An in vitro assessment of optimizing implant positions in bilateral distal extension implant-assisted removable partial dentures: A microstress analysis.

IF 1 Q3 DENTISTRY, ORAL SURGERY & MEDICINE The Journal of Indian Prosthodontic Society Pub Date : 2024-01-01 Epub Date: 2024-01-24 DOI:10.4103/jips.jips_388_23
Dipayan Bhattacharya, A A Ponnanna, Ranganatha Rao K Jingade, Subhabrata Maiti, Nitesh Rai, Muralidhar Gopalkrishna
{"title":"An in vitro assessment of optimizing implant positions in bilateral distal extension implant-assisted removable partial dentures: A microstress analysis.","authors":"Dipayan Bhattacharya, A A Ponnanna, Ranganatha Rao K Jingade, Subhabrata Maiti, Nitesh Rai, Muralidhar Gopalkrishna","doi":"10.4103/jips.jips_388_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>The aim of this study was to analyze and compare the stress distribution on dental implants in various positions when used with implant-assisted removable partial dentures.</p><p><strong>Settings and design: </strong>This was an in vitro study.</p><p><strong>Materials and methods: </strong>A model representing a mandibular bilateral partially edentulous condition, with missing premolars and molars, was fabricated using epoxy resin. Two implants of similar diameter measuring 4.0 mm × 10 mm (Dentium, Korea) were inserted in the second molar and the second premolar region on either side of the model for comparing the biomechanical effect of various implant locations. Two types of loads 100N and 125N were applied vertically using universal testing machines in the premolar and molar regions. The loads on the implants beneath the cast partial denture were measured by physical stress analysis using a microstrain gauge.</p><p><strong>Statistical analysis used: </strong>A comparison of maximum stress observed at the premolar versus molar regions due to the application of the 100N and 125N loads was done using the Mann-Whitney U-test.</p><p><strong>Results: </strong>In physical stress analysis, obtained results were statistically analyzed, and the result was statistically not significant (P = 0.435 at 100N and P = 0.718 at 125N) in positional changes of implant.</p><p><strong>Conclusion: </strong>In the current study, the statistical analysis of physical stress revealed no significant differences in stress values between the loadings at the premolar and molar regions. This suggests that the implant can be placed in either the premolar or molar region based on the availability of bone without affecting stress distribution.</p>","PeriodicalId":22669,"journal":{"name":"The Journal of Indian Prosthodontic Society","volume":"24 1","pages":"82-87"},"PeriodicalIF":1.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10896312/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Indian Prosthodontic Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jips.jips_388_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/24 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: The aim of this study was to analyze and compare the stress distribution on dental implants in various positions when used with implant-assisted removable partial dentures.

Settings and design: This was an in vitro study.

Materials and methods: A model representing a mandibular bilateral partially edentulous condition, with missing premolars and molars, was fabricated using epoxy resin. Two implants of similar diameter measuring 4.0 mm × 10 mm (Dentium, Korea) were inserted in the second molar and the second premolar region on either side of the model for comparing the biomechanical effect of various implant locations. Two types of loads 100N and 125N were applied vertically using universal testing machines in the premolar and molar regions. The loads on the implants beneath the cast partial denture were measured by physical stress analysis using a microstrain gauge.

Statistical analysis used: A comparison of maximum stress observed at the premolar versus molar regions due to the application of the 100N and 125N loads was done using the Mann-Whitney U-test.

Results: In physical stress analysis, obtained results were statistically analyzed, and the result was statistically not significant (P = 0.435 at 100N and P = 0.718 at 125N) in positional changes of implant.

Conclusion: In the current study, the statistical analysis of physical stress revealed no significant differences in stress values between the loadings at the premolar and molar regions. This suggests that the implant can be placed in either the premolar or molar region based on the availability of bone without affecting stress distribution.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
体外评估双侧远端延伸种植体辅助活动局部义齿的种植体位置优化:微应力分析
目的:本研究旨在分析和比较与种植体辅助活动局部义齿一起使用时,种植体在不同位置的应力分布:这是一项体外研究:使用环氧树脂制作了一个下颌双侧部分缺牙、前磨牙和臼齿缺失的模型。在模型两侧的第二磨牙和第二前磨牙区域分别植入两个直径为 4.0 毫米 × 10 毫米(Dentium,韩国)的类似种植体,以比较不同种植体位置的生物力学效应。使用万能试验机在前磨牙和臼齿区垂直施加 100N 和 125N 两种载荷。通过使用微应变计进行物理应力分析,测量了铸造局部义齿下种植体的负荷:使用 Mann-Whitney U 检验法比较了前磨牙和磨牙区域在施加 100N 和 125N 负载时观察到的最大应力:在物理应力分析中,对所获得的结果进行了统计分析,结果显示种植体位置变化的统计学意义不显著(100N 时 P = 0.435,125N 时 P = 0.718):在本次研究中,物理应力统计分析显示,前磨牙和臼齿区域的应力值没有明显差异。这表明种植体可以根据牙槽骨的可用性放置在前磨牙或磨牙区域,而不会影响应力分布。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
The Journal of Indian Prosthodontic Society
The Journal of Indian Prosthodontic Society DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.20
自引率
8.30%
发文量
26
审稿时长
20 weeks
期刊最新文献
Comparison of the antibacterial efficacy of 810 nm diode laser and photodynamic therapy in reducing microbial flora in patients with peri-implant mucositis - An in vivo study. Evaluation of marginal accuracy of polyetheretherketone and zirconia copings fabricated using computer-aided design/computer-aided manufacturing technique: An in vitro study. Incorporation of opacifier to Type III alpha gypsum and its effect on scannability and linear setting expansion - An in vitro study. Over-provisionals - Simplified chairside preoperative evaluation of esthetic and functional changes during full mouth rehabilitation. Reporting guidelines: Elevating standards in scientific communication.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1