A. E. F. Oliveira, Arnaldo César Pereira, Mayra A. C. Resende, L. F. Ferreira
{"title":"Disposable Voltammetric Immunosensor for Determination and Quantification of Biomarker CA 15-3 in Biological Specimens","authors":"A. E. F. Oliveira, Arnaldo César Pereira, Mayra A. C. Resende, L. F. Ferreira","doi":"10.3390/analytica5010005","DOIUrl":null,"url":null,"abstract":"A disposable voltammetric immunosensor was developed to measure breast cancer biomarker 15-3 (CA 15-3) in human saliva and serum samples. Screen-printed paper-based electrodes (f-SPE) previously fabricated by our research group using homemade conductive inks were used as transducers, which were later modified only with gold nanoparticles to immobilize anti-CA 15-3 antibodies. The sensor was operated using antigen–antibody interactions in conjunction with a redox species (ferrocyanide potassium) for the indirect determination of the CA 15-3 antigen. The device characterization involved atomic force microscopy (AFM) and electrochemical analysis. Optimization of the construction and response of the immunosensor was achieved at incubation times of 6 h for anti-CA 15-3, 1 h for bovine serum albumin, and 1 h for interaction with CA 15-3. The sensor displays a linear range between 2 and 16 U/mL, with a sensitivity of 0.012 μA/U mL−1, a limit of detection (LOD) of 0.56 U/mL, and a limit of quantification (LOQ) of 1.88 U/mL. The interfering substances minimally affected the signal, with 4.94% response variation, and the reproducibility of the immunosensor demonstrated a relative standard deviation (RSD) of 5.65%. The sensor successfully determined the CA 15-3 concentration in human serum and saliva, demonstrating its potential for clinical analysis.","PeriodicalId":7829,"journal":{"name":"Analytica","volume":"84 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/analytica5010005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
A disposable voltammetric immunosensor was developed to measure breast cancer biomarker 15-3 (CA 15-3) in human saliva and serum samples. Screen-printed paper-based electrodes (f-SPE) previously fabricated by our research group using homemade conductive inks were used as transducers, which were later modified only with gold nanoparticles to immobilize anti-CA 15-3 antibodies. The sensor was operated using antigen–antibody interactions in conjunction with a redox species (ferrocyanide potassium) for the indirect determination of the CA 15-3 antigen. The device characterization involved atomic force microscopy (AFM) and electrochemical analysis. Optimization of the construction and response of the immunosensor was achieved at incubation times of 6 h for anti-CA 15-3, 1 h for bovine serum albumin, and 1 h for interaction with CA 15-3. The sensor displays a linear range between 2 and 16 U/mL, with a sensitivity of 0.012 μA/U mL−1, a limit of detection (LOD) of 0.56 U/mL, and a limit of quantification (LOQ) of 1.88 U/mL. The interfering substances minimally affected the signal, with 4.94% response variation, and the reproducibility of the immunosensor demonstrated a relative standard deviation (RSD) of 5.65%. The sensor successfully determined the CA 15-3 concentration in human serum and saliva, demonstrating its potential for clinical analysis.