{"title":"Validation of the 35-mm rule in traumatic pneumothorax in an Asian population.","authors":"Woo Young Nho","doi":"10.1080/00325481.2024.2313449","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Thoracic injury crucially threatens human health. Recent studies have suggested using computed tomography (CT) to observe traumatic pneumothorax (PTX). However, cross-ethnic validation is required to overcome potential barriers for the global application of this method. This study aimed to validate the 35-mm rule in traumatic PTX in a Korean population.</p><p><strong>Methods: </strong>Data from the institutional registry were analyzed, and chest CT images were reviewed. Factors for observation failure were evaluated via logistic regression analysis, and a receiver-operating curve was created to calculate the optimal cutoff value.</p><p><strong>Results: </strong>In total, 286 participants were included in this study. The average PTX size was 8.2 (3.2-26.5) mm, and 210 of 213 (95.3%) initially observed patients with a PTX size of ≤35 mm successfully completed the safety observation. Multivariate regression analysis revealed that a PTX size of >35 mm is associated with observation failure and suggested a cutoff of 24.5 mm.</p><p><strong>Conclusion: </strong>Most patients with traumatic PTX of ≤35 mm on CT had undergone successful 4-h observation without thoracostomy. Additionally, PTX of >35 mm was an independent risk factor for observation failure. Considering the lower optimal cutoff value and high failure rates observed in this study, the current guidelines need modifications.</p>","PeriodicalId":94176,"journal":{"name":"Postgraduate medicine","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Postgraduate medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/00325481.2024.2313449","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/6 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: Thoracic injury crucially threatens human health. Recent studies have suggested using computed tomography (CT) to observe traumatic pneumothorax (PTX). However, cross-ethnic validation is required to overcome potential barriers for the global application of this method. This study aimed to validate the 35-mm rule in traumatic PTX in a Korean population.
Methods: Data from the institutional registry were analyzed, and chest CT images were reviewed. Factors for observation failure were evaluated via logistic regression analysis, and a receiver-operating curve was created to calculate the optimal cutoff value.
Results: In total, 286 participants were included in this study. The average PTX size was 8.2 (3.2-26.5) mm, and 210 of 213 (95.3%) initially observed patients with a PTX size of ≤35 mm successfully completed the safety observation. Multivariate regression analysis revealed that a PTX size of >35 mm is associated with observation failure and suggested a cutoff of 24.5 mm.
Conclusion: Most patients with traumatic PTX of ≤35 mm on CT had undergone successful 4-h observation without thoracostomy. Additionally, PTX of >35 mm was an independent risk factor for observation failure. Considering the lower optimal cutoff value and high failure rates observed in this study, the current guidelines need modifications.