Cementing a Monoblock Dual-Mobility Implant into a Fully Porous Cup in Revision Total Hip Arthroplasty to Address Hip Instability: Surgical Technique.

IF 1 Q3 SURGERY JBJS Essential Surgical Techniques Pub Date : 2023-11-22 eCollection Date: 2023-10-01 DOI:10.2106/JBJS.ST.22.00058
Ittai Shichman, Akram A Habibi, Joseph X Robin, Anthony C Gemayel, Dylan T Lowe, Ran Schwarzkopf
{"title":"Cementing a Monoblock Dual-Mobility Implant into a Fully Porous Cup in Revision Total Hip Arthroplasty to Address Hip Instability: Surgical Technique.","authors":"Ittai Shichman, Akram A Habibi, Joseph X Robin, Anthony C Gemayel, Dylan T Lowe, Ran Schwarzkopf","doi":"10.2106/JBJS.ST.22.00058","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The use of a cemented monoblock dual-mobility implant into a fully porous cup is indicated for patients with acetabular bone loss who have a high risk of postoperative hip instability. Patients undergoing lumbar fusion for sagittal spinal deformities have an increased risk of hip dislocation (7.1%) and should be assessed on sitting and standing radiographs<sup>1</sup>. Gabor et al. conducted a multicenter, retrospective study assessing the use of a cemented monoblock dual-mobility bearing in a porous acetabular shell in patients with acetabular bone loss and a high risk of hip instability<sup>2</sup>. Of the 38 patients, 1 (2.6%) experienced a postoperative dislocation that was subsequently treated with closed reduction without further dislocation. This surgical technique represents a favorable surgical option for patients with acetabular bone loss who are at risk for hip instability. In the example case described in the present video article, the patients had a history of dislocations, lumbar fusion, and evidence of Paprosky 3B acetabular defect; as such, the decision was made to revise to a porous shell and cement a monoblock dual-mobility implant.</p><p><strong>Description: </strong>With use of the surgeon's preferred approach, the soft tissue is dissected and the hip is aspirated. The hip is dislocated and a subgluteal pocket is made with use of electrocautery to mobilize the trunnion of the femoral stem to aid in acetabular exposure. The femoral component is assessed to ensure appropriate positioning with adequate anteversion. The acetabular component and any acetabular screws are removed. A \"ream to fit\" technique is performed in the acetabulum until bleeding bone is encountered, with minimal reaming performed in healthy bone from the posterior column. A trial prosthesis is placed within the acetabulum to evaluate if there is satisfactory fixation and if any augment is necessary. Care must be taken during reaming to ensure that enough bone is reamed to accommodate a porous shell that can fit the monoblock dual-mobility implant with a 2-mm cement mantle. Smaller porous shells measuring 56 mm are available for smaller defects but are often not utilized in cases of substantial acetabular bone loss. Fresh-frozen cancellous allograft is utilized to fill any contained defects. The revision porous shell with circumferential screw holes is utilized to allow for screw fixation posterosuperior and anterior toward the pubis. The implants are dried prior to placement of the cement. The cement is applied to the shell and the monoblock dual-mobility implant to ensure adequate coverage. Antibiotic-loaded cement can be utilized according to surgeon preference. Excess cement is removed under direct visualization while the cement is drying, and the position of the dual-mobility implant is adjusted in approximately 20° anteversion and 40° inclination. Stability is assessed after the cement cures, and intraoperative radiography can be performed to confirm cup positioning prior to closure. Any remaining capsule is closed, followed by closure of the remaining soft tissue in a layered fashion.</p><p><strong>Alternatives: </strong>A fully porous multi-hole jumbo cup with conventional polyethylene liner and femoral head can be utilized to increase the jump distance of the femoral head. Constrained, lipped, or offset polyethylene liners can be utilized if the shell is well fixed and a dual-mobility implant cannot be inserted. A cemented dual-mobility implant can be utilized in a well-fixed acetabular shell without evidence of loosening or osteolysis.</p><p><strong>Rationale: </strong>Dual-mobility implants have become increasingly utilized because of their advantages: (1) ability to decrease dislocation rate without increasing constraint and (2) increasing range of motion with reduced impingement risk<sup>2-8</sup>. These implants are particularly useful in the setting of revision cases with large acetabular bone defects. In a study of 76 patients with dual-mobility implants cemented into porous acetabular shells, Muthusamy et al. found that only 3.3% of patients experienced postoperative dislocations<sup>9</sup>. Moreover, acetabular cup survival was excellent, with 100% survival at 1 year and 96.2% at 2 years.</p><p><strong>Expected outcomes: </strong>The use of a dual-mobility implant is a viable treatment option in cases of revision total hip arthroplasty, particularly those in which postoperative stability is a concern; monoblock dual-mobility implants cemented into porous shells are particularly useful in this setting<sup>2-8</sup>. These trends are similarly seen in patients treated with monoblock dual-mobility implants cemented into porous shells. Muthusamy et al. evaluated the use of this construct to treat instability or risk of hip dislocation in 76 hips, reporting a dislocation rate of 3.3% at 2 years. Additionally, the authors reported rates of all-cause acetabular survival from re-revision of 96.7% at 6 months, 93.3% at 1 year, and 89.7% at 2 years<sup>9</sup>. Physicians should be aware of the possibility for intra-prosthetic dislocations, as although this complication is rare, it has been reported in the literature<sup>7,10</sup>.</p><p><strong>Important tips: </strong>In order to allow for circumferential coverage for fixation and ingrowth potential in cases with acetabular defects, the shell is typically impacted slightly vertical (45° to 50° of inclination) and in neutral version (0° to 5° of anteversion). Positioning can be adjusted to improve osseous contact and ingrowth as determined by the size and shape of the defect.The use of a drill guide for the locking screws allows limited degrees of variable screw angulation. In the revision setting, longer screws may be placed posterosuperior toward the sciatic notch or anteroinferior into the pubis. Surgeons should be aware of the anatomy and should predrill holes to reduce the risk of injury to surrounding neurovascular structures such as the obturator artery anteriorly.Any screw holes that are not filled should be covered with plastic hole covers in order to prevent cement from migrating behind the cup. Implants should be dried prior to the placement of the cement, and the cement should be applied to the shell and the dual-mobility implant to ensure adequate coverage.Utilize a monoblock dual-mobility implant that is designed for cementation in order to avoid implant dissociation from the acetabular shell.Remove all fibrous tissue that may hinder bony integration.Assess for pelvis discontinuity; pelvis discontinuity and acetabular bone loss are risk factors in the setting of any revision and should be properly assessed preoperatively and intraoperatively and managed accordingly.Avoid over-reaming and damage of the posterior column.Utilize a reamer or trial to assess defect size and need for augments.Place a compression screw where the cup is in contact with the bone in order to avoid tilting.Cover unused screw holes.</p><p><strong>Acronyms and abbreviations: </strong>THA = total hip arthroplastyS/P = status postTKA = total knee arthroplastyCT = computed tomographyKM = Kaplan MeierDMC = dual-mobility cupPE = polyethylene.</p>","PeriodicalId":44676,"journal":{"name":"JBJS Essential Surgical Techniques","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2023-11-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10863941/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JBJS Essential Surgical Techniques","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2106/JBJS.ST.22.00058","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/10/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The use of a cemented monoblock dual-mobility implant into a fully porous cup is indicated for patients with acetabular bone loss who have a high risk of postoperative hip instability. Patients undergoing lumbar fusion for sagittal spinal deformities have an increased risk of hip dislocation (7.1%) and should be assessed on sitting and standing radiographs1. Gabor et al. conducted a multicenter, retrospective study assessing the use of a cemented monoblock dual-mobility bearing in a porous acetabular shell in patients with acetabular bone loss and a high risk of hip instability2. Of the 38 patients, 1 (2.6%) experienced a postoperative dislocation that was subsequently treated with closed reduction without further dislocation. This surgical technique represents a favorable surgical option for patients with acetabular bone loss who are at risk for hip instability. In the example case described in the present video article, the patients had a history of dislocations, lumbar fusion, and evidence of Paprosky 3B acetabular defect; as such, the decision was made to revise to a porous shell and cement a monoblock dual-mobility implant.

Description: With use of the surgeon's preferred approach, the soft tissue is dissected and the hip is aspirated. The hip is dislocated and a subgluteal pocket is made with use of electrocautery to mobilize the trunnion of the femoral stem to aid in acetabular exposure. The femoral component is assessed to ensure appropriate positioning with adequate anteversion. The acetabular component and any acetabular screws are removed. A "ream to fit" technique is performed in the acetabulum until bleeding bone is encountered, with minimal reaming performed in healthy bone from the posterior column. A trial prosthesis is placed within the acetabulum to evaluate if there is satisfactory fixation and if any augment is necessary. Care must be taken during reaming to ensure that enough bone is reamed to accommodate a porous shell that can fit the monoblock dual-mobility implant with a 2-mm cement mantle. Smaller porous shells measuring 56 mm are available for smaller defects but are often not utilized in cases of substantial acetabular bone loss. Fresh-frozen cancellous allograft is utilized to fill any contained defects. The revision porous shell with circumferential screw holes is utilized to allow for screw fixation posterosuperior and anterior toward the pubis. The implants are dried prior to placement of the cement. The cement is applied to the shell and the monoblock dual-mobility implant to ensure adequate coverage. Antibiotic-loaded cement can be utilized according to surgeon preference. Excess cement is removed under direct visualization while the cement is drying, and the position of the dual-mobility implant is adjusted in approximately 20° anteversion and 40° inclination. Stability is assessed after the cement cures, and intraoperative radiography can be performed to confirm cup positioning prior to closure. Any remaining capsule is closed, followed by closure of the remaining soft tissue in a layered fashion.

Alternatives: A fully porous multi-hole jumbo cup with conventional polyethylene liner and femoral head can be utilized to increase the jump distance of the femoral head. Constrained, lipped, or offset polyethylene liners can be utilized if the shell is well fixed and a dual-mobility implant cannot be inserted. A cemented dual-mobility implant can be utilized in a well-fixed acetabular shell without evidence of loosening or osteolysis.

Rationale: Dual-mobility implants have become increasingly utilized because of their advantages: (1) ability to decrease dislocation rate without increasing constraint and (2) increasing range of motion with reduced impingement risk2-8. These implants are particularly useful in the setting of revision cases with large acetabular bone defects. In a study of 76 patients with dual-mobility implants cemented into porous acetabular shells, Muthusamy et al. found that only 3.3% of patients experienced postoperative dislocations9. Moreover, acetabular cup survival was excellent, with 100% survival at 1 year and 96.2% at 2 years.

Expected outcomes: The use of a dual-mobility implant is a viable treatment option in cases of revision total hip arthroplasty, particularly those in which postoperative stability is a concern; monoblock dual-mobility implants cemented into porous shells are particularly useful in this setting2-8. These trends are similarly seen in patients treated with monoblock dual-mobility implants cemented into porous shells. Muthusamy et al. evaluated the use of this construct to treat instability or risk of hip dislocation in 76 hips, reporting a dislocation rate of 3.3% at 2 years. Additionally, the authors reported rates of all-cause acetabular survival from re-revision of 96.7% at 6 months, 93.3% at 1 year, and 89.7% at 2 years9. Physicians should be aware of the possibility for intra-prosthetic dislocations, as although this complication is rare, it has been reported in the literature7,10.

Important tips: In order to allow for circumferential coverage for fixation and ingrowth potential in cases with acetabular defects, the shell is typically impacted slightly vertical (45° to 50° of inclination) and in neutral version (0° to 5° of anteversion). Positioning can be adjusted to improve osseous contact and ingrowth as determined by the size and shape of the defect.The use of a drill guide for the locking screws allows limited degrees of variable screw angulation. In the revision setting, longer screws may be placed posterosuperior toward the sciatic notch or anteroinferior into the pubis. Surgeons should be aware of the anatomy and should predrill holes to reduce the risk of injury to surrounding neurovascular structures such as the obturator artery anteriorly.Any screw holes that are not filled should be covered with plastic hole covers in order to prevent cement from migrating behind the cup. Implants should be dried prior to the placement of the cement, and the cement should be applied to the shell and the dual-mobility implant to ensure adequate coverage.Utilize a monoblock dual-mobility implant that is designed for cementation in order to avoid implant dissociation from the acetabular shell.Remove all fibrous tissue that may hinder bony integration.Assess for pelvis discontinuity; pelvis discontinuity and acetabular bone loss are risk factors in the setting of any revision and should be properly assessed preoperatively and intraoperatively and managed accordingly.Avoid over-reaming and damage of the posterior column.Utilize a reamer or trial to assess defect size and need for augments.Place a compression screw where the cup is in contact with the bone in order to avoid tilting.Cover unused screw holes.

Acronyms and abbreviations: THA = total hip arthroplastyS/P = status postTKA = total knee arthroplastyCT = computed tomographyKM = Kaplan MeierDMC = dual-mobility cupPE = polyethylene.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在翻修全髋关节置换术中将单体双活动度假体植入全多孔髋臼杯以解决髋关节不稳定性:手术技术。
医生应注意假体内脱位的可能性,尽管这种并发症很少见,但文献中也有报道7,10:重要提示:为了在髋臼缺损的病例中实现周缘覆盖,以利于固定和生长,通常会将髋臼壳撞击至略微垂直(45°至50°的倾斜度),并保持中立(0°至5°的前倾角)。可根据缺损的大小和形状调整位置,以改善骨接触和骨生长。在翻修手术中,可将较长的螺钉放置在坐骨切迹的后上方或耻骨的前下方。外科医生应了解解剖结构,并应预先钻孔,以降低损伤周围神经血管结构(如闭孔动脉前方)的风险。任何未填充的螺钉孔均应用塑料孔盖覆盖,以防止骨水泥从骨杯后方移出。在植入骨水泥之前,应将植入物烘干,并将骨水泥涂抹在髋臼壳和双活动度植入物上,以确保充分覆盖。使用专为骨水泥植入设计的单体双活动度植入物,以避免植入物与髋臼壳分离。评估骨盆不连续性;骨盆不连续性和髋臼骨质流失是任何翻修手术的风险因素,应在术前和术中进行适当评估,并采取相应的管理措施:THA = 全髋关节置换术S/P = 术后状态TKA = 全膝关节置换术CT = 计算机断层扫描KM = Kaplan MeierDMC = 双活动度杯PE = 聚乙烯。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.30
自引率
0.00%
发文量
22
期刊介绍: JBJS Essential Surgical Techniques (JBJS EST) is the premier journal describing how to perform orthopaedic surgical procedures, verified by evidence-based outcomes, vetted by peer review, while utilizing online delivery, imagery and video to optimize the educational experience, thereby enhancing patient care.
期刊最新文献
Bikini Incision Modification of the Direct Anterior Approach. Closed Intramedullary Pinning of Displaced Radial Neck Fracture (Metaizeau Technique). Flexible Intramedullary Nail Placement in Pediatric Humerus Fractures. Ligamentum Flavum Flap Technique in Lumbar Microdiscectomy. Surgery for Pediatric Trigger Finger.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1