{"title":"Seismic performance evaluation of water supply pipes installed in a full-scale RC frame structure based on a shaking table test","authors":"","doi":"10.1007/s11803-024-2232-1","DOIUrl":null,"url":null,"abstract":"<h3>Abstract</h3> <p>As an important part of nonstructural components, the seismic response of indoor water supply pipes deserves much attention. This paper presents shaking table test research on water supply pipes installed in a full-scale reinforced concrete (RC) frame structure. Different material pipes and different methods for penetrating the reinforced concrete floors are combined to evaluate the difference in seismic performance. Floor response spectra and pipe acceleration amplification factors based on test data are discussed and compared with code provisions. A seismic fragility study of displacement demand is conducted based on numerical simulation. The acceleration response and displacement response of different combinations are compared. The results show that the combination of different pipe materials and different passing-through methods can cause obvious differences in the seismic response of indoor riser pipes.</p>","PeriodicalId":11416,"journal":{"name":"Earthquake Engineering and Engineering Vibration","volume":"4 1","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Earthquake Engineering and Engineering Vibration","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s11803-024-2232-1","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0
Abstract
As an important part of nonstructural components, the seismic response of indoor water supply pipes deserves much attention. This paper presents shaking table test research on water supply pipes installed in a full-scale reinforced concrete (RC) frame structure. Different material pipes and different methods for penetrating the reinforced concrete floors are combined to evaluate the difference in seismic performance. Floor response spectra and pipe acceleration amplification factors based on test data are discussed and compared with code provisions. A seismic fragility study of displacement demand is conducted based on numerical simulation. The acceleration response and displacement response of different combinations are compared. The results show that the combination of different pipe materials and different passing-through methods can cause obvious differences in the seismic response of indoor riser pipes.
期刊介绍:
Earthquake Engineering and Engineering Vibration is an international journal sponsored by the Institute of Engineering Mechanics (IEM), China Earthquake Administration in cooperation with the Multidisciplinary Center for Earthquake Engineering Research (MCEER), and State University of New York at Buffalo. It promotes scientific exchange between Chinese and foreign scientists and engineers, to improve the theory and practice of earthquake hazards mitigation, preparedness, and recovery.
The journal focuses on earthquake engineering in all aspects, including seismology, tsunamis, ground motion characteristics, soil and foundation dynamics, wave propagation, probabilistic and deterministic methods of dynamic analysis, behavior of structures, and methods for earthquake resistant design and retrofit of structures that are germane to practicing engineers. It includes seismic code requirements, as well as supplemental energy dissipation, base isolation, and structural control.