A.P. Swafford , B. Lim , K.E. Conroy , J.A. Mercer
{"title":"Core temperature while swimming in warm water wearing a triathlon wetsuit","authors":"A.P. Swafford , B. Lim , K.E. Conroy , J.A. Mercer","doi":"10.1016/j.scispo.2023.03.009","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>The purpose was to determine if core temperature was influenced by wearing a triathlon wetsuit while swimming in warm water (25.5<!--> <!-->°C).</p></div><div><h3>Summary of facts and results</h3><p>Participants (<em>n</em> <!-->=<!--> <!-->5) completed two 1000<!--> <!-->m swim conditions: wearing a full sleeve wetsuit (W<sub>Full</sub>) and no wetsuit (NWS) at a self-selected pace. Condition order was randomized. Core temperature was measured using an ingestible telemetry core temperature pill. Initial temperature (T<sub>i</sub>), final temperature (T<sub>f</sub>), average temperature (T<sub>AVG</sub>) and rate of change of temperature (ΔT/Δt) were recorded for analysis. Core temperature was analyzed using a 2 (condition: W<sub>Full</sub>, NWS)<!--> <!-->×<!--> <!-->2 (time: Ti, Tf) repeated measures analysis of variance. Stroke rate, performance time, T<sub>AVG</sub>, and ΔT/Δt were compared between conditions using paired <em>t</em>-tests. Core temperature was not influenced by the interaction of condition and time (<em>P</em> <!-->=<!--> <!-->0.118) nor by condition (<em>P</em> <!-->=<!--> <!-->0.695) but was influenced by time (<em>P</em> <!-->=<!--> <!-->0.012). T<sub>AVG</sub>, ΔT/Δt, and stroke rate were not different between conditions (<em>P</em> <!-->><!--> <!-->0.05). Swim performance was faster for the W<sub>Full</sub> (861.9<!--> <!-->±<!--> <!-->109.0<!--> <!-->s) vs. NWS condition (912.1<!--> <!-->±<!--> <!-->114.7<!--> <!-->s; <em>P</em> <!--><<!--> <!-->0.05).</p></div><div><h3>Conclusion</h3><p>Core temperature during swimming in warm water (25.5<!--> <!-->°C) at self-selected pace was not influenced by wearing a wetsuit.</p></div><div><h3>Introduction</h3><p>L’objectif de cette étude était de déterminer si la température corporelle était influencée par le port d’une combinaison de triathlon lors de la natation en eau chaude (25,5<!--> <!-->°C).</p></div><div><h3>Résumé des faits et résultats</h3><p>Les participants (<em>n</em> <!-->=<!--> <!-->5) ont nagé sur une distance de 1000<!--> <!-->m dans deux conditions : en portant une combinaison à manches complètes (WFull) ou sans combinaison (NWS), à une vitesse de libre choix. L’ordre des conditions était aléatoire. La température centrale a été mesurée à l’aide d’une pilule télémétrique ingérable. La température initiale (Ti), la température finale (Tf), la température moyenne (TAVG) et le changement de température (ΔT/Δt) ont été enregistrés pour être analysés. La température centrale a été analysée à l’aide d’une Anova à mesures répétées à 2 voies prenant en compte les effets de la condition (WFull versus NWS) et du temps de mesure (Ti versus Tf). La fréquence cardiaque, les performances, les TAVG et ΔT/Δt ont été comparés entre les différentes conditions à l’aide de tests <em>t</em> appariés. La température centrale n’a pas été influencée par l’interaction entre la condition et le temps (<em>p</em> <!-->=<!--> <!-->0,118) ni par la condition (<em>p</em> <!-->=<!--> <!-->0,695), mais a été influencée par le temps (<em>p</em> <!-->=<!--> <!-->0,012). Le TAVG, le ΔT/Δt, et la vitesse de nage n’étaient pas différents entre les conditions (<em>p</em> <!-->><!--> <!-->0,05). La performance de nage était meilleure pour la condition WFull (861,9<!--> <!-->±<!--> <!-->109,0<!--> <!-->s) par comparaison avec la condition NWS (912,1<!--> <!-->±<!--> <!-->114,7<!--> <!-->s ; <em>p</em> <!--><<!--> <!-->0,05).</p></div><div><h3>Conclusion</h3><p>La température centrale pendant la natation en eau chaude (25,5<!--> <!-->°C) à un rythme choisi par l’individu n’a pas été influencée par le port d’une combinaison de triathlon.</p></div>","PeriodicalId":21728,"journal":{"name":"Science & Sports","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Science & Sports","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0765159723002678","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SPORT SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction
The purpose was to determine if core temperature was influenced by wearing a triathlon wetsuit while swimming in warm water (25.5 °C).
Summary of facts and results
Participants (n = 5) completed two 1000 m swim conditions: wearing a full sleeve wetsuit (WFull) and no wetsuit (NWS) at a self-selected pace. Condition order was randomized. Core temperature was measured using an ingestible telemetry core temperature pill. Initial temperature (Ti), final temperature (Tf), average temperature (TAVG) and rate of change of temperature (ΔT/Δt) were recorded for analysis. Core temperature was analyzed using a 2 (condition: WFull, NWS) × 2 (time: Ti, Tf) repeated measures analysis of variance. Stroke rate, performance time, TAVG, and ΔT/Δt were compared between conditions using paired t-tests. Core temperature was not influenced by the interaction of condition and time (P = 0.118) nor by condition (P = 0.695) but was influenced by time (P = 0.012). TAVG, ΔT/Δt, and stroke rate were not different between conditions (P > 0.05). Swim performance was faster for the WFull (861.9 ± 109.0 s) vs. NWS condition (912.1 ± 114.7 s; P < 0.05).
Conclusion
Core temperature during swimming in warm water (25.5 °C) at self-selected pace was not influenced by wearing a wetsuit.
Introduction
L’objectif de cette étude était de déterminer si la température corporelle était influencée par le port d’une combinaison de triathlon lors de la natation en eau chaude (25,5 °C).
Résumé des faits et résultats
Les participants (n = 5) ont nagé sur une distance de 1000 m dans deux conditions : en portant une combinaison à manches complètes (WFull) ou sans combinaison (NWS), à une vitesse de libre choix. L’ordre des conditions était aléatoire. La température centrale a été mesurée à l’aide d’une pilule télémétrique ingérable. La température initiale (Ti), la température finale (Tf), la température moyenne (TAVG) et le changement de température (ΔT/Δt) ont été enregistrés pour être analysés. La température centrale a été analysée à l’aide d’une Anova à mesures répétées à 2 voies prenant en compte les effets de la condition (WFull versus NWS) et du temps de mesure (Ti versus Tf). La fréquence cardiaque, les performances, les TAVG et ΔT/Δt ont été comparés entre les différentes conditions à l’aide de tests t appariés. La température centrale n’a pas été influencée par l’interaction entre la condition et le temps (p = 0,118) ni par la condition (p = 0,695), mais a été influencée par le temps (p = 0,012). Le TAVG, le ΔT/Δt, et la vitesse de nage n’étaient pas différents entre les conditions (p > 0,05). La performance de nage était meilleure pour la condition WFull (861,9 ± 109,0 s) par comparaison avec la condition NWS (912,1 ± 114,7 s ; p < 0,05).
Conclusion
La température centrale pendant la natation en eau chaude (25,5 °C) à un rythme choisi par l’individu n’a pas été influencée par le port d’une combinaison de triathlon.
期刊介绍:
Science & Sports is a peer-reviewed journal, publishing worldwide high-quality and impactful papers of medical, scientific and applied technical research in the different fields of sports and physical activities: sport medicine, exercise physiology, sport physiology and performance, nutrition, traumatology relating to sport, rehabilitation or adapted physical activities. It facilitates the transfer of knowledge and technology between the clinic, research and practice in physical and athletic activity.