Utility of tele-guidance for point-of-care ultrasound: a single center prospective diagnostic study.

IF 1.3 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Journal of Ultrasound Pub Date : 2024-09-01 Epub Date: 2024-02-10 DOI:10.1007/s40477-023-00860-x
Eric M Cal, Elias Gunnell, Kristen Olinger, Thad Benefield, Jacob Nelson, Elise Maggioncalda, Katrina McGinty
{"title":"Utility of tele-guidance for point-of-care ultrasound: a single center prospective diagnostic study.","authors":"Eric M Cal, Elias Gunnell, Kristen Olinger, Thad Benefield, Jacob Nelson, Elise Maggioncalda, Katrina McGinty","doi":"10.1007/s40477-023-00860-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Point-of-care-ultrasound (POCUS) improves diagnostic accuracy and expedites lifesaving procedures. Remote areas disproportionately underuse ultrasound (US) due to a dearth of US trained professionals, imaging tools, and lack of quality assurance. Handheld US probes have been approved for diagnostic imaging but there have been limited studies examining their tele-guidance features. This study investigates whether physician tele-guidance improved ultrasound image acquisition by untrained scanners.</p><p><strong>Methods: </strong>To determine the effectiveness of tele-guidance for ultrasound image acquisition, 30 participants (15 in each study arm: experimental and control) with no ultrasound or medical experience gathered images of the heart, right kidney, and gallbladder of a standardized patient using a handheld ultrasound probe (Butterfly iQ +). All participants watched a standardized ultrasound tutorial video and were randomized into the control or experimental group. A physician assisted the experimental group using ultrasound probe's tele-guidance feature while the control group received no assistance. Time to image acquisition was recorded for both groups, and the images were graded by 3 blinded radiologists using the RACE tool to determine image and diagnostic quality.</p><p><strong>Results: </strong>There was evidence that mean imaging time was greater in the control group for the heart, right kidney, and gallbladder (p < 0.0001, all; Cohen's DL: 2.0, 1.7, 3.0, respectively). Similarly, there was evidence that the predicted mean image quality for the heart, right kidney, and gallbladder was higher for the experimental group compared to the control group (3.46 versus 1.86, 4.49 versus 1.58, and 3.93 versus 1.5, respectively; p < 0.0001, all). There was also evidence that the diagnostic quality of images had a statistically higher predicted probability of meaningful interpretation for the experimental group for pericardial fluid, intraperitoneal fluid, and acute cholecystitis (p = 0.003, p < 0.0001, p < 0.0001, respectively).</p><p><strong>Conclusions: </strong>Tele-guidance improves time to image acquisition and clinical applicability of ultrasound images obtained by untrained scanners.</p>","PeriodicalId":51528,"journal":{"name":"Journal of Ultrasound","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11333636/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ultrasound","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s40477-023-00860-x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/10 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Point-of-care-ultrasound (POCUS) improves diagnostic accuracy and expedites lifesaving procedures. Remote areas disproportionately underuse ultrasound (US) due to a dearth of US trained professionals, imaging tools, and lack of quality assurance. Handheld US probes have been approved for diagnostic imaging but there have been limited studies examining their tele-guidance features. This study investigates whether physician tele-guidance improved ultrasound image acquisition by untrained scanners.

Methods: To determine the effectiveness of tele-guidance for ultrasound image acquisition, 30 participants (15 in each study arm: experimental and control) with no ultrasound or medical experience gathered images of the heart, right kidney, and gallbladder of a standardized patient using a handheld ultrasound probe (Butterfly iQ +). All participants watched a standardized ultrasound tutorial video and were randomized into the control or experimental group. A physician assisted the experimental group using ultrasound probe's tele-guidance feature while the control group received no assistance. Time to image acquisition was recorded for both groups, and the images were graded by 3 blinded radiologists using the RACE tool to determine image and diagnostic quality.

Results: There was evidence that mean imaging time was greater in the control group for the heart, right kidney, and gallbladder (p < 0.0001, all; Cohen's DL: 2.0, 1.7, 3.0, respectively). Similarly, there was evidence that the predicted mean image quality for the heart, right kidney, and gallbladder was higher for the experimental group compared to the control group (3.46 versus 1.86, 4.49 versus 1.58, and 3.93 versus 1.5, respectively; p < 0.0001, all). There was also evidence that the diagnostic quality of images had a statistically higher predicted probability of meaningful interpretation for the experimental group for pericardial fluid, intraperitoneal fluid, and acute cholecystitis (p = 0.003, p < 0.0001, p < 0.0001, respectively).

Conclusions: Tele-guidance improves time to image acquisition and clinical applicability of ultrasound images obtained by untrained scanners.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
远程指导在护理点超声波检查中的应用:一项单中心前瞻性诊断研究。
背景:护理点超声波(POCUS)可提高诊断准确性,加快救生程序。由于缺乏受过超声培训的专业人员和成像工具,以及缺乏质量保证,偏远地区对超声(US)的使用严重不足。手持式 US 探头已被批准用于诊断成像,但对其远程指导功能的研究却很有限。本研究调查了医生远程指导是否改善了未经培训的扫描人员获取超声图像的情况:为了确定远程指导对超声图像采集的有效性,30 名没有超声或医疗经验的参与者(实验组和对照组各 15 人)使用手持式超声探头(Butterfly iQ +)采集了一名标准化患者的心脏、右肾和胆囊图像。所有参与者都观看了标准化的超声波教程视频,并被随机分为对照组和实验组。实验组由一名医生使用超声探头的远程引导功能提供协助,而对照组则不需要任何协助。两组均记录了图像采集时间,并由 3 位盲人放射科医生使用 RACE 工具对图像进行分级,以确定图像和诊断质量:结果:有证据表明,对照组的心脏、右肾和胆囊的平均成像时间更长(p 结论:远程指导可缩短成像时间,提高诊断质量:远程指导缩短了图像采集时间,并提高了未经培训的扫描人员获得的超声图像的临床适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Ultrasound
Journal of Ultrasound RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.10
自引率
15.00%
发文量
133
期刊介绍: The Journal of Ultrasound is the official journal of the Italian Society for Ultrasound in Medicine and Biology (SIUMB). The journal publishes original contributions (research and review articles, case reports, technical reports and letters to the editor) on significant advances in clinical diagnostic, interventional and therapeutic applications, clinical techniques, the physics, engineering and technology of ultrasound in medicine and biology, and in cross-sectional diagnostic imaging. The official language of Journal of Ultrasound is English.
期刊最新文献
Correction: Exploring the potential of contrast agents in breast cancer echography: current state and future directions. Effects of superficial tissue and intermuscular connections on rectus femoris muscle shear modulus heterogeneity. Evaluating acoustic and thermal properties of a plaque phantom. Role of acoustic radiation force impulse elastography of placenta in the diagnosis of pre-eclampsia. Intraobserver reliability and validity of a single ultrasonic measurement of the lateral condyle-capsule distance in the temporomandibular joint.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1