Laser-tracker-based reference measurement for geometric calibration of phase-measuring deflectometry with active display registration

Pub Date : 2024-01-26 DOI:10.5194/jsss-13-1-2024
Yann Sperling, Ralf Bernhard Bergmann
{"title":"Laser-tracker-based reference measurement for geometric calibration of phase-measuring deflectometry with active display registration","authors":"Yann Sperling, Ralf Bernhard Bergmann","doi":"10.5194/jsss-13-1-2024","DOIUrl":null,"url":null,"abstract":"Abstract. Phase-measuring deflectometry (PMD) with active display registration (ADR) is a ray-optics-based technique for the shape measurement of specular surfaces. To obtain quantitative results, the relative position of the cameras of the PMD–ADR setup needs to be determined by geometric calibration. Geometric calibration can be performed by inserting a planar mirror into the setup that brings all camera fields of view to overlap on an active pattern display. The mirror is tilted to multiple positions and each time the cameras capture the displayed images, which yields sufficient data to obtain the relative camera positions and the positions of the mirror. In this article, we give a more detailed description of PMD–ADR and its calibration. We also implement a laser-tracker-based reference method to measure the mirror positions and use its result to expose systematic errors in the geometric calibration.\n","PeriodicalId":0,"journal":{"name":"","volume":"43 41","pages":""},"PeriodicalIF":0.0,"publicationDate":"2024-01-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5194/jsss-13-1-2024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract. Phase-measuring deflectometry (PMD) with active display registration (ADR) is a ray-optics-based technique for the shape measurement of specular surfaces. To obtain quantitative results, the relative position of the cameras of the PMD–ADR setup needs to be determined by geometric calibration. Geometric calibration can be performed by inserting a planar mirror into the setup that brings all camera fields of view to overlap on an active pattern display. The mirror is tilted to multiple positions and each time the cameras capture the displayed images, which yields sufficient data to obtain the relative camera positions and the positions of the mirror. In this article, we give a more detailed description of PMD–ADR and its calibration. We also implement a laser-tracker-based reference method to measure the mirror positions and use its result to expose systematic errors in the geometric calibration.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
基于激光跟踪器的参考测量,用于对带有主动显示注册功能的相位测量偏转仪进行几何校准
摘要带主动显示注册(ADR)的相位测量偏转仪(PMD)是一种基于射线光学的镜面形状测量技术。要获得定量结果,需要通过几何校准来确定 PMD-ADR 设置的摄像头的相对位置。几何校准可通过在装置中插入一个平面镜来实现,该平面镜可使所有相机的视场在活动图案显示屏上重叠。将平面镜倾斜到多个位置,每次摄像机都会捕捉到显示的图像,从而获得足够的数据来确定摄像机的相对位置和平面镜的位置。在本文中,我们将更详细地介绍 PMD-ADR 及其校准。我们还采用了一种基于激光跟踪器的参考方法来测量镜面位置,并利用其结果来揭示几何校准中的系统误差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1