2.8 to 4, indicating that each camera detected blood. The sensor output remained within that range after the ingestion of the second mixture; however, in one case, the baseline capsule signal was positive, because of a preexisting condition. The passage of the capsule was verified in all patients, and no adverse events were reported.</p><p><strong>Conclusion: </strong>The first trial of the PillSense system in human subjects demonstrated the feasibility, safety, and tolerability of utilizing this product as a novel, noninvasive, and easy-to-use triage tool for the diagnosis of patients suspected of having UGIB.</p>","PeriodicalId":10351,"journal":{"name":"Clinical Endoscopy","volume":" ","pages":"203-208"},"PeriodicalIF":2.1000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10984735/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Endoscopy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5946/ce.2023.111","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/17 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background/aims: Upper gastrointestinal bleeding (UGIB) is the most common GI condition requiring hospitalization, and can be diagnosed by direct visualization. The present study aimed to evaluate the safety and feasibility of using the PillSense system (EnteraSense Ltd.), a novel diagnostic tool designed for the rapid in vivo detection of UGIB, in human volunteers.

Methods: In the present study, 10 volunteers swallowed a PillSense capsule, followed by 2 servings of an autologous blood preparation. Participants were monitored for capsule passage, overall tolerability of the procedure, and adverse events.

Results: The procedure was completed per the protocol established in the present study in 9/10 cases. In 9 of the subjects, after capsule ingestion, the device indicated the absence of blood with sensor output values of 1. After the ingestion of the first blood mixture, the sensor outputs of all devices increased from 2.8 to 4, indicating that each camera detected blood. The sensor output remained within that range after the ingestion of the second mixture; however, in one case, the baseline capsule signal was positive, because of a preexisting condition. The passage of the capsule was verified in all patients, and no adverse events were reported.

Conclusion: The first trial of the PillSense system in human subjects demonstrated the feasibility, safety, and tolerability of utilizing this product as a novel, noninvasive, and easy-to-use triage tool for the diagnosis of patients suspected of having UGIB.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
新型上消化道出血传感器胶囊:首次人体可行性和安全性试验。
背景/目的:上消化道出血(UGIB)是最常见的需要住院治疗的消化道疾病,可通过直接观察进行诊断。本研究旨在评估在人类志愿者中使用 PillSense 系统(EnteraSense 有限公司)的安全性和可行性:在本研究中,10 名志愿者吞服了一颗 PillSense 胶囊,然后服用了两份自体血液制剂。对参与者的胶囊通过情况、整个过程的耐受性以及不良反应进行了监测:结果:9/10 的受试者按照本研究制定的方案完成了实验。其中 9 名受试者在吃下胶囊后,设备显示没有血液,传感器输出值为 1。摄入第二种混合物后,传感器输出仍保持在这一范围内;但有一次,由于预先存在的情况,胶囊基线信号为正。所有患者的胶囊通过情况都得到了验证,未报告任何不良事件:PillSense 系统的首次人体试验表明,将该产品作为一种新型、无创、易用的分诊工具用于诊断疑似 UGIB 患者是可行的、安全的、可耐受的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Clinical Endoscopy
Clinical Endoscopy GASTROENTEROLOGY & HEPATOLOGY-
CiteScore
4.40
自引率
8.00%
发文量
95
审稿时长
26 weeks
期刊最新文献
Endoscopic vacuum therapy for gastrointestinal transmural defects: a literature review. Effectiveness of a novel ex vivo training model for gastric endoscopic submucosal dissection training: a prospective observational study conducted at a single center in Japan. Microbiological surveillance result of endoscopes after INTERCEPT Foam Spray: a quasi-experimental pilot study in Singapore. Technical challenges and safety of prophylactic gallbladder stenting with metallic biliary stenting. The impact of linked color imaging on adenoma detection rate in colonoscopy: a systematic review and meta-analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1