Quality control data management with unity real-time in molecular virology

IF 4 3区 医学 Q2 VIROLOGY Journal of Clinical Virology Pub Date : 2024-02-12 DOI:10.1016/j.jcv.2024.105655
Mikayla Quinton , Duane W. Newton , Becky Neil , Sondra Mitchell , Heba H. Mostafa
{"title":"Quality control data management with unity real-time in molecular virology","authors":"Mikayla Quinton ,&nbsp;Duane W. Newton ,&nbsp;Becky Neil ,&nbsp;Sondra Mitchell ,&nbsp;Heba H. Mostafa","doi":"10.1016/j.jcv.2024.105655","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Quality control (QC) is one component of an overarching quality management system (QMS) that aims at assuring laboratory quality and patient safety. QC data must be acceptable prior to reporting patients’ results. Traditionally, QC statistics, records, and corrective actions were tracked at the Johns Hopkins Molecular Virology Laboratory using Microsoft Excel. Unity Real-Time (UnityRT), a QMS software (Bio-Rad Laboratories), which captures and analyzes QC data by instrument and control lot per assay, was implemented and its impact on the workflow was evaluated. The clinical utility of real-time QC monitoring using UnityRT is highlighted with a case of subtle QC trending of HIV-1 quantitative control results.</p></div><div><h3>Methods</h3><p>A comprehensive workflow analysis was performed, with a focus on Epstein Barr Virus (EBV) and BKV quantitative viral load testing (Roche cobas 6800). The number of QC steps and time to complete each step were assessed before and after implementing UnityRT.</p></div><div><h3>Results</h3><p>Our assessment of monthly QC data review revealed a total of 10 steps over 57 min when using Microsoft Excel, versus 6 steps over 11 min when using UnityRT. HIV-1 QC monitoring revealed subtle trending of the low positive control above the mean from November to December 2022, correlating with a change in the reagent kit lot. This associated with a shift in patients’ results from positives below the lower limit of quantification to positives between 20 and 100 copies/mL.</p></div><div><h3>Conclusions</h3><p>UnityRT consolidated QC analyses, monitoring, and tracking corrective actions. UnityRT was associated with significant time savings, which along with the interfaced feature of the QC capture and data analysis, have improved the workflow and reduced the risk of laboratory errors. The HIV-1 case revealed the value of the real-time monitoring of QC.</p></div>","PeriodicalId":15517,"journal":{"name":"Journal of Clinical Virology","volume":"171 ","pages":"Article 105655"},"PeriodicalIF":4.0000,"publicationDate":"2024-02-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1386653224000179/pdfft?md5=9735fc96bfffc3d03b339cd08608d485&pid=1-s2.0-S1386653224000179-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Virology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1386653224000179","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VIROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction

Quality control (QC) is one component of an overarching quality management system (QMS) that aims at assuring laboratory quality and patient safety. QC data must be acceptable prior to reporting patients’ results. Traditionally, QC statistics, records, and corrective actions were tracked at the Johns Hopkins Molecular Virology Laboratory using Microsoft Excel. Unity Real-Time (UnityRT), a QMS software (Bio-Rad Laboratories), which captures and analyzes QC data by instrument and control lot per assay, was implemented and its impact on the workflow was evaluated. The clinical utility of real-time QC monitoring using UnityRT is highlighted with a case of subtle QC trending of HIV-1 quantitative control results.

Methods

A comprehensive workflow analysis was performed, with a focus on Epstein Barr Virus (EBV) and BKV quantitative viral load testing (Roche cobas 6800). The number of QC steps and time to complete each step were assessed before and after implementing UnityRT.

Results

Our assessment of monthly QC data review revealed a total of 10 steps over 57 min when using Microsoft Excel, versus 6 steps over 11 min when using UnityRT. HIV-1 QC monitoring revealed subtle trending of the low positive control above the mean from November to December 2022, correlating with a change in the reagent kit lot. This associated with a shift in patients’ results from positives below the lower limit of quantification to positives between 20 and 100 copies/mL.

Conclusions

UnityRT consolidated QC analyses, monitoring, and tracking corrective actions. UnityRT was associated with significant time savings, which along with the interfaced feature of the QC capture and data analysis, have improved the workflow and reduced the risk of laboratory errors. The HIV-1 case revealed the value of the real-time monitoring of QC.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
分子病毒学中的统一实时质量控制数据管理
引言 质量控制(QC)是旨在确保实验室质量和患者安全的总体质量管理系统(QMS)的一个组成部分。在报告患者结果之前,质控数据必须是可接受的。传统上,约翰霍普金斯大学分子病毒学实验室使用 Microsoft Excel 跟踪质控统计数据、记录和纠正措施。Unity Real-Time(UnityRT)是一款质量管理软件(Bio-Rad Laboratories),可按仪器和每次化验的控制批次采集和分析质控数据,该软件已投入使用,并对其对工作流程的影响进行了评估。方法进行了全面的工作流程分析,重点是 Epstein Barr Virus (EBV) 和 BKV 病毒载量定量检测(罗氏 cobas 6800)。结果我们对每月质量控制数据审查进行的评估显示,使用 Microsoft Excel 时总共需要 10 个步骤,耗时 57 分钟,而使用 UnityRT 时只需 6 个步骤,耗时 11 分钟。HIV-1 质量控制监测显示,从 2022 年 11 月到 12 月,低阳性对照出现了高于平均值的微妙趋势,这与试剂盒批次的变化有关。这与患者的检测结果从低于定量下限的阳性转为 20 至 100 copies/mL 之间的阳性有关。UnityRT 节省了大量时间,加上质控采集和数据分析的接口功能,改进了工作流程,降低了实验室出错的风险。HIV-1 案例揭示了质量控制实时监控的价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Clinical Virology
Journal of Clinical Virology 医学-病毒学
CiteScore
22.70
自引率
1.10%
发文量
149
审稿时长
24 days
期刊介绍: The Journal of Clinical Virology, an esteemed international publication, serves as the official journal for both the Pan American Society for Clinical Virology and The European Society for Clinical Virology. Dedicated to advancing the understanding of human virology in clinical settings, the Journal of Clinical Virology focuses on disseminating research papers and reviews pertaining to the clinical aspects of virology. Its scope encompasses articles discussing diagnostic methodologies and virus-induced clinical conditions, with an emphasis on practicality and relevance to clinical practice. The journal publishes on topics that include: • new diagnostic technologies • nucleic acid amplification and serologic testing • targeted and metagenomic next-generation sequencing • emerging pandemic viral threats • respiratory viruses • transplant viruses • chronic viral infections • cancer-associated viruses • gastrointestinal viruses • central nervous system viruses • one health (excludes animal health)
期刊最新文献
Nucleic acid amplification testing using dried blood spots to confirm the diagnosis of HIV-1 in adults. Quantification of human immunodeficiency virus type 2 (HIV-2) viral load in plasma: Comparison of three commercial assays. Coinfections and iterative detection of respiratory viruses among 17,689 patients between March 2021 and December 2022 in Southern France Performance evaluation of the Abbott Alinity Hepatitis C antigen next assay in a US urban emergency department population Standardization and evaluation of an in-house ELISA for the detection of rabies antibody in a tertiary care centre in South India
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1