Surface wear of attachments in patients during clear aligner therapy: a prospective clinical study.

IF 4.8 2区 医学 Q1 Dentistry Progress in Orthodontics Pub Date : 2024-02-19 DOI:10.1186/s40510-023-00506-y
Qiuying Li, Kai Yang
{"title":"Surface wear of attachments in patients during clear aligner therapy: a prospective clinical study.","authors":"Qiuying Li, Kai Yang","doi":"10.1186/s40510-023-00506-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This prospective clinical study aimed to quantitatively evaluate the surface wear of attachments and investigate the associated risk factors. Additionally, the wear values and regions of three types of commonly used attachments were explored.</p><p><strong>Methods: </strong>Participants were recruited from the population of patients who received clear aligner therapy from October to December 2022. Intraoral scanning was performed on eligible participants before treatment (T0), immediately after initial bonding of attachments (T1), and at 2 months (T2), 4 months (T3), 6 months (T4), and 8 months (T5) after starting treatment. The attachment volume, average depth and regions of attachment wear were measured using superimposed digitized models. The Kruskal-Wallis test was performed to compare data between multiple groups. Multiple linear regression analyses were performed to evaluate risk factors for the volume of attachment wear.</p><p><strong>Results: </strong>A total of 47 patients with 617 attachments were included. As treatment time increased, the attachment volume decreased significantly (P = 0.003). The initial attachment volume was positively related to the volume of attachment wear (β = 0.527, P < 0.001). The volume of attachment wear was significantly greater in females than in males (β = 0.147, P = 0.020) and in optimized attachments than in conventional attachments (β = 0.308, P < 0.001). The wear of 3-mm rectangular attachments progressed from edges to buccal surfaces, with the deepest wear at corners of gingival edges; the wear of the optimized attachments was primarily located on surface ridges. The wear volume ratio of the optimized root control attachments was significantly greater than that of the 3-mm rectangular attachments at T3 (P = 0.011), T4 (P < 0.001), and T5 (P < 0.001).</p><p><strong>Conclusions: </strong>The volume of attachment wear increased gradually with treatment time. Sex, attachment type, and initial attachment volume were risk factors for the volume of attachment wear. The deepest wear regions of 3-mm rectangular attachments were at the corners of gingival edges, while the deepest wear regions of optimized attachments were at surface ridges. Four months after treatment, optimized root control attachments showed more relative wear than 3-mm rectangular attachments.</p>","PeriodicalId":56071,"journal":{"name":"Progress in Orthodontics","volume":"25 1","pages":"7"},"PeriodicalIF":4.8000,"publicationDate":"2024-02-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10874919/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Progress in Orthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40510-023-00506-y","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Background: This prospective clinical study aimed to quantitatively evaluate the surface wear of attachments and investigate the associated risk factors. Additionally, the wear values and regions of three types of commonly used attachments were explored.

Methods: Participants were recruited from the population of patients who received clear aligner therapy from October to December 2022. Intraoral scanning was performed on eligible participants before treatment (T0), immediately after initial bonding of attachments (T1), and at 2 months (T2), 4 months (T3), 6 months (T4), and 8 months (T5) after starting treatment. The attachment volume, average depth and regions of attachment wear were measured using superimposed digitized models. The Kruskal-Wallis test was performed to compare data between multiple groups. Multiple linear regression analyses were performed to evaluate risk factors for the volume of attachment wear.

Results: A total of 47 patients with 617 attachments were included. As treatment time increased, the attachment volume decreased significantly (P = 0.003). The initial attachment volume was positively related to the volume of attachment wear (β = 0.527, P < 0.001). The volume of attachment wear was significantly greater in females than in males (β = 0.147, P = 0.020) and in optimized attachments than in conventional attachments (β = 0.308, P < 0.001). The wear of 3-mm rectangular attachments progressed from edges to buccal surfaces, with the deepest wear at corners of gingival edges; the wear of the optimized attachments was primarily located on surface ridges. The wear volume ratio of the optimized root control attachments was significantly greater than that of the 3-mm rectangular attachments at T3 (P = 0.011), T4 (P < 0.001), and T5 (P < 0.001).

Conclusions: The volume of attachment wear increased gradually with treatment time. Sex, attachment type, and initial attachment volume were risk factors for the volume of attachment wear. The deepest wear regions of 3-mm rectangular attachments were at the corners of gingival edges, while the deepest wear regions of optimized attachments were at surface ridges. Four months after treatment, optimized root control attachments showed more relative wear than 3-mm rectangular attachments.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
透明矫形器治疗过程中患者附着体表面的磨损:一项前瞻性临床研究。
研究背景这项前瞻性临床研究旨在定量评估附着体的表面磨损情况,并调查相关的风险因素。此外,还探讨了三种常用附着体的磨损值和磨损区域:从2022年10月至12月接受透明矫治器治疗的患者中招募参与者。对符合条件的参与者在治疗前(T0)、初次粘结附着体后立即(T1)、开始治疗后2个月(T2)、4个月(T3)、6个月(T4)和8个月(T5)进行口内扫描。使用叠加的数字化模型测量附着体体积、平均深度和附着体磨损区域。采用 Kruskal-Wallis 检验比较多组之间的数据。进行多元线性回归分析以评估附着磨损量的风险因素:结果:共纳入了 47 名患者和 617 个附着体。随着治疗时间的延长,附着量明显减少(P = 0.003)。初始附着量与附着磨损量呈正相关(β = 0.527,P 结论:随着治疗时间的延长,附着磨损量逐渐增加:随着治疗时间的延长,附着磨损量逐渐增加。性别、附着类型和初始附着量是附着磨损量的危险因素。3 毫米矩形附着体磨损最深的区域位于牙龈边缘的角落,而优化附着体磨损最深的区域位于表面脊。治疗四个月后,优化的根控附着体比 3 毫米矩形附着体显示出更多的相对磨损。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Progress in Orthodontics
Progress in Orthodontics Dentistry-Orthodontics
CiteScore
7.30
自引率
4.20%
发文量
45
审稿时长
13 weeks
期刊介绍: Progress in Orthodontics is a fully open access, international journal owned by the Italian Society of Orthodontics and published under the brand SpringerOpen. The Society is currently covering all publication costs so there are no article processing charges for authors. It is a premier journal of international scope that fosters orthodontic research, including both basic research and development of innovative clinical techniques, with an emphasis on the following areas: • Mechanisms to improve orthodontics • Clinical studies and control animal studies • Orthodontics and genetics, genomics • Temporomandibular joint (TMJ) control clinical trials • Efficacy of orthodontic appliances and animal models • Systematic reviews and meta analyses • Mechanisms to speed orthodontic treatment Progress in Orthodontics will consider for publication only meritorious and original contributions. These may be: • Original articles reporting the findings of clinical trials, clinically relevant basic scientific investigations, or novel therapeutic or diagnostic systems • Review articles on current topics • Articles on novel techniques and clinical tools • Articles of contemporary interest
期刊最新文献
Effect of anti-sclerostin antibody on orthodontic tooth movement in ovariectomized rats. Seeking orderness out of the orderless movements: an up-to-date review of the biomechanics in clear aligners. Age-stratified assessment of orthodontic tooth movement outcomes with clear aligners. The role of orthodontists in the multidisciplinary management of obstructive sleep apnea. Polymerization kinetics of 3D-printed orthodontic aligners under different UV post-curing conditions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1