Minjeong Ashley Koo, Hye Yeon Yoon, Jae Hyun Park, So-Hyang Chung, Hyun-Seung Kim, Yong-Soo Byun
{"title":"One-year Outcomes of Ultrathin Descemet Stripping Automated Endothelial Keratoplasty Combined with Cataract Surgery in the Korean Population.","authors":"Minjeong Ashley Koo, Hye Yeon Yoon, Jae Hyun Park, So-Hyang Chung, Hyun-Seung Kim, Yong-Soo Byun","doi":"10.3341/kjo.2023.0101","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the refractive outcomes after ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK) combined with phacoemulsification and intraocular lens implantation (triple procedure) in the South Korean population.</p><p><strong>Methods: </strong>This retrospective observational study included 37 eyes of 36 patients who underwent the UT-DSAEK triple procedure between 2012 and 2021 in a single tertiary hospital. Preoperative and postoperative refractive outcomes and endothelial parameters at 1, 3, 6, and 12 months were observed.</p><p><strong>Results: </strong>At the final postoperative 12-month period, the average best-corrected visual acuity was 0.4 ± 0.5 in logarithm of the minimum angle of resolution. The mean endothelial cell density at 12 months was 1,841.92 ± 731.24 cells/mm2, indicating no significant endothelial cell loss compared to the baseline (p = 0.128). The mean postoperative central corneal thickness at 12 months was 597.41 ± 86.26 μm. The postoperative mean absolute error at 12 months was 0.96 ± 0.89 diopters (D) and mean error was 0.89 ± 0.97 D.</p><p><strong>Conclusions: </strong>The results of our South Korean cohort study on UT-DSAEK triple surgery showed favorable and safe outcomes. Regardless of graft thickness, it should be noted that a hyperopic shift of 1.00 to 2.00 D needs to be considered in the case of UT-DSAEK triple surgery.</p>","PeriodicalId":101356,"journal":{"name":"Korean journal of ophthalmology : KJO","volume":" ","pages":"105-112"},"PeriodicalIF":0.0000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11016680/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean journal of ophthalmology : KJO","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3341/kjo.2023.0101","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/14 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To evaluate the refractive outcomes after ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK) combined with phacoemulsification and intraocular lens implantation (triple procedure) in the South Korean population.
Methods: This retrospective observational study included 37 eyes of 36 patients who underwent the UT-DSAEK triple procedure between 2012 and 2021 in a single tertiary hospital. Preoperative and postoperative refractive outcomes and endothelial parameters at 1, 3, 6, and 12 months were observed.
Results: At the final postoperative 12-month period, the average best-corrected visual acuity was 0.4 ± 0.5 in logarithm of the minimum angle of resolution. The mean endothelial cell density at 12 months was 1,841.92 ± 731.24 cells/mm2, indicating no significant endothelial cell loss compared to the baseline (p = 0.128). The mean postoperative central corneal thickness at 12 months was 597.41 ± 86.26 μm. The postoperative mean absolute error at 12 months was 0.96 ± 0.89 diopters (D) and mean error was 0.89 ± 0.97 D.
Conclusions: The results of our South Korean cohort study on UT-DSAEK triple surgery showed favorable and safe outcomes. Regardless of graft thickness, it should be noted that a hyperopic shift of 1.00 to 2.00 D needs to be considered in the case of UT-DSAEK triple surgery.