Is Lateral Onset Cross Pin Technique Strong Enough? A Biomechanical Study.

IF 1 Q3 MEDICINE, GENERAL & INTERNAL Medical Bulletin of Sisli Etfal Hospital Pub Date : 2023-12-29 eCollection Date: 2023-01-01 DOI:10.14744/SEMB.2023.87528
Ahmet Oztermeli, Nazim Karahan, Murat Kaya
{"title":"Is Lateral Onset Cross Pin Technique Strong Enough? A Biomechanical Study.","authors":"Ahmet Oztermeli, Nazim Karahan, Murat Kaya","doi":"10.14744/SEMB.2023.87528","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>It is aimed to compare biomechanically the 3 different pin techniques and the lateral onset cross-pinning (LXP) technique in supracondylar humeral fractures.</p><p><strong>Methods: </strong>Biomechanical testing was performed on 52 synthetic humeriFour pin configurations techniques were tested: crossed pins (XP), 2 lateral pins (2LP), 3 lateral pins (3LP), and LXP technique. Biomechanical testing was performed on Shimadzu Autograph measuring machine. Each pin configuration was tested in a total of 13 humeri: 4 in varus bending, 4 in valgus bending, and 5 in flexion bending. Displacement (mm), and load (N) data were sampled at 10 Hz during each test.</p><p><strong>Results: </strong>Varus values were statistically lower in 2 LP group comparing to XP, 3 LP, LXP groups (p=0.01, p=0.02, p=0.012, consequently). Flexion load values statistically lower in 2 LP group comparing to XP, 3 LP, LXP groups (p=0.03, p=0.001, p=0,031, consequently). There was no difference between the groups in terms of valgus values (p>0.05).</p><p><strong>Conclusion: </strong>LXP technique is biomechanically similar to the traditional XP technique. In situations where orthopedic surgeons choose to use medial pins in addition to lateral pins such as distal humerus fractures with medial-sided defects.</p>","PeriodicalId":42218,"journal":{"name":"Medical Bulletin of Sisli Etfal Hospital","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2023-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10805040/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Bulletin of Sisli Etfal Hospital","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14744/SEMB.2023.87528","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: It is aimed to compare biomechanically the 3 different pin techniques and the lateral onset cross-pinning (LXP) technique in supracondylar humeral fractures.

Methods: Biomechanical testing was performed on 52 synthetic humeriFour pin configurations techniques were tested: crossed pins (XP), 2 lateral pins (2LP), 3 lateral pins (3LP), and LXP technique. Biomechanical testing was performed on Shimadzu Autograph measuring machine. Each pin configuration was tested in a total of 13 humeri: 4 in varus bending, 4 in valgus bending, and 5 in flexion bending. Displacement (mm), and load (N) data were sampled at 10 Hz during each test.

Results: Varus values were statistically lower in 2 LP group comparing to XP, 3 LP, LXP groups (p=0.01, p=0.02, p=0.012, consequently). Flexion load values statistically lower in 2 LP group comparing to XP, 3 LP, LXP groups (p=0.03, p=0.001, p=0,031, consequently). There was no difference between the groups in terms of valgus values (p>0.05).

Conclusion: LXP technique is biomechanically similar to the traditional XP technique. In situations where orthopedic surgeons choose to use medial pins in addition to lateral pins such as distal humerus fractures with medial-sided defects.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
侧向起动十字栓技术是否足够强大?生物力学研究。
目的目的是比较肱骨髁上骨折中 3 种不同销钉技术和侧方起始交叉销钉(LXP)技术的生物力学效果:在 52 个合成肱骨上进行了生物力学测试,测试了四种插针配置技术:交叉插针(XP)、2 侧插针(2LP)、3 侧插针(3LP)和 LXP 技术。生物力学测试在岛津 Autograph 测量机上进行。每种针脚配置共对 13 个肱骨进行了测试:4 个肱骨屈曲,4 个肱骨外翻,5 个肱骨屈曲。每次测试都以 10 Hz 的频率对位移(毫米)和载荷(牛顿)数据进行采样:与 XP 组、3 LP 组和 LXP 组相比,2 LP 组的屈曲值在统计学上较低(P=0.01、P=0.02、P=0.012)。与 XP 组、3 LP 组和 LXP 组相比,2 LP 组的屈曲负荷值在统计学上较低(P=0.03、P=0.001、P=0.031)。各组的外翻值没有差异(P>0.05):结论:LXP 技术在生物力学上与传统 XP 技术相似。结论:LXP 技术在生物力学上与传统 XP 技术相似,在骨科医生选择使用内侧销钉而非外侧销钉的情况下,如肱骨远端骨折伴内侧缺损。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Medical Bulletin of Sisli Etfal Hospital
Medical Bulletin of Sisli Etfal Hospital MEDICINE, GENERAL & INTERNAL-
自引率
16.70%
发文量
41
期刊最新文献
An Analytical Comparison of Papillary Thyroid Carcinoma Patients Manifested with or without Graves' Disease. Can Galanin Be Used as a Marker of Microvascular Dysfunction in Prehypertensives? Can Laryngeal Mask Airway be the First Choice for Tracheal Stenosis Surgery? A Historical Cohort Study. Coexistence of Thyroglossal Cyst and Thyroid Disease in Adults: Surgical Outcomes From A Single Center. Comparative Analysis of Pain and Duration in Panretinal Photocoagulation: Navilas Laser versus Conventional Laser in Proliferative Diabetic Retinopathy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1