Perioperative management of patients with cardiac implantable electronic devices.

IF 4.2 4区 医学 Q1 ANESTHESIOLOGY Korean Journal of Anesthesiology Pub Date : 2024-06-01 Epub Date: 2024-01-29 DOI:10.4097/kja.23826
Minsu Kim, Chang Hee Kwon
{"title":"Perioperative management of patients with cardiac implantable electronic devices.","authors":"Minsu Kim, Chang Hee Kwon","doi":"10.4097/kja.23826","DOIUrl":null,"url":null,"abstract":"<p><p>The use of cardiac implantable electronic devices (CIEDs) has increased significantly in recent years. Consequently, more patients with CIEDs will undergo surgery during their lifetime, and thus the involvement of anesthesiologists in the perioperative management of CIEDs is increasing. With ongoing advancements in technology, many types of CIEDs have been developed, including permanent pacemakers, leadless pacemakers, implantable cardioverter defibrillators, cardiac resynchronization therapy-pacemakers/defibrillators, and implantable loop recorders. The functioning of CIEDs exposed to an electromagnetic field can be affected by electromagnetic interference, potential sources of which can be found in the operating room. Thus, to prevent potential adverse events caused by electromagnetic interference in the operating room, anesthesiologists must have knowledge of CIEDs and be able to identify each type. This review focuses on the perioperative management of patients with CIEDs, including indications for CIED implantation to determine the baseline cardiovascular status of patients; concerns associated with CIEDs before and during surgery; perioperative management of CIEDs, including magnet application and device reprogramming; and additional perioperative provisions for patients with CIEDs. As issues such as variations in programming capabilities and responses to magnet application according to device can be challenging, this review provides essential information for the safe perioperative management of patients with CIEDs.</p>","PeriodicalId":17855,"journal":{"name":"Korean Journal of Anesthesiology","volume":null,"pages":null},"PeriodicalIF":4.2000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11150116/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Anesthesiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4097/kja.23826","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/29 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

The use of cardiac implantable electronic devices (CIEDs) has increased significantly in recent years. Consequently, more patients with CIEDs will undergo surgery during their lifetime, and thus the involvement of anesthesiologists in the perioperative management of CIEDs is increasing. With ongoing advancements in technology, many types of CIEDs have been developed, including permanent pacemakers, leadless pacemakers, implantable cardioverter defibrillators, cardiac resynchronization therapy-pacemakers/defibrillators, and implantable loop recorders. The functioning of CIEDs exposed to an electromagnetic field can be affected by electromagnetic interference, potential sources of which can be found in the operating room. Thus, to prevent potential adverse events caused by electromagnetic interference in the operating room, anesthesiologists must have knowledge of CIEDs and be able to identify each type. This review focuses on the perioperative management of patients with CIEDs, including indications for CIED implantation to determine the baseline cardiovascular status of patients; concerns associated with CIEDs before and during surgery; perioperative management of CIEDs, including magnet application and device reprogramming; and additional perioperative provisions for patients with CIEDs. As issues such as variations in programming capabilities and responses to magnet application according to device can be challenging, this review provides essential information for the safe perioperative management of patients with CIEDs.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
心脏植入式电子设备患者的围手术期管理。
近年来,心脏植入式电子设备(CIED)的使用率大幅上升。因此,越来越多的 CIED 患者将在有生之年接受手术治疗,麻醉医生在 CIED 围手术期管理中的参与度也在不断提高。随着技术的不断进步,已开发出多种类型的 CIED,包括永久起搏器、无引线起搏器、植入式心脏除颤器、心脏再同步治疗起搏器/除颤器和植入式循环记录器。暴露在电磁场中的植入式心律转复除颤器的功能可能会受到电磁干扰的影响,而手术室中就有潜在的电磁干扰源。因此,为防止手术室内电磁干扰造成的潜在不良事件,麻醉医师必须了解 CIED 的相关知识,并能够识别每种类型的 CIED。本综述重点关注CIED患者的围术期管理,包括CIED植入的适应症,以确定患者的心血管基线状态;术前和术中与CIED相关的问题;CIED的围术期管理,包括磁铁应用和设备重新编程;以及CIED患者围术期的其他规定。由于不同设备的编程能力和对磁铁应用的反应等问题可能具有挑战性,本综述为 CIED 患者的安全围术期管理提供了重要信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
6.20
自引率
6.90%
发文量
84
审稿时长
16 weeks
期刊最新文献
Comprehensive guidelines for appropriate statistical analysis methods in research. Effects of opioid-sparing general anesthesia on postoperative nausea and vomiting in laparoscopic gynecological surgery. Reverse tube direction and epistaxis in left nasotracheal intubation: a randomized controlled trial. Ramped versus sniffing position for Ambu® AuraGain™ insertion in patients with obesity: a randomized controlled study. Comment on "The incidences of nausea and vomiting after general anesthesia with remimazolam versus sevoflurane: a prospective randomized controlled trial".
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1