12-Month Real-Life Efficacy of the MiniMed 780G Advanced Closed-Loop System in Patients Living with Type 1 Diabetes: A French Observational, Retrospective, Multicentric Study.

IF 5.7 2区 医学 Q1 ENDOCRINOLOGY & METABOLISM Diabetes technology & therapeutics Pub Date : 2024-06-01 Epub Date: 2024-02-07 DOI:10.1089/dia.2023.0414
Sandrine Lablanche, Johanna Delagenière, Manon Jalbert, Emmanuel Sonnet, Muriel Benichou, Nathalie Arnold, Anne Spiteri, Jean-Philippe Le Berre, Eric Renard, Nicolas Chevalier, Sophie Borot, Elisabeth Bonnemaison, Christine Coffin, Marie-Pierre Teissier, Pierre Yves Benhamou, Jean-Christian Borel, Alfred Penfornis, Michael Joubert, Laurence Kessler
{"title":"12-Month Real-Life Efficacy of the MiniMed 780G Advanced Closed-Loop System in Patients Living with Type 1 Diabetes: A French Observational, Retrospective, Multicentric Study.","authors":"Sandrine Lablanche, Johanna Delagenière, Manon Jalbert, Emmanuel Sonnet, Muriel Benichou, Nathalie Arnold, Anne Spiteri, Jean-Philippe Le Berre, Eric Renard, Nicolas Chevalier, Sophie Borot, Elisabeth Bonnemaison, Christine Coffin, Marie-Pierre Teissier, Pierre Yves Benhamou, Jean-Christian Borel, Alfred Penfornis, Michael Joubert, Laurence Kessler","doi":"10.1089/dia.2023.0414","DOIUrl":null,"url":null,"abstract":"<p><p><b><i>Aim:</i></b> To evaluate the evolution of glycemic outcomes in patients living with type 1 diabetes (T1D) after 1 year of use of the MiniMed 780G advanced hybrid closed-loop (AHCL) system. <b><i>Methods:</i></b> We conducted an observational, retrospective, multicentric study in 20 centers in France. The primary objective was to evaluate the improvement in glycemic control after 1-year use of AHCL. The primary endpoint was the variation of time in range (TIR) between pre-AHCL and after 1-year use of AHCL. Secondary objectives were to analyze the glycemic outcomes after 3, 6, and 12 months of AHCL use, the safety, and the long-term observance of AHCL. <b><i>Results:</i></b> Two hundred twenty patients were included, and 200 were analyzed for the primary endpoint. 92.7% of patients continued to use AHCL. After 1 year of use of AHCL, TIR was 72.5% ± 10.6% (+9.1%; 95% confidence interval [CI] [7.6-10.5] compared to pre-AHCL initiation, <i>P</i> < 0.001), HbA1c 7.1% ± 0.7% (-0.5%; 95% CI [-0.6 to -0.4]; <i>P</i> < 0.001), time below range 2.0% [1.0; 3.0] (0.0% [-2.0; 0.0], <i>P</i> < 0.001), and time above range 24.8% ± 10.9% (-7.3%; 95% CI [-8.8 to -5.7]; <i>P</i> < 0.001). More patients achieved the glycemic treatment goals of HbA1c <7.0% (45.1% vs. 18.1%, <i>P</i> < 0.001) and TIR >70% (59.0% vs. 29.5% <i>P</i> < 0.001) when compared with pre-AHCL. Five patients experienced severe hypoglycemia events and two patients experienced ketoacidosis. <b><i>Conclusion:</i></b> After 1 year of use of AHCL, people living with T1D safely improved their glucose control and a higher proportion of them achieved optimal glycemic control.</p>","PeriodicalId":11159,"journal":{"name":"Diabetes technology & therapeutics","volume":" ","pages":"426-432"},"PeriodicalIF":5.7000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetes technology & therapeutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/dia.2023.0414","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/7 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: To evaluate the evolution of glycemic outcomes in patients living with type 1 diabetes (T1D) after 1 year of use of the MiniMed 780G advanced hybrid closed-loop (AHCL) system. Methods: We conducted an observational, retrospective, multicentric study in 20 centers in France. The primary objective was to evaluate the improvement in glycemic control after 1-year use of AHCL. The primary endpoint was the variation of time in range (TIR) between pre-AHCL and after 1-year use of AHCL. Secondary objectives were to analyze the glycemic outcomes after 3, 6, and 12 months of AHCL use, the safety, and the long-term observance of AHCL. Results: Two hundred twenty patients were included, and 200 were analyzed for the primary endpoint. 92.7% of patients continued to use AHCL. After 1 year of use of AHCL, TIR was 72.5% ± 10.6% (+9.1%; 95% confidence interval [CI] [7.6-10.5] compared to pre-AHCL initiation, P < 0.001), HbA1c 7.1% ± 0.7% (-0.5%; 95% CI [-0.6 to -0.4]; P < 0.001), time below range 2.0% [1.0; 3.0] (0.0% [-2.0; 0.0], P < 0.001), and time above range 24.8% ± 10.9% (-7.3%; 95% CI [-8.8 to -5.7]; P < 0.001). More patients achieved the glycemic treatment goals of HbA1c <7.0% (45.1% vs. 18.1%, P < 0.001) and TIR >70% (59.0% vs. 29.5% P < 0.001) when compared with pre-AHCL. Five patients experienced severe hypoglycemia events and two patients experienced ketoacidosis. Conclusion: After 1 year of use of AHCL, people living with T1D safely improved their glucose control and a higher proportion of them achieved optimal glycemic control.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Minimed 780G 高级闭环系统对 1 型糖尿病患者 12 个月的实际疗效:一项法国观察性、回顾性、多中心研究。
目的:评估使用 Minimed 780G 高级混合闭环系统(AHCL)一年后 1 型糖尿病(T1D)患者的血糖变化情况:我们在法国的 20 个中心开展了一项观察性、回顾性、多中心研究。主要目的是评估使用 AHCL 一年后血糖控制的改善情况。主要终点是使用 AHCL 前和使用 AHCL 一年后 TIR 的变化。次要目标是分析使用 AHCL 3、6 和 12 个月后的血糖结果、安全性以及长期坚持使用 AHCL 的情况。92.7%的患者继续使用AHCL。使用AHCL一年后,TIR为72.5 ± 10.6% (+ 9.1 %; IC95 [7.6; 10.5],与开始使用AHCL前相比,p70% (59.0% vs. 29.5% p 结论:AHCL的使用率和长期观察率均高于AHCL:使用AHCL一年后,T1D患者的血糖控制得到了安全改善,更高的比例实现了最佳血糖控制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Diabetes technology & therapeutics
Diabetes technology & therapeutics 医学-内分泌学与代谢
CiteScore
10.60
自引率
14.80%
发文量
145
审稿时长
3-8 weeks
期刊介绍: Diabetes Technology & Therapeutics is the only peer-reviewed journal providing healthcare professionals with information on new devices, drugs, drug delivery systems, and software for managing patients with diabetes. This leading international journal delivers practical information and comprehensive coverage of cutting-edge technologies and therapeutics in the field, and each issue highlights new pharmacological and device developments to optimize patient care.
期刊最新文献
A Telehealth Program Using Continuous Glucose Monitoring and a Connected Insulin Pen Cap in Nursing Homes for Older Adults with Insulin-Treated Diabetes: The Trescasas Study. Comment on Preechasuk et al: Switching from Intermittently-Scanned Continuous Glucose Monitoring to Real-Time Continuous Glucose Monitoring with a Predictive Urgent Low Soon Alert Reduces Exposure to Hypoglycemia. The Impact of Public Policy on Equitable Access to Technology for Children and Youth Living with Type 1 Diabetes in British Columbia, Canada. Randomized, Crossover Trial of Control-IQ Technology with a Lower Treatment Range and a Modified Meal Bolus Module in Adults, Adolescents, Children, and Preschoolers with Varying Levels of Baseline Glycemic Control. Impact of Continuous Glucose Monitoring Versus Blood Glucose Monitoring to Support a Carbohydrate-Restricted Nutrition Intervention in People with Type 2 Diabetes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1