A82 A SURVEY-BASED ASSESSMENT OF RADIATION PROTECTION ATTITUDES AND PRACTICES IN ADVANCED THERAPEUTIC ENDOSCOPY TRAINING CURRICULUMS

K. Chin Koon Siw, C. Sypkes, M. Gozdzik, H. Dhaliwal, A. Kundra
{"title":"A82 A SURVEY-BASED ASSESSMENT OF RADIATION PROTECTION ATTITUDES AND PRACTICES IN ADVANCED THERAPEUTIC ENDOSCOPY TRAINING CURRICULUMS","authors":"K. Chin Koon Siw, C. Sypkes, M. Gozdzik, H. Dhaliwal, A. Kundra","doi":"10.1093/jcag/gwad061.082","DOIUrl":null,"url":null,"abstract":"Abstract Background Fluoroscopy-assisted endoscopic procedures such as endoscopic retrograde cholangiopancreatography (ERCP) expose patients and physicians to the risks of ionizing radiation, including infertility, cataracts, skin hypersensitivity, hair loss and cancer. Radiation exposure from these procedures can have lasting adverse effects on the health and productivity of gastroenterologists. With attention to “as low as reasonably achievable” (ALARA) principles, recent efforts to minimize radiation use have emphasized the importance of formal radiation protection education, including during advanced therapeutic endoscopy (ATE) training. However, teaching of basic protective measures in radiation safety during ATE training remains often overlooked. Aims We aimed to learn how radiation safety training is delivered in ATE programs across Canada and the US. Identifying the existing training standards and knowledge will help us understand the current gaps in training curriculums and inform future curricular development. Methods Our study was reviewed by the Ottawa Health Science Network Research Ethics Board in September 2023. Surveys were designed and distributed with the REDCap software and sent to ATE trainees (current and recent graduates within the last 3 years) in Canada and Program Directors (PDs) of accredited ATE programs across Canada and the US. Results The survey was completed by 12 trainees and 4 PDs. These are preliminary results and further survey responses are being collected. The majority of trainees (75%) believed it would be very important for their program’s curriculum to include dedicated radiation safety teaching, but most trainees (83.3%) received no such training. Familiarity in optimizing modifiable fluoroscopy parameters to minimize radiation exposure (collimation, gain, magnification, frame rate modification or pulsed fluoroscopy) was variable among trainees (36.4%-81.8%). Seventy-five percent of trainees were unaware of the annual limit for radiation exposure and only 25% believed they were operating within a safe level. Most trainees (90.9%) felt they were given inadequate training to optimally reduce their risk of radiation exposure and 90.9% expressed a desire for further radiation safety training. Despite these findings, only 50% of PDs believed it would be beneficial to offer dedicated radiation safety training as part of their program’s curriculum. Among PDs, 75% did not feel their trainees had the knowledge required to reduce their risk of radiation exposure and all (100%) felt that dedicated training would be useful. Conclusions These findings indicate a need for more robust radiation safety training. Further studies are needed to understand the most effective way to deliver comprehensive radiation safety training to ATE trainees. Funding Agencies None","PeriodicalId":508018,"journal":{"name":"Journal of the Canadian Association of Gastroenterology","volume":"63 ","pages":"57 - 58"},"PeriodicalIF":0.0000,"publicationDate":"2024-02-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Canadian Association of Gastroenterology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jcag/gwad061.082","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Background Fluoroscopy-assisted endoscopic procedures such as endoscopic retrograde cholangiopancreatography (ERCP) expose patients and physicians to the risks of ionizing radiation, including infertility, cataracts, skin hypersensitivity, hair loss and cancer. Radiation exposure from these procedures can have lasting adverse effects on the health and productivity of gastroenterologists. With attention to “as low as reasonably achievable” (ALARA) principles, recent efforts to minimize radiation use have emphasized the importance of formal radiation protection education, including during advanced therapeutic endoscopy (ATE) training. However, teaching of basic protective measures in radiation safety during ATE training remains often overlooked. Aims We aimed to learn how radiation safety training is delivered in ATE programs across Canada and the US. Identifying the existing training standards and knowledge will help us understand the current gaps in training curriculums and inform future curricular development. Methods Our study was reviewed by the Ottawa Health Science Network Research Ethics Board in September 2023. Surveys were designed and distributed with the REDCap software and sent to ATE trainees (current and recent graduates within the last 3 years) in Canada and Program Directors (PDs) of accredited ATE programs across Canada and the US. Results The survey was completed by 12 trainees and 4 PDs. These are preliminary results and further survey responses are being collected. The majority of trainees (75%) believed it would be very important for their program’s curriculum to include dedicated radiation safety teaching, but most trainees (83.3%) received no such training. Familiarity in optimizing modifiable fluoroscopy parameters to minimize radiation exposure (collimation, gain, magnification, frame rate modification or pulsed fluoroscopy) was variable among trainees (36.4%-81.8%). Seventy-five percent of trainees were unaware of the annual limit for radiation exposure and only 25% believed they were operating within a safe level. Most trainees (90.9%) felt they were given inadequate training to optimally reduce their risk of radiation exposure and 90.9% expressed a desire for further radiation safety training. Despite these findings, only 50% of PDs believed it would be beneficial to offer dedicated radiation safety training as part of their program’s curriculum. Among PDs, 75% did not feel their trainees had the knowledge required to reduce their risk of radiation exposure and all (100%) felt that dedicated training would be useful. Conclusions These findings indicate a need for more robust radiation safety training. Further studies are needed to understand the most effective way to deliver comprehensive radiation safety training to ATE trainees. Funding Agencies None
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A82 基于调查的高级治疗内窥镜培训课程中辐射防护态度和实践评估
摘要 背景 内镜逆行胰胆管造影术(ERCP)等荧光内镜辅助手术使患者和医生面临电离辐射的风险,包括不育、白内障、皮肤过敏、脱发和癌症。这些手术的辐射照射会对肠胃病学家的健康和工作效率产生持久的不利影响。随着对 "尽可能低"(ALARA)原则的关注,最近为尽量减少辐射使用所做的努力强调了正规辐射防护教育的重要性,包括在高级治疗内镜(ATE)培训期间。然而,在 ATE 培训期间,辐射安全基本防护措施的教学仍经常被忽视。目的 我们旨在了解加拿大和美国的 ATE 项目是如何开展辐射安全培训的。确定现有的培训标准和知识将有助于我们了解目前培训课程中存在的差距,并为今后的课程开发提供参考。方法 我们的研究于 2023 年 9 月通过了渥太华健康科学网络研究伦理委员会的审查。我们使用 REDCap 软件设计和分发了调查问卷,并将其发送给加拿大的 ATE 学员(在校生和近三年内的应届毕业生)以及加拿大和美国经认可的 ATE 项目的项目主任(PDs)。结果 12 名学员和 4 名项目主任完成了调查。这些都是初步结果,目前正在收集更多的调查回复。大多数受训人员(75%)认为,他们所在项目的课程中包含专门的辐射安全教学非常重要,但大多数受训人员(83.3%)没有接受过此类培训。受训人员(36.4%-81.8%)对优化可修改的透视参数以尽量减少辐射暴露(准直、增益、放大、帧频修改或脉冲透视)的熟悉程度各不相同。75%的受训人员不知道辐射量的年度限制,只有25%的受训人员认为他们的操作在安全范围内。大多数受训人员(90.9%)认为他们接受的培训不足以最大限度地降低辐照风险,90.9%的受训人员表示希望接受进一步的辐射安全培训。尽管有这些发现,但只有 50%的专业人员认为在其专业课程中提供专门的辐射安全培训是有益的。在专业人员中,75%的人认为他们的学员不具备降低辐照风险所需的知识,而所有专业人员(100%)都认为专门的培训是有用的。结论 这些研究结果表明,有必要开展更有力的辐射安全培训。还需要进一步研究,以了解向 ATE 受训人员提供全面辐射安全培训的最有效方法。资助机构 无
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Contemporary epidemiology of hepatocellular carcinoma: understanding risk factors and surveillance strategies Identification and prioritization of patient-centred strategies to enhance IBD-related care for older adults: a modified Delphi approach Rectal varices treated by retrograde transvenous obliteration Canadian colorectal cancer screening programs: How do they measure up using the International Agency for Research on Cancer criteria for organized screening? A78 VALIDITY EVIDENCE FOR OBSERVATIONAL EUS COMPETENCY ASSESSMENT: A SYSTEMATIC REVIEW
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1