Volume change after maxillary sinus floor elevation with apatite carbonate and octacalcium phosphate.

IF 3.1 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE International Journal of Implant Dentistry Pub Date : 2024-02-08 DOI:10.1186/s40729-023-00518-7
Koudai Nagata, Masanobu Kamata, Yurie Okuhama, Kana Wakamori, Manabu Okubo, Hayoto Tsuruoka, Mihoko Atsumi, Hiromasa Kawana
{"title":"Volume change after maxillary sinus floor elevation with apatite carbonate and octacalcium phosphate.","authors":"Koudai Nagata, Masanobu Kamata, Yurie Okuhama, Kana Wakamori, Manabu Okubo, Hayoto Tsuruoka, Mihoko Atsumi, Hiromasa Kawana","doi":"10.1186/s40729-023-00518-7","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Maxillary molars have low alveolar bone height diameter due to the presence of the maxillary sinus; thus, a sinus lift may be required in some cases. Changes in the volume of bone substitutes can affect the success of implant therapy. Therefore, this study aimed to compare the changes in the volume of two different bone substitutes-one based on carbonate apatite and the other on octacalcium phosphate-used in maxillary sinus floor elevation.</p><p><strong>Methods: </strong>Nineteen patients and 20 sites requiring maxillary sinus floor elevation were included in the study. Digital Imaging and Communications in Medicine data for each patient obtained preoperatively and immediately and 6 months postoperatively were used to measure the volume of the bone grafting material using a three-dimensional image analysis software. The immediate postoperative volume of octacalcium phosphate was 95.3775 mm<sup>3</sup> per piece of grafting material used. It was multiplied by the number of pieces used and converted to mL to determine the immediate postoperative volume.</p><p><strong>Results: </strong>The mean resorption values of carbonate apatite and octacalcium phosphate were 12.7 ± 3.6% and 17.3 ± 3.9%, respectively. A significant difference in the amount of resorption of the two bone replacement materials was observed (P = 0.04).</p><p><strong>Conclusions: </strong>The results of this study indicate that both bone substitute materials tend to resorb. The two bone grafting materials that are currently medically approved in Japan have not been in the market for a long time, and their long-term prognosis has not yet been reported. Further clinical data are warranted.</p>","PeriodicalId":14076,"journal":{"name":"International Journal of Implant Dentistry","volume":"10 1","pages":"7"},"PeriodicalIF":3.1000,"publicationDate":"2024-02-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10853090/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Implant Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40729-023-00518-7","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Maxillary molars have low alveolar bone height diameter due to the presence of the maxillary sinus; thus, a sinus lift may be required in some cases. Changes in the volume of bone substitutes can affect the success of implant therapy. Therefore, this study aimed to compare the changes in the volume of two different bone substitutes-one based on carbonate apatite and the other on octacalcium phosphate-used in maxillary sinus floor elevation.

Methods: Nineteen patients and 20 sites requiring maxillary sinus floor elevation were included in the study. Digital Imaging and Communications in Medicine data for each patient obtained preoperatively and immediately and 6 months postoperatively were used to measure the volume of the bone grafting material using a three-dimensional image analysis software. The immediate postoperative volume of octacalcium phosphate was 95.3775 mm3 per piece of grafting material used. It was multiplied by the number of pieces used and converted to mL to determine the immediate postoperative volume.

Results: The mean resorption values of carbonate apatite and octacalcium phosphate were 12.7 ± 3.6% and 17.3 ± 3.9%, respectively. A significant difference in the amount of resorption of the two bone replacement materials was observed (P = 0.04).

Conclusions: The results of this study indicate that both bone substitute materials tend to resorb. The two bone grafting materials that are currently medically approved in Japan have not been in the market for a long time, and their long-term prognosis has not yet been reported. Further clinical data are warranted.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用碳酸磷灰石和磷酸八钙抬高上颌窦底后的体积变化。
目的:由于上颌窦的存在,上颌磨牙的牙槽骨高度直径较低;因此,在某些情况下可能需要进行上颌窦提升术。骨替代物体积的变化会影响种植治疗的成功率。因此,本研究旨在比较上颌窦底提升术中使用的两种不同骨替代物--一种基于碳酸盐磷灰石,另一种基于磷酸八钙--的体积变化:研究共包括 19 名患者和 20 个需要上颌窦底抬高的部位。使用三维图像分析软件测量每位患者术前、术中和术后 6 个月的数字成像和医学通信数据,以测量植骨材料的体积。术后即刻的磷酸八钙体积为每块植骨材料 95.3775 立方毫米。将其乘以所使用的片数,再换算成毫升,就得出了术后即刻体积:碳酸盐磷灰石和磷酸八钙的平均吸收值分别为 12.7 ± 3.6% 和 17.3 ± 3.9%。两种骨替代材料的吸收量存在明显差异(P = 0.04):本研究结果表明,两种骨替代材料都有吸收的倾向。结论:本研究结果表明,这两种骨替代材料都有吸收倾向。目前在日本获得医学批准的两种骨移植材料上市时间不长,其长期预后尚未见报道。需要进一步的临床数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Implant Dentistry
International Journal of Implant Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.70
自引率
7.40%
发文量
53
审稿时长
13 weeks
期刊介绍: The International Journal of Implant Dentistry is a peer-reviewed open access journal published under the SpringerOpen brand. The journal is dedicated to promoting the exchange and discussion of all research areas relevant to implant dentistry in the form of systematic literature or invited reviews, prospective and retrospective clinical studies, clinical case reports, basic laboratory and animal research, and articles on material research and engineering.
期刊最新文献
Electroplated double-crowns on implants and teeth after up to 12 years- a retrospective clinical study. The impact of a 1 mm interimplant distance on the interproximal crestal bone height: a case report with a 10-year follow-up and literature review. Usefulness of a novel density measurement drill for evaluating cancellous bone density: correlation between CT value and drilling torque value in bovine ribs. Treatment of peri-implant mucositis using an Er:YAG laser or an ultrasonic device: a randomized, controlled clinical trial. Prediction models for the complication incidence and survival rate of dental implants-a systematic review and critical appraisal.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1