{"title":"Real-World Continuous Glucose Monitoring Data from a Population with Type 1 Diabetes in South Korea: Nationwide Single-System Analysis.","authors":"Ji Yoon Kim, Sang-Man Jin, Sarah B Andrade, Boyang Chen, Jae Hyeon Kim","doi":"10.1089/dia.2023.0513","DOIUrl":null,"url":null,"abstract":"<p><p><b><i>Background:</i></b> We used continuous glucose monitoring (CGM) data to investigate glycemic outcomes in a real-world population with type 1 diabetes (T1D) from South Korea, where the widespread use of CGM and the nationwide education program began almost simultaneously. <b><i>Methods:</i></b> Data from Dexcom G6 users with T1D in South Korea were collected between January 2019 and January 2023. Users were included if they provided at least 90 days of glucose data and used CGM at least 70% of the days in the investigational period. The relationship between CGM utilization and glycemic metrics, including the percentage of time in range (TIR), time below range (TBR), and time above range (TAR), was assessed. The study was approved by the Institutional Review Board of Samsung Medical Center (SMC 2023-05-030). <b><i>Results:</i></b> A total of 2288 users were included. Mean age was 41.5 years (57% female), with average uploads of 428 days. Mean TIR was 62.4% ± 18.5%, mean TBR <70 mg/dL was 2.6% ± 2.8%, mean TAR >180 mg/dL was 35.0% ± 19.3%, mean glucose was 168.1 ± 35.8 mg/dL, mean glucose management indicator was 7.2% ± 0.9%, and mean coefficient of variation was 36.7% ± 6.0%. Users with higher CGM utilization had higher TIR (67.8% vs. 52.7%), and lower TBR <70 mg/dL (2.3% vs. 4.7%) and TAR >180 mg/dL (30.0% vs. 42.6%) than those with low CGM utilization (<i>P</i> < 0.001 for all). Users whose data were shared with others had higher TIR than those who did not (63.3% vs. 60.8%, <i>P</i> = 0.001). <b><i>Conclusions:</i></b> In this South Korean population, higher CGM utilization was associated with a favorably higher mean TIR, which was close to the internationally recommended target. Using its remote data-sharing feature showed beneficial impact on TIR.</p>","PeriodicalId":11159,"journal":{"name":"Diabetes technology & therapeutics","volume":null,"pages":null},"PeriodicalIF":5.7000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diabetes technology & therapeutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/dia.2023.0513","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/26 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
引用次数: 0

Abstract

Background: We used continuous glucose monitoring (CGM) data to investigate glycemic outcomes in a real-world population with type 1 diabetes (T1D) from South Korea, where the widespread use of CGM and the nationwide education program began almost simultaneously. Methods: Data from Dexcom G6 users with T1D in South Korea were collected between January 2019 and January 2023. Users were included if they provided at least 90 days of glucose data and used CGM at least 70% of the days in the investigational period. The relationship between CGM utilization and glycemic metrics, including the percentage of time in range (TIR), time below range (TBR), and time above range (TAR), was assessed. The study was approved by the Institutional Review Board of Samsung Medical Center (SMC 2023-05-030). Results: A total of 2288 users were included. Mean age was 41.5 years (57% female), with average uploads of 428 days. Mean TIR was 62.4% ± 18.5%, mean TBR <70 mg/dL was 2.6% ± 2.8%, mean TAR >180 mg/dL was 35.0% ± 19.3%, mean glucose was 168.1 ± 35.8 mg/dL, mean glucose management indicator was 7.2% ± 0.9%, and mean coefficient of variation was 36.7% ± 6.0%. Users with higher CGM utilization had higher TIR (67.8% vs. 52.7%), and lower TBR <70 mg/dL (2.3% vs. 4.7%) and TAR >180 mg/dL (30.0% vs. 42.6%) than those with low CGM utilization (P < 0.001 for all). Users whose data were shared with others had higher TIR than those who did not (63.3% vs. 60.8%, P = 0.001). Conclusions: In this South Korean population, higher CGM utilization was associated with a favorably higher mean TIR, which was close to the internationally recommended target. Using its remote data-sharing feature showed beneficial impact on TIR.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
韩国 1 型糖尿病患者的实际连续血糖监测数据:全国单一系统分析。
背景:我们利用连续血糖监测(CGM)数据调查了韩国 1 型糖尿病(T1D)真实人群的血糖结果:在 2019 年 1 月至 2023 年 1 月期间收集了韩国 Dexcom G6 T1D 用户的数据。如果用户提供了至少 90 天的血糖数据,并且在调查期间至少有 70% 的天数使用了 CGM,则将其纳入调查范围。评估了 CGM 使用率与血糖指标(包括在范围内的时间百分比(TIR)、低于范围的时间百分比(TBR)和高于范围的时间百分比(TAR))之间的关系:结果:共纳入 2,288 名用户。平均年龄为 41.5 岁(57% 为女性),平均上传时间为 428 天。平均 TIR 为 62.4±18.5%,平均 TBR180 mg/dL 为 35.0±19.3%,平均血糖为 168.1±35.8mg/dL,平均血糖管理指标为 7.2±0.9%,平均变异系数为 36.7±6.0%。与 CGM 使用率低的用户相比,CGM 使用率高的用户的 TIR 较高(67.8% 对 52.7%),TBR180 mg/dL 较低(30.0% 对 42.6%):在这一韩国人群中,较高的 CGM 使用率与较高的平均 TIR 值相关,TIR 值接近国际推荐的目标值。使用远程数据共享功能对 TIR 有益。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Diabetes technology & therapeutics
Diabetes technology & therapeutics 医学-内分泌学与代谢
CiteScore
10.60
自引率
14.80%
发文量
145
审稿时长
3-8 weeks
期刊介绍: Diabetes Technology & Therapeutics is the only peer-reviewed journal providing healthcare professionals with information on new devices, drugs, drug delivery systems, and software for managing patients with diabetes. This leading international journal delivers practical information and comprehensive coverage of cutting-edge technologies and therapeutics in the field, and each issue highlights new pharmacological and device developments to optimize patient care.
期刊最新文献
Safety of Options to "Boost" (Enhancing Insulin Infusion Rates) and "Ease-Off" (Reducing Insulin Infusion Rates) in CamAPS FX Hybrid Closed-Loop System: A Real-World Analysis. Clinical Utility of Serum C-peptide Concentration for Hospitalized Patients with Hyperglycemia. An Automated Insulin Delivery System with Automatic Meal Bolus Based on a Hand-Gesturing Algorithm. Noninvasive Real-Time Glucose Monitoring Is in the Near Future. Accuracy of a Real-Time Continuous Glucose Monitor in Pediatric Diabetic Ketoacidosis Admissions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1