Maria Terricabras, Raphael P Martins, Rafael Peinado, Paweł Derejko, Lluís Mont, Sabine Ernst, David Herranz, Christophe Bailleul, Atul Verma
{"title":"Cardiac Pulsed Field Ablation Lesion Durability Assessed by Polarization-Sensitive Optical Coherence Reflectometry.","authors":"Maria Terricabras, Raphael P Martins, Rafael Peinado, Paweł Derejko, Lluís Mont, Sabine Ernst, David Herranz, Christophe Bailleul, Atul Verma","doi":"10.1161/CIRCEP.123.012255","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Pulsed field ablation uses electrical fields to cause nonthermal cell death over several hours. Polarization-sensitive optical coherence reflectometry is an optical imaging technique that can detect changes in the tissue ultrastructure in real time, which occurs when muscular tissue is damaged. The objective of this study was to evaluate the ability of a polarization-sensitive optical coherence reflectometry system to predict the development of chronic lesions based on acute changes in tissue birefringence during pulsed field ablation.</p><p><strong>Methods: </strong>Superior vena cava isolation was performed in 30 swine using a biphasic, bipolar pulsed field ablation system delivered with a nonirrigated focal tip catheter. Acute changes in tissue birefringence and voltage abatement were analyzed for each individual lesion. A high-resolution electroanatomical map was performed at baseline and 4 to 12 weeks after ablation to locate electrical gaps in the ablated area.</p><p><strong>Results: </strong>A total of 141 lesions were delivered and included in the analysis. Acute electrical isolation based on the electroanatomical map was achieved in 96% of the animals, but chronic isolation was only seen in 14 animals (46%). The mean voltage abatement of lesions that showed recovery was 82.8%±14.6% versus 84.4%±17.4% for those that showed fibrosis (<i>P</i>=0.7). The mean acute reduction in tissue birefringence in points demonstrating fibrosis was 63.8%±11.3% versus 9.1%±0.1% in the points that resulted in electrical gaps. A threshold of acute reduction of birefringence of ≥20% could predict chronic lesion formation with a sensitivity of 96% and a specificity of 83%.</p><p><strong>Conclusions: </strong>Acute tissue birefringence changes assessed with polarization-sensitive optical coherence reflectometry during pulsed field ablation can predict chronic lesion formation and guide the ablation procedure although limited by the tissue thickness.</p>","PeriodicalId":10319,"journal":{"name":"Circulation. Arrhythmia and electrophysiology","volume":" ","pages":"e012255"},"PeriodicalIF":9.1000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10949975/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Circulation. Arrhythmia and electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1161/CIRCEP.123.012255","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/6 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Pulsed field ablation uses electrical fields to cause nonthermal cell death over several hours. Polarization-sensitive optical coherence reflectometry is an optical imaging technique that can detect changes in the tissue ultrastructure in real time, which occurs when muscular tissue is damaged. The objective of this study was to evaluate the ability of a polarization-sensitive optical coherence reflectometry system to predict the development of chronic lesions based on acute changes in tissue birefringence during pulsed field ablation.
Methods: Superior vena cava isolation was performed in 30 swine using a biphasic, bipolar pulsed field ablation system delivered with a nonirrigated focal tip catheter. Acute changes in tissue birefringence and voltage abatement were analyzed for each individual lesion. A high-resolution electroanatomical map was performed at baseline and 4 to 12 weeks after ablation to locate electrical gaps in the ablated area.
Results: A total of 141 lesions were delivered and included in the analysis. Acute electrical isolation based on the electroanatomical map was achieved in 96% of the animals, but chronic isolation was only seen in 14 animals (46%). The mean voltage abatement of lesions that showed recovery was 82.8%±14.6% versus 84.4%±17.4% for those that showed fibrosis (P=0.7). The mean acute reduction in tissue birefringence in points demonstrating fibrosis was 63.8%±11.3% versus 9.1%±0.1% in the points that resulted in electrical gaps. A threshold of acute reduction of birefringence of ≥20% could predict chronic lesion formation with a sensitivity of 96% and a specificity of 83%.
Conclusions: Acute tissue birefringence changes assessed with polarization-sensitive optical coherence reflectometry during pulsed field ablation can predict chronic lesion formation and guide the ablation procedure although limited by the tissue thickness.
期刊介绍:
Circulation: Arrhythmia and Electrophysiology is a journal dedicated to the study and application of clinical cardiac electrophysiology. It covers a wide range of topics including the diagnosis and treatment of cardiac arrhythmias, as well as research in this field. The journal accepts various types of studies, including observational research, clinical trials, epidemiological studies, and advancements in translational research.