Aravinth Karunanandaa, Joseph Paolillo, Amanda Cook, Kamala Swayampakala, Matthew C Schwartz
{"title":"Changes in left ventricular systolic function after transcatheter patent ductus arteriosus closure in premature infants.","authors":"Aravinth Karunanandaa, Joseph Paolillo, Amanda Cook, Kamala Swayampakala, Matthew C Schwartz","doi":"10.4103/apc.apc_52_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Changes in left ventricular (LV) systolic function have not been well described in premature neonates after transcatheter patent ductus arteriosus (PDA) closure.</p><p><strong>Methods and results: </strong>We retrospectively identified all premature neonates < 3 kg who underwent a transcatheter PDA closure at our center between January 1 2015 and January 31, 2021. LV indices before and after closure were extracted and an analysis was performed. Overall, 23 neonates were included with a mean procedural weight of 1894 ± 622 g. At 24 h after closure, the median left ventricular ejection fraction (LVEF) (66% interquartile range [IQR] 12% vs. 61% IQR 12, <i>P</i>< 0.001) and median LV end-diastolic dimension z-score (3.3 IQR 1.8 vs. 1.4 IQR 2.6, <i>P</i> < 0.001) both decreased and 5 (22%) neonates had an LVEF <55%. Patients who had an LVEF <55% at 24 h had a higher preprocedure LV end-diastolic dimension z-score (4.2 IQR 1.2 vs. 2.8 IQR 1.6, <i>P</i> = 0.01), a higher preprocedure LV end-diastolic volume (19 mL IQR 4 mL vs. 11 mL IQR 11, <i>P</i> = 0.03), a higher birth weight (940 g IQR 100 g vs. 760 g IQR 140, <i>P</i> = 0.04), and were more likely to receive intravenous calcium during the procedure (60% vs. 11%, <i>P</i> = 0.04) compared to those with an LVEF ≥55% at 24 h after closure. Of those with LVEF <55% at 24 h, all normalized before discharge.</p><p><strong>Conclusion: </strong>In preterm neonates who underwent successful transcatheter PDA closure, 23% developed abnormal LVEF after closure and those with significant LV dilation before the procedure were at increased risk for the development of LVEF <55% after closure.</p>","PeriodicalId":8026,"journal":{"name":"Annals of Pediatric Cardiology","volume":"16 4","pages":"260-265"},"PeriodicalIF":0.9000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10856606/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Pediatric Cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/apc.apc_52_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/5 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Changes in left ventricular (LV) systolic function have not been well described in premature neonates after transcatheter patent ductus arteriosus (PDA) closure.
Methods and results: We retrospectively identified all premature neonates < 3 kg who underwent a transcatheter PDA closure at our center between January 1 2015 and January 31, 2021. LV indices before and after closure were extracted and an analysis was performed. Overall, 23 neonates were included with a mean procedural weight of 1894 ± 622 g. At 24 h after closure, the median left ventricular ejection fraction (LVEF) (66% interquartile range [IQR] 12% vs. 61% IQR 12, P< 0.001) and median LV end-diastolic dimension z-score (3.3 IQR 1.8 vs. 1.4 IQR 2.6, P < 0.001) both decreased and 5 (22%) neonates had an LVEF <55%. Patients who had an LVEF <55% at 24 h had a higher preprocedure LV end-diastolic dimension z-score (4.2 IQR 1.2 vs. 2.8 IQR 1.6, P = 0.01), a higher preprocedure LV end-diastolic volume (19 mL IQR 4 mL vs. 11 mL IQR 11, P = 0.03), a higher birth weight (940 g IQR 100 g vs. 760 g IQR 140, P = 0.04), and were more likely to receive intravenous calcium during the procedure (60% vs. 11%, P = 0.04) compared to those with an LVEF ≥55% at 24 h after closure. Of those with LVEF <55% at 24 h, all normalized before discharge.
Conclusion: In preterm neonates who underwent successful transcatheter PDA closure, 23% developed abnormal LVEF after closure and those with significant LV dilation before the procedure were at increased risk for the development of LVEF <55% after closure.