Impact of stroke volume assessment by three-dimensional transesophageal echocardiography on the classification of low-gradient aortic stenosis.

IF 1.4 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Journal of Echocardiography Pub Date : 2024-09-01 Epub Date: 2024-02-01 DOI:10.1007/s12574-023-00638-4
Nobuichiro Yagi, Mana Ogawa, Ken Kuwajima, Hiroko Hasegawa, Takafumi Yamane, Takahiro Shiota
{"title":"Impact of stroke volume assessment by three-dimensional transesophageal echocardiography on the classification of low-gradient aortic stenosis.","authors":"Nobuichiro Yagi, Mana Ogawa, Ken Kuwajima, Hiroko Hasegawa, Takafumi Yamane, Takahiro Shiota","doi":"10.1007/s12574-023-00638-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Accurate assessment of flow status is crucial in low-gradient aortic stenosis (AS). However, the clinical implication of three-dimensional transesophageal echocardiography (3DTEE) on flow status evaluation remains unclear. This study aimed to investigate the assessment of flow status using 3D TEE in low-gradient AS patients.</p><p><strong>Methods: </strong>We retrospectively reviewed patients diagnosed with low-gradient AS and preserved ejection fraction at our institution between 2019 and 2022. Patients were categorized into low-flow/low-gradient (LF-LG) AS or normal-flow/low-gradient (NF-LG) AS based on two-dimensional transthoracic echocardiography (2DTTE). We compared the left ventricular outflow tract (LVOT) geometry between the two groups and reclassified them using stroke volume index (SVi) obtained by 3DTEE.</p><p><strong>Results: </strong>Among 173 patients (105 with LF-LG AS and 68 with NF-LG AS), 54 propensity-matched pairs of patients were analyzed. 3DTEE-derived ellipticity index of LVOT was significantly higher in LF-LG AS patients compared to NF-LG AS patients (p = 0.012). We assessed the discordance in flow status classification between SVi<sub>2DTTE</sub> and SVi<sub>3DTEE</sub> in both groups using a cutoff value of 35 ml/m<sup>2</sup>. The LF-LG AS group exhibited a significantly higher discordance rate compared to the NF-LG AS group, with rates of 50% and 2%, respectively. The optimal cutoff values of SVi<sub>3DTEE</sub> for identifying low flow status, based on 2DTTE-derived cutoff values, were determined to be 43 ml/m<sup>2</sup>.</p><p><strong>Conclusions: </strong>LVOT ellipticity in low-gradient AS patients varies depending on flow status, and this difference contributes to discrepancies between SVi<sub>3DTEE</sub> and SVi<sub>2DTTE</sub>, particularly in LF-LG AS patients. Utilizing SVi<sub>3DTEE</sub> is valuable for accurately assessing flow status.</p>","PeriodicalId":44837,"journal":{"name":"Journal of Echocardiography","volume":" ","pages":"152-161"},"PeriodicalIF":1.4000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Echocardiography","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12574-023-00638-4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/1 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Accurate assessment of flow status is crucial in low-gradient aortic stenosis (AS). However, the clinical implication of three-dimensional transesophageal echocardiography (3DTEE) on flow status evaluation remains unclear. This study aimed to investigate the assessment of flow status using 3D TEE in low-gradient AS patients.

Methods: We retrospectively reviewed patients diagnosed with low-gradient AS and preserved ejection fraction at our institution between 2019 and 2022. Patients were categorized into low-flow/low-gradient (LF-LG) AS or normal-flow/low-gradient (NF-LG) AS based on two-dimensional transthoracic echocardiography (2DTTE). We compared the left ventricular outflow tract (LVOT) geometry between the two groups and reclassified them using stroke volume index (SVi) obtained by 3DTEE.

Results: Among 173 patients (105 with LF-LG AS and 68 with NF-LG AS), 54 propensity-matched pairs of patients were analyzed. 3DTEE-derived ellipticity index of LVOT was significantly higher in LF-LG AS patients compared to NF-LG AS patients (p = 0.012). We assessed the discordance in flow status classification between SVi2DTTE and SVi3DTEE in both groups using a cutoff value of 35 ml/m2. The LF-LG AS group exhibited a significantly higher discordance rate compared to the NF-LG AS group, with rates of 50% and 2%, respectively. The optimal cutoff values of SVi3DTEE for identifying low flow status, based on 2DTTE-derived cutoff values, were determined to be 43 ml/m2.

Conclusions: LVOT ellipticity in low-gradient AS patients varies depending on flow status, and this difference contributes to discrepancies between SVi3DTEE and SVi2DTTE, particularly in LF-LG AS patients. Utilizing SVi3DTEE is valuable for accurately assessing flow status.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
通过三维经食道超声心动图评估搏出量对低梯度主动脉瓣狭窄分类的影响。
背景:准确评估血流状态对低梯度主动脉瓣狭窄(AS)至关重要。然而,三维经食道超声心动图(3DTEE)对血流状态评估的临床意义仍不明确。本研究旨在探讨使用三维经食道超声心动图评估低梯度主动脉瓣狭窄患者的血流状态:我们回顾性分析了2019年至2022年间在本院确诊为低梯度AS且射血分数保留的患者。根据二维经胸超声心动图(2DTTE)将患者分为低流量/低梯度(LF-LG)AS 或正常流量/低梯度(NF-LG)AS。我们比较了两组患者左心室流出道(LVOT)的几何形状,并使用三维经胸超声心动图获得的搏出量指数(SVi)对两组患者进行了重新分类:在 173 名患者(105 名 LF-LG AS 患者和 68 名 NF-LG AS 患者)中,对 54 对倾向匹配的患者进行了分析。与 NF-LG AS 患者相比,LF-LG AS 患者 LVOT 的 3DTEE 导出椭圆度指数明显更高(p = 0.012)。我们以 35 ml/m2 为临界值,评估了两组 SVi2DTTE 和 SVi3DTEE 在血流状态分类上的不一致性。与 NF-LG AS 组相比,LF-LG AS 组的不一致率明显更高,分别为 50%和 2%。根据 2DTTE 得出的截断值,确定 SVi3DTEE 识别低血流状态的最佳截断值为 43 ml/m2:结论:低梯度强直性脊柱炎患者的左心室出口椭圆度因血流状态而异,这种差异导致了 SVi3DTEE 和 SVi2DTTE 之间的差异,尤其是在低频-低梯度强直性脊柱炎患者中。利用 SVi3DTEE 对准确评估血流状态很有价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Echocardiography
Journal of Echocardiography CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
3.00
自引率
6.20%
发文量
35
期刊介绍: The Journal of Echocardiography, the official journal of the Japanese Society of Echocardiography, publishes work that contributes to progress in the field and articles in clinical research as well, seeking to develop a new focus and new perspectives for all who are concerned with this discipline. The journal welcomes original investigations, review articles, letters to the editor, editorials, and case image in cardiovascular ultrasound, which will be reviewed by the editorial board. The Journal of Echocardiography provides the best of up-to-date information from around the world, presenting readers with high-impact, original work focusing on pivotal issues.
期刊最新文献
Synchronized motion of intracardiac thrombus with preserved left ventricular contraction in a patient with eosinophilic granulomatosis with polyangiitis. Giant progressive mitral vegetation in a case of infective endocarditis caused by Streptococcus agalactiae. Contrast echocardiography during exercise stress in a case of congenitally corrected transposition of the great arteries after double-switch operation. A case of left ventricular outflow tract obstruction detected after transcatheter aortic valve implantation. Extreme shortening of non-coronary cusp of the aortic valve detected by transesophageal echocardiography: a case report.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1