S. Cabezudo Ballesteros , P. Sanabria Carretero, F. Reinoso Barbero
{"title":"Revisión de la tomografía por impedancia eléctrica en el paciente pediátrico","authors":"S. Cabezudo Ballesteros , P. Sanabria Carretero, F. Reinoso Barbero","doi":"10.1016/j.redar.2023.08.003","DOIUrl":null,"url":null,"abstract":"<div><p>Electrical impedance tomography is a new method of monitoring non-invasive mechanical ventilation, at the bedside and useful in critically ill patients. It allows lung monitoring of ventilation and perfusion, obtaining images that provide information on lung function. It is based on the physical principle of impedanciometry or the body's ability to conduct an electrical current. Various studies have shown its usefulness both in adults and in pediatrics in respiratory distress syndrome, pneumonia and atelectasis in addition to pulmonary thromboembolism and pulmonary hypertension by also providing information on pulmonary perfusion, and may be very useful in perioperative medicine; especially in pediatrics avoiding repetitive imaging tests with ionizing radiation.</p></div>","PeriodicalId":46479,"journal":{"name":"Revista Espanola de Anestesiologia y Reanimacion","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Espanola de Anestesiologia y Reanimacion","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S003493562300289X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Electrical impedance tomography is a new method of monitoring non-invasive mechanical ventilation, at the bedside and useful in critically ill patients. It allows lung monitoring of ventilation and perfusion, obtaining images that provide information on lung function. It is based on the physical principle of impedanciometry or the body's ability to conduct an electrical current. Various studies have shown its usefulness both in adults and in pediatrics in respiratory distress syndrome, pneumonia and atelectasis in addition to pulmonary thromboembolism and pulmonary hypertension by also providing information on pulmonary perfusion, and may be very useful in perioperative medicine; especially in pediatrics avoiding repetitive imaging tests with ionizing radiation.