{"title":"Infliximab Therapeutic monitoring by tryptic peptide LC-MS/MS method improvements lead to improved accuracy with decreased imprecision and turnaround time","authors":"Paula M. Ladwig,&nbsp;Ann L. Rivard,&nbsp;Alex Barbeln,&nbsp;Anthony Maus,&nbsp;David L. Murray,&nbsp;Melissa R. Snyder,&nbsp;Maria A.V. Willrich","doi":"10.1016/j.jmsacl.2024.01.007","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Therapeutic drug monitoring of infliximab has become the standard of care for inflammatory bowel disease in the setting of loss of response to therapy, and occasionally in proactive therapy personalization. Measurement of infliximab by tryptic peptide HPLC-MS/MS has been available since 2015, mostly in reference laboratories.</p></div><div><h3>Objectives</h3><p>Here, we present method improvements to our original published method leading to a more efficient, robust, and high throughput tryptic peptide HPLC-MS/MS assay for infliximab quantitation.</p></div><div><h3>Methods</h3><p>Deidentified residual serum samples submitted for clinical testing were used for method comparison and infliximab was spiked into normal human serum for performance studies. Improvements included the addition of a stable isotope labeled full length infliximab internal standard (IS) replacing a surrogate IS, and immunoenrichment using Melon Gel for immunoglobulins replacing the saturated ammonium sulfate precipitation. Digestion and chromatography were optimized, and automation was added. The method improvements were validated to include precision, accuracy, reportable range, linearity, and analytical sensitivity.</p></div><div><h3>Results</h3><p>The digestion time was reduced from overnight to 1 h. The assay analytical measuring range (AMR) remained the same throughout improvements, 1–100 µg/mL, with linearity of 0.98x + 0.50, R<sup>2</sup> = 1.00. Intra- and inter-assay imprecision were less than 5 % CV at four different concentrations. Accuracy was assessed with 106 patients within the AMR; Passing-Bablok Regression yielded a slope of 1.00 and a y-intercept of 0.25. Turnaround time was reduced by 1 day, and imprecision of three levels of quality control trended down after new method implementation.</p></div><div><h3>Conclusions</h3><p>Method improvements including automation have allowed for assay completion in half a day, improving robustness and turnaround time.</p></div>","PeriodicalId":52406,"journal":{"name":"Journal of Mass Spectrometry and Advances in the Clinical Lab","volume":"32 ","pages":"Pages 24-30"},"PeriodicalIF":3.1000,"publicationDate":"2024-02-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2667145X24000075/pdfft?md5=0c58d3c575ab46fb712891706560a876&pid=1-s2.0-S2667145X24000075-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Mass Spectrometry and Advances in the Clinical Lab","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2667145X24000075","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction

Therapeutic drug monitoring of infliximab has become the standard of care for inflammatory bowel disease in the setting of loss of response to therapy, and occasionally in proactive therapy personalization. Measurement of infliximab by tryptic peptide HPLC-MS/MS has been available since 2015, mostly in reference laboratories.

Objectives

Here, we present method improvements to our original published method leading to a more efficient, robust, and high throughput tryptic peptide HPLC-MS/MS assay for infliximab quantitation.

Methods

Deidentified residual serum samples submitted for clinical testing were used for method comparison and infliximab was spiked into normal human serum for performance studies. Improvements included the addition of a stable isotope labeled full length infliximab internal standard (IS) replacing a surrogate IS, and immunoenrichment using Melon Gel for immunoglobulins replacing the saturated ammonium sulfate precipitation. Digestion and chromatography were optimized, and automation was added. The method improvements were validated to include precision, accuracy, reportable range, linearity, and analytical sensitivity.

Results

The digestion time was reduced from overnight to 1 h. The assay analytical measuring range (AMR) remained the same throughout improvements, 1–100 µg/mL, with linearity of 0.98x + 0.50, R2 = 1.00. Intra- and inter-assay imprecision were less than 5 % CV at four different concentrations. Accuracy was assessed with 106 patients within the AMR; Passing-Bablok Regression yielded a slope of 1.00 and a y-intercept of 0.25. Turnaround time was reduced by 1 day, and imprecision of three levels of quality control trended down after new method implementation.

Conclusions

Method improvements including automation have allowed for assay completion in half a day, improving robustness and turnaround time.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
通过胰肽 LC-MS/MS 方法改进英夫利西单抗治疗监测,提高了准确性,减少了不精确度,缩短了周转时间
导言英夫利昔单抗的治疗药物监测已成为治疗炎症性肠病的标准方法,可用于治疗反应消失的情况,有时也可用于主动个性化治疗。在此,我们介绍了对最初发表的方法进行的改进,从而开发出一种更高效、更稳健、高通量的胰蛋白酶肽 HPLC-MS/MS 分析方法,用于英夫利昔单抗的定量分析。方法将提交临床检测的身份识别残留血清样本用于方法比较,并将英夫利昔单抗添加到正常人血清中进行性能研究。改进之处包括添加了稳定同位素标记的全长英夫利西单抗内标(IS)以取代替代内标,并使用免疫球蛋白瓜胶(Melon Gel)进行免疫富集以取代饱和硫酸铵沉淀。对消化和色谱法进行了优化,并增加了自动化功能。结果消化时间从过夜缩短到 1 小时。在整个改进过程中,测定分析量程 (AMR) 保持不变,为 1-100 µg/mL,线性度为 0.98x + 0.50,R2 = 1.00。在四种不同浓度下,测定内和测定间的不精确度均小于 5 % CV。对 AMR 中的 106 名患者进行了准确性评估;Passing-Bablok 回归得出的斜率为 1.00,y-截距为 0.25。新方法实施后,周转时间缩短了 1 天,三级质量控制的不精确度呈下降趋势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Mass Spectrometry and Advances in the Clinical Lab
Journal of Mass Spectrometry and Advances in the Clinical Lab Health Professions-Medical Laboratory Technology
CiteScore
4.30
自引率
18.20%
发文量
41
审稿时长
81 days
期刊最新文献
Tandem mass spectrometry of serum cholestanoic (C27) acids – Typical concentration ranges and application to the study of peroxisomal biogenesis disorders Research letter: Pilot study of a prototype fully automated mass spectrometry system for routine clinical laboratory use Method validation of an inductively coupled plasma mass spectrometry (ICP-MS) assay for the analysis of magnesium, copper and zinc in red blood cells Liquid chromatography-mass spectrometric method for the simultaneous analysis of branched-chain amino acids and their ketoacids from dried blood spot as secondary analytes for the detection of maple syrup urine disease Development and validation of an LC-MS/MS method for highly concentrated tacrolimus and cyclosporine samples prepared from pharmaceutical products to assess drug loss from feeding tubes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1