Advances in Technical Assessment of Spiral Inertial Microfluidic Devices Toward Bioparticle Separation and Profiling: A Critical Review

IF 5.5 3区 工程技术 Q1 BIOCHEMICAL RESEARCH METHODS BioChip Journal Pub Date : 2024-01-22 DOI:10.1007/s13206-023-00131-1
Mahsa Bagi, Fatemeh Amjad, Seyed Majid Ghoreishian, Somayeh Sohrabi Shahsavari, Yun Suk Huh, Mostafa Keshavarz Moraveji, Sirivatch Shimpalee
{"title":"Advances in Technical Assessment of Spiral Inertial Microfluidic Devices Toward Bioparticle Separation and Profiling: A Critical Review","authors":"Mahsa Bagi, Fatemeh Amjad, Seyed Majid Ghoreishian, Somayeh Sohrabi Shahsavari, Yun Suk Huh, Mostafa Keshavarz Moraveji, Sirivatch Shimpalee","doi":"10.1007/s13206-023-00131-1","DOIUrl":null,"url":null,"abstract":"<p>Separation of micro- and nano-sized bioparticles is essential for efficient diagnostics, chemical and biological analyses, drug development, food and chemical processing, and environmental monitoring. However, most of the currently available bio-separation techniques are based on the membrane filtration approach, whose efficiency is restricted by membrane-related disadvantages, including pore size, surface charge density, and biocompatibility, which results in a reduction in the isolation resolution. To address these issues, till now, many microfluidic devices have been developed for particle/cell profiling due to their excellent sensitivity and specificity, less sample consumption, shortened processing time, and high throughput features. Of the various microfluidic systems, the spiral inertial microfluidic technique has recently attracted attention as an innovative strategy and advanced cutting-edge technology toward bioparticle separation. Depending on the needs of the microfluidic device, the spiral inertial chip can be customized to separate bioparticles owing to their sizes and different shapes. In this review, we discuss the kinematics of microchannel particle separation mechanisms, recent developments in the inertial microfluidic device realm, and their applications for the separation of several types of bioparticles, including blood cells, stem cells, sperm cells, pathogens, and algae. Finally, we highlight challenges and economical perspectives associated with guidelines for further development of spiral inertial microfluidic devices in the future.</p><h3 data-test=\"abstract-sub-heading\">Graphical Abstract</h3>\n","PeriodicalId":8768,"journal":{"name":"BioChip Journal","volume":null,"pages":null},"PeriodicalIF":5.5000,"publicationDate":"2024-01-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BioChip Journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s13206-023-00131-1","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

Separation of micro- and nano-sized bioparticles is essential for efficient diagnostics, chemical and biological analyses, drug development, food and chemical processing, and environmental monitoring. However, most of the currently available bio-separation techniques are based on the membrane filtration approach, whose efficiency is restricted by membrane-related disadvantages, including pore size, surface charge density, and biocompatibility, which results in a reduction in the isolation resolution. To address these issues, till now, many microfluidic devices have been developed for particle/cell profiling due to their excellent sensitivity and specificity, less sample consumption, shortened processing time, and high throughput features. Of the various microfluidic systems, the spiral inertial microfluidic technique has recently attracted attention as an innovative strategy and advanced cutting-edge technology toward bioparticle separation. Depending on the needs of the microfluidic device, the spiral inertial chip can be customized to separate bioparticles owing to their sizes and different shapes. In this review, we discuss the kinematics of microchannel particle separation mechanisms, recent developments in the inertial microfluidic device realm, and their applications for the separation of several types of bioparticles, including blood cells, stem cells, sperm cells, pathogens, and algae. Finally, we highlight challenges and economical perspectives associated with guidelines for further development of spiral inertial microfluidic devices in the future.

Graphical Abstract

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
螺旋惯性微流体设备在生物颗粒分离和剖析方面的技术评估进展:批判性评论
微米级和纳米级生物颗粒的分离对于高效诊断、化学和生物分析、药物开发、食品和化学加工以及环境监测至关重要。然而,目前大多数可用的生物分离技术都基于膜过滤方法,其效率受到与膜有关的缺点的限制,包括孔径、表面电荷密度和生物相容性,从而导致分离分辨率降低。为了解决这些问题,迄今为止,许多微流控设备因其卓越的灵敏度和特异性、较少的样品消耗、较短的处理时间和高通量等特点,已被开发用于颗粒/细胞图谱分析。在各种微流控系统中,螺旋惯性微流控技术作为一种创新策略和先进的生物颗粒分离前沿技术,最近引起了人们的关注。根据微流控装置的需要,螺旋惯性芯片可以根据生物颗粒的大小和不同形状进行定制,以分离生物颗粒。在这篇综述中,我们将讨论微通道颗粒分离机制的运动学、惯性微流体设备领域的最新发展,以及它们在分离血细胞、干细胞、精子细胞、病原体和藻类等几类生物颗粒中的应用。最后,我们强调了与螺旋惯性微流控装置未来进一步发展指南相关的挑战和经济前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
BioChip Journal
BioChip Journal 生物-生化研究方法
CiteScore
7.70
自引率
16.30%
发文量
47
审稿时长
6-12 weeks
期刊介绍: BioChip Journal publishes original research and reviews in all areas of the biochip technology in the following disciplines, including protein chip, DNA chip, cell chip, lab-on-a-chip, bio-MEMS, biosensor, micro/nano mechanics, microfluidics, high-throughput screening technology, medical science, genomics, proteomics, bioinformatics, medical diagnostics, environmental monitoring and micro/nanotechnology. The Journal is committed to rapid peer review to ensure the publication of highest quality original research and timely news and review articles.
期刊最新文献
Advancing Blood–Brain Barrier-on-a-Chip Models Through Numerical Simulations Advanced Microfluidic Platform for Tumor Spheroid Formation and Cultivation Fabricated from OSTE+ Polymer Classification of DNA Mixtures by Nanoelectrokinetic Driftless Preconcentration Fabrication of Nephrotoxic Model by Kidney-on-a-Chip Implementing Renal Proximal Tubular Function In Vitro Development of Multi-HRP-Conjugated Branched PEI/Antibody-Functionalized Gold Nanoparticles for Ultra-Sensitive ELISA
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1