Flexible Pressure Sensor Based on Carbon Black/PVDF Nanocomposite

Victor K. Samoei, A. Jayatissa, Keiichiro Sano
{"title":"Flexible Pressure Sensor Based on Carbon Black/PVDF Nanocomposite","authors":"Victor K. Samoei, A. Jayatissa, Keiichiro Sano","doi":"10.9734/csji/2024/v33i2885","DOIUrl":null,"url":null,"abstract":"A piezoresistive flexible pressure sensor was fabricated using carbon black and Poly (vinylidene fluoride) (CB/PVDF) composite. The conductive CB/PVDF composite was prepared by a wet-cast method and deposited onto a flexible polyethylene (PE) substrate. The surface morphology, crystal structure, and material properties were studied using SEM and X-ray diffraction methods. This flexible pressure sensor was tested in a wide pressure range of about 0 - 76 kPa, and its response time was less than 0.43 s. The sensitivity, response time, and recovery time were studied for different pressures and vibration modes. The repeatability and reproducibility characteristics of the sensors were studied, and it was found that the sensors exhibited excellent characteristics. The sensor was subjected to different loading and unloading pressures, and the resistance of the sensor remained stable, indicating that the sensor had a high degree of reproducibility. Owing to its flexible properties and the materials used, the proposed device can be applied in the next generation of smart sensors for biomedical, robotic, and automotive sensing applications.","PeriodicalId":502866,"journal":{"name":"Chemical Science International Journal","volume":"148 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemical Science International Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9734/csji/2024/v33i2885","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A piezoresistive flexible pressure sensor was fabricated using carbon black and Poly (vinylidene fluoride) (CB/PVDF) composite. The conductive CB/PVDF composite was prepared by a wet-cast method and deposited onto a flexible polyethylene (PE) substrate. The surface morphology, crystal structure, and material properties were studied using SEM and X-ray diffraction methods. This flexible pressure sensor was tested in a wide pressure range of about 0 - 76 kPa, and its response time was less than 0.43 s. The sensitivity, response time, and recovery time were studied for different pressures and vibration modes. The repeatability and reproducibility characteristics of the sensors were studied, and it was found that the sensors exhibited excellent characteristics. The sensor was subjected to different loading and unloading pressures, and the resistance of the sensor remained stable, indicating that the sensor had a high degree of reproducibility. Owing to its flexible properties and the materials used, the proposed device can be applied in the next generation of smart sensors for biomedical, robotic, and automotive sensing applications.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于炭黑/PVDF 纳米复合材料的柔性压力传感器
利用炭黑和聚(偏二氟乙烯)(CB/PVDF)复合材料制作了压阻柔性压力传感器。导电 CB/PVDF 复合材料采用湿法浇铸制备,并沉积在柔性聚乙烯(PE)基底上。利用 SEM 和 X 射线衍射方法研究了其表面形貌、晶体结构和材料特性。该柔性压力传感器在 0 - 76 kPa 的宽压力范围内进行了测试,其响应时间小于 0.43 秒。对传感器的重复性和再现性特征进行了研究,结果发现传感器表现出优异的特性。传感器经受了不同的加载和卸载压力,其电阻保持稳定,这表明传感器具有很高的再现性。由于其灵活的特性和所使用的材料,所提出的装置可应用于生物医学、机器人和汽车传感应用的下一代智能传感器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Determination of the Electronic Structure, Charge-transfer, and Optical Properties of Neutral, Anionic, and Cationic Perfluoropentacene Phytochemical Analysis and Investigation of the Antibacterial and Antioxidant Activities of Aristolochia albida Root Extracts Overall Summery of Gulf Country Employees from Bangladesh, Preliminary Evaluation for Abnormal Kidney Liver and Virally Infected Individuals Using Low-cost Tests Like CBC Parameters Examining the Electron Phase Transformation Theory in the Context of Atomic Structure Stability Indicating RP-HPLC Method Development and Validation for Imeglimin HCL in Pharmaceutical Dosage form
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1