Simultaneous determination of five carbapenems, highly polar antibiotics, in milk by LC-MS/MS.

Yumi Ohba, Hiroshi Hayashi, Maki Kanda, Chieko Nagano, Souichi Yoshikawa, Takayuki Nakajima, Yoko Matsushima, Hiroshi Koike, Momoka Hayashi, Tomoko Yokoyama, Takeo Sasamoto
{"title":"Simultaneous determination of five carbapenems, highly polar antibiotics, in milk by LC-MS/MS.","authors":"Yumi Ohba, Hiroshi Hayashi, Maki Kanda, Chieko Nagano, Souichi Yoshikawa, Takayuki Nakajima, Yoko Matsushima, Hiroshi Koike, Momoka Hayashi, Tomoko Yokoyama, Takeo Sasamoto","doi":"10.1080/19440049.2023.2300338","DOIUrl":null,"url":null,"abstract":"<p><p>The simultaneous determination of five carbapenems (biapenem, doripenem, ertapenem, imipenem, and meropenem) in raw and pasteurised bovine milk samples using LC-MS/MS was achieved and validated. Chromatographic separation was conducted on an InertSustain<sup>®</sup> AQ-C18 column using 0.1% formic acid in water and acetonitrile as the mobile phase. Target compounds were extracted using acetonitrile/water (20:80, v/v). After the removal of lipids with acetonitrile-saturated hexane, the dissolved protein was denatured with acetic acid. A portion of the supernatant was passed through an Oasis<sup>®</sup> PRiME HLB cartridge to remove the matrix. This novel method was validated in accordance with the Japanese validation guidelines and exhibited good trueness, ranging from 86.3% to 96.2%, using matrix-matched calibration curves. The relative standard deviation of repeatability ranged from 1.0% to 6.3%, and that of within-laboratory reproducibility ranged from 1.6% to 7.1%. The limit of quantification was 1.0 µg kg<sup>-1</sup> for all analytes. None of the 60 milk samples commercially available in Tokyo contained any analytes. This novel method exhibited high-quality performance and can easily be implemented for the routine monitoring of carbapenems, which are highly polar antibiotics in milk.</p>","PeriodicalId":12295,"journal":{"name":"Food Additives and Contaminants Part A-chemistry Analysis Control Exposure & Risk Assessment","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Food Additives and Contaminants Part A-chemistry Analysis Control Exposure & Risk Assessment","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1080/19440049.2023.2300338","RegionNum":3,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, APPLIED","Score":null,"Total":0}
引用次数: 0

Abstract

The simultaneous determination of five carbapenems (biapenem, doripenem, ertapenem, imipenem, and meropenem) in raw and pasteurised bovine milk samples using LC-MS/MS was achieved and validated. Chromatographic separation was conducted on an InertSustain® AQ-C18 column using 0.1% formic acid in water and acetonitrile as the mobile phase. Target compounds were extracted using acetonitrile/water (20:80, v/v). After the removal of lipids with acetonitrile-saturated hexane, the dissolved protein was denatured with acetic acid. A portion of the supernatant was passed through an Oasis® PRiME HLB cartridge to remove the matrix. This novel method was validated in accordance with the Japanese validation guidelines and exhibited good trueness, ranging from 86.3% to 96.2%, using matrix-matched calibration curves. The relative standard deviation of repeatability ranged from 1.0% to 6.3%, and that of within-laboratory reproducibility ranged from 1.6% to 7.1%. The limit of quantification was 1.0 µg kg-1 for all analytes. None of the 60 milk samples commercially available in Tokyo contained any analytes. This novel method exhibited high-quality performance and can easily be implemented for the routine monitoring of carbapenems, which are highly polar antibiotics in milk.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用 LC-MS/MS 同时测定牛奶中的五种碳青霉烯类极性抗生素。
采用 LC-MS/MS 法同时测定了生牛乳和巴氏杀菌牛乳样品中的五种碳青霉烯类药物(比阿培南、多立培南、厄他培南、亚胺培南和美罗培南),并进行了验证。色谱分离采用 InertSustain® AQ-C18 色谱柱,以 0.1% 甲酸水溶液和乙腈为流动相。目标化合物用乙腈/水(20:80,v/v)提取。用饱和乙腈的正己烷去除脂质后,用乙酸使溶解的蛋白质变性。部分上清液通过 Oasis® PRiME HLB 滤芯去除基质。根据日本的验证指南对该新型方法进行了验证,结果表明,使用基质匹配校准曲线,该方法的准确度在 86.3% 至 96.2% 之间。重复性的相对标准偏差为 1.0% 至 6.3%,实验室内重复性的相对标准偏差为 1.6% 至 7.1%。所有分析物的定量限均为 1.0 µg kg-1。在东京市场上销售的 60 份牛奶样品中,没有一份含有任何分析物。该新型方法性能优越,可用于牛奶中极性抗生素碳青霉烯类的常规监测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
7.40
自引率
6.90%
发文量
136
审稿时长
3 months
期刊介绍: Food Additives & Contaminants: Part A publishes original research papers and critical reviews covering analytical methodology, occurrence, persistence, safety evaluation, detoxification and regulatory control of natural and man-made additives and contaminants in the food and animal feed chain. Papers are published in the areas of food additives including flavourings, pesticide and veterinary drug residues, environmental contaminants, plant toxins, mycotoxins, marine biotoxins, trace elements, migration from food packaging, food process contaminants, adulteration, authenticity and allergenicity of foods. Papers are published on animal feed where residues and contaminants can give rise to food safety concerns. Contributions cover chemistry, biochemistry and bioavailability of these substances, factors affecting levels during production, processing, packaging and storage; the development of novel foods and processes; exposure and risk assessment.
期刊最新文献
Contaminants and residues have varied distributions in large volumes of wheat. Co-occurrence and correlation of arsenic, cadmium, and lead in processed foods intended for infants and young children: evaluation of two statistical approaches adapted to censored data and their implications for risk management. Hazard assessment of fenozan, a released non-intentionally added substance from polyester-based can coating. Preliminary risk assessment of exposure to 3-monochloropropanediol and glycidyl fatty acid esters from infant formula and baby food products on the Saudi market. Trends in acrylamide content in selected potato/sweet potato products on the Canadian market.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1