Sang Mee Hwang, Inseong Oh, Seok Ryun Kwon, Jee-Soo Lee, Moon-Woo Seong
{"title":"Comparison of Measurable Residual Disease in Pediatric B-Lymphoblastic Leukemia Using Multiparametric Flow Cytometry and Next-Generation Sequencing.","authors":"Sang Mee Hwang, Inseong Oh, Seok Ryun Kwon, Jee-Soo Lee, Moon-Woo Seong","doi":"10.3343/alm.2023.0412","DOIUrl":null,"url":null,"abstract":"<p><p>Measurable residual disease (MRD) testing, a standard procedure in B-lymphoblastic leukemia (B-ALL) diagnostics, is assessed using multiparametric flow cytometry (MFC) and next-generation sequencing (NGS) analysis of immunoglobulin gene rearrangements. We evaluated the concordance between eight-color, two-tube MFC-MRD the LymphoTrack NGS-MRD assays using 139 follow-up samples from 54 pediatric patients with B-ALL. We also assessed the effect of hemodilution in MFC-MRD assays. The MRD-concordance rate was 79.9% (N=111), with 25 (18.0%) and 3 (2.2%) samples testing positive only by NGS-MRD (MFC<sup>-</sup>NGS<sup>+</sup>MRD) and MFC-MRD (MFC<sup>+</sup>NGS<sup>-</sup>MRD), respectively. We found a significant correlation in MRD values from total nucleated cells between the two methods (r=0.736 [0.647-0.806], <i>P</i><0.001). The median MRD value of MFC<sup>-</sup>NGS<sup>+</sup>MRD samples was estimated to be 0.0012% (0.0001%-0.0263%) using the NGS-MRD assays. Notably, 14.3% of MFC<sup>-</sup>NGS<sup>+</sup>MRD samples showed NGS-MRD values below the limit of detection in the MFC-MRD assays. The percentages of hematogones detected in MFC-MRD assays significantly differed between the discordant and concordant cases (<i>P</i><0.001). MFC and NGS-MRD assays showed relatively high concordance and correlation in MRD assessment, whereas the NGS-MRD assay detected MRD more frequently than the MFC-MRD assay in pediatric B-ALL. Evaluating the hematogone percentages can aid in assessing the impact of sample hemodilution.</p>","PeriodicalId":8421,"journal":{"name":"Annals of Laboratory Medicine","volume":" ","pages":"354-358"},"PeriodicalIF":4.0000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10961625/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Laboratory Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3343/alm.2023.0412","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/19 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Measurable residual disease (MRD) testing, a standard procedure in B-lymphoblastic leukemia (B-ALL) diagnostics, is assessed using multiparametric flow cytometry (MFC) and next-generation sequencing (NGS) analysis of immunoglobulin gene rearrangements. We evaluated the concordance between eight-color, two-tube MFC-MRD the LymphoTrack NGS-MRD assays using 139 follow-up samples from 54 pediatric patients with B-ALL. We also assessed the effect of hemodilution in MFC-MRD assays. The MRD-concordance rate was 79.9% (N=111), with 25 (18.0%) and 3 (2.2%) samples testing positive only by NGS-MRD (MFC-NGS+MRD) and MFC-MRD (MFC+NGS-MRD), respectively. We found a significant correlation in MRD values from total nucleated cells between the two methods (r=0.736 [0.647-0.806], P<0.001). The median MRD value of MFC-NGS+MRD samples was estimated to be 0.0012% (0.0001%-0.0263%) using the NGS-MRD assays. Notably, 14.3% of MFC-NGS+MRD samples showed NGS-MRD values below the limit of detection in the MFC-MRD assays. The percentages of hematogones detected in MFC-MRD assays significantly differed between the discordant and concordant cases (P<0.001). MFC and NGS-MRD assays showed relatively high concordance and correlation in MRD assessment, whereas the NGS-MRD assay detected MRD more frequently than the MFC-MRD assay in pediatric B-ALL. Evaluating the hematogone percentages can aid in assessing the impact of sample hemodilution.
期刊介绍:
Annals of Laboratory Medicine is the official journal of Korean Society for Laboratory Medicine. The journal title has been recently changed from the Korean Journal of Laboratory Medicine (ISSN, 1598-6535) from the January issue of 2012. The JCR 2017 Impact factor of Ann Lab Med was 1.916.