A Semi-Automated Pipeline for Nontargeted Compound Analysis via GC×GC-MS

Daniel R. Struk , Rizky Ilhamsyah , Christopher A. Heist , Jean-Marie D. Dimandja , Peter J. Hesketh
{"title":"A Semi-Automated Pipeline for Nontargeted Compound Analysis via GC×GC-MS","authors":"Daniel R. Struk ,&nbsp;Rizky Ilhamsyah ,&nbsp;Christopher A. Heist ,&nbsp;Jean-Marie D. Dimandja ,&nbsp;Peter J. Hesketh","doi":"10.1016/j.jcoa.2024.100118","DOIUrl":null,"url":null,"abstract":"<div><p>A pipeline for the analysis of GC×GC-MS data is presented. The pipeline consists of retention index matching that improves compound identification as well as several methods for removing background compounds of no interest and column bleed. The efficacy of retention index matching is demonstrated via sample mixtures of 26, 26, and 23 compounds. The pipeline in practice is able to reduce the number of matched compounds by half even with lenient screening parameters.</p></div>","PeriodicalId":93576,"journal":{"name":"Journal of chromatography open","volume":"5 ","pages":"Article 100118"},"PeriodicalIF":0.0000,"publicationDate":"2024-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2772391724000057/pdfft?md5=0eab691cc369e8f29b915e9eaa19dc34&pid=1-s2.0-S2772391724000057-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of chromatography open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772391724000057","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A pipeline for the analysis of GC×GC-MS data is presented. The pipeline consists of retention index matching that improves compound identification as well as several methods for removing background compounds of no interest and column bleed. The efficacy of retention index matching is demonstrated via sample mixtures of 26, 26, and 23 compounds. The pipeline in practice is able to reduce the number of matched compounds by half even with lenient screening parameters.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
通过 GC×GC-MS 进行非靶向化合物分析的半自动化管道
本文介绍了一种用于分析 GC×GC-MS 数据的管道。该流程包括可提高化合物识别率的保留指数匹配,以及几种去除无意义背景化合物和色谱柱渗漏的方法。保留指数匹配的功效通过包含 26、26 和 23 种化合物的样品混合物进行了验证。在实际应用中,即使采用宽松的筛选参数,该管道也能将匹配化合物的数量减少一半。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of chromatography open
Journal of chromatography open Analytical Chemistry
CiteScore
2.50
自引率
0.00%
发文量
0
审稿时长
50 days
期刊最新文献
Semi-preparative on-line supercritical fluid extraction-supercritical fluid chromatography for solid-state injection and purification Evaluation of trap discs for root exudate eco-friendly sampling using rhizoboxes: Application to untargeted screening of organic compounds by gas chromatography hyphenated with high resolution mass spectrometry Identifying skin surface chemicals as potential tuberculosis diagnostic biomarkers using ultra performance liquid chromatography-high resolution mass spectrometry Comprehensive characterization and identification of chemical constituents of Pingwei Powder by ultra high performance liquid chromatography tandem quadrupole-time-of-flight tandem mass spectrometry Development of miniaturized autonomous and versatile gas chromatograph for Volatile Organic Compounds monitoring using Nano-Gravimetric-Detector
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1