Simone Garzon, Antonio Simone Laganà, Stefano Guerriero, Juan Luis Alcázar, Susan Dababou, Stefano Uccella, Marco Scioscia
{"title":"Transvaginal Sonography for the Preoperative Assessment of Parametrial Deep Infiltrating Endometriosis: A Diagnostic Accuracy Study.","authors":"Simone Garzon, Antonio Simone Laganà, Stefano Guerriero, Juan Luis Alcázar, Susan Dababou, Stefano Uccella, Marco Scioscia","doi":"10.1159/000535940","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The aim of the study was to evaluate the diagnostic accuracy for parametria endometriosis (PE) of transvaginal sonography (TVS) performed following a systematic approach for the assessment of the lateral parametria.</p><p><strong>Design: </strong>A diagnostic accuracy study was employed based on a prospective observational design.</p><p><strong>Participants: </strong>All consecutive patients who underwent laparoscopic surgery for endometriosis between January 2016 and December 2020 were considered.</p><p><strong>Setting: </strong>The study was conducted at endometriosis referral hospitals.</p><p><strong>Methods: </strong>We prospectively collected clinical, imaging, and surgical data of all consecutive patients who underwent laparoscopic surgery for endometriosis between January 2016 and December 2020. A standardized technique with a systematic approach for the assessment of the lateral parametria following specific anatomic landmarks was used for the TVS. The diagnostic accuracy for PE in TVS was assessed using the intraoperative and pathologic diagnosis of PE as the gold standard.</p><p><strong>Results: </strong>In 476 patients who underwent surgery, PE was identified in 114 out of 476 patients (23.95%): 91 left and 54 right PE out of 476 surgical procedures were identified (19.12% vs. 11.34%; p = 0.001); bilateral involvement in 27.19% (31/114 patients) cases. The sensitivity of TVS for PE was 90.74% (79.70-96.92%, 95% CI) for the right side and 87.91% (79.40-93.81%, 95% CI) for the left side. The specificity was almost identical for both sides (98.58% vs. 98.18%). For the right parametrium, the positive likelihood ratio (PLR) and negative likelihood ratio (NLR) were 63.82 (28.70-141.90, 95% CI) and 0.09 (0.04-0.22, 95% CI), respectively. On the left parametrium, the PLR and NLR were 48.35 (23.12-101.4, 95% CI) and 0.12 (0.07-0.21, 95% CI), respectively. The diagnostic accuracy for right and left PE was 97.69% (95.90-98.84%, 95% CI) and 96.22% (94.04-97.74%, 95% CI), respectively.</p><p><strong>Limitations: </strong>The principal limit is the high dependence of TVS on the operator experience. Therefore, although a standardized approach following precise definitions of anatomical landmarks was used, we cannot conclude that the observed accuracy of TVS for PE is the same for all sonographers. In this regard, the learning curve was not assessed. In the case of negative TVS for parametrial involvement with an absent intraoperative suspect, a complete dissection of the parametrium was not performed to avoid surgical complications; therefore, cases of minor PE may be missed, underestimating false negatives.</p><p><strong>Conclusions: </strong>TVS performed following a systematic approach for assessing the lateral parametria seems to have good diagnostic accuracy for PE with large changes in the posttest probability of parametrial involvement based on the TVS evaluation. Considering the clinical and surgical implications of PE, further studies implementing a standardized approach for assessing the parametrium by TVS are recommended to confirm our observations and implement a standardized protocol in clinical practice.</p>","PeriodicalId":12952,"journal":{"name":"Gynecologic and Obstetric Investigation","volume":" ","pages":"111-119"},"PeriodicalIF":2.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gynecologic and Obstetric Investigation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000535940","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/20 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: The aim of the study was to evaluate the diagnostic accuracy for parametria endometriosis (PE) of transvaginal sonography (TVS) performed following a systematic approach for the assessment of the lateral parametria.
Design: A diagnostic accuracy study was employed based on a prospective observational design.
Participants: All consecutive patients who underwent laparoscopic surgery for endometriosis between January 2016 and December 2020 were considered.
Setting: The study was conducted at endometriosis referral hospitals.
Methods: We prospectively collected clinical, imaging, and surgical data of all consecutive patients who underwent laparoscopic surgery for endometriosis between January 2016 and December 2020. A standardized technique with a systematic approach for the assessment of the lateral parametria following specific anatomic landmarks was used for the TVS. The diagnostic accuracy for PE in TVS was assessed using the intraoperative and pathologic diagnosis of PE as the gold standard.
Results: In 476 patients who underwent surgery, PE was identified in 114 out of 476 patients (23.95%): 91 left and 54 right PE out of 476 surgical procedures were identified (19.12% vs. 11.34%; p = 0.001); bilateral involvement in 27.19% (31/114 patients) cases. The sensitivity of TVS for PE was 90.74% (79.70-96.92%, 95% CI) for the right side and 87.91% (79.40-93.81%, 95% CI) for the left side. The specificity was almost identical for both sides (98.58% vs. 98.18%). For the right parametrium, the positive likelihood ratio (PLR) and negative likelihood ratio (NLR) were 63.82 (28.70-141.90, 95% CI) and 0.09 (0.04-0.22, 95% CI), respectively. On the left parametrium, the PLR and NLR were 48.35 (23.12-101.4, 95% CI) and 0.12 (0.07-0.21, 95% CI), respectively. The diagnostic accuracy for right and left PE was 97.69% (95.90-98.84%, 95% CI) and 96.22% (94.04-97.74%, 95% CI), respectively.
Limitations: The principal limit is the high dependence of TVS on the operator experience. Therefore, although a standardized approach following precise definitions of anatomical landmarks was used, we cannot conclude that the observed accuracy of TVS for PE is the same for all sonographers. In this regard, the learning curve was not assessed. In the case of negative TVS for parametrial involvement with an absent intraoperative suspect, a complete dissection of the parametrium was not performed to avoid surgical complications; therefore, cases of minor PE may be missed, underestimating false negatives.
Conclusions: TVS performed following a systematic approach for assessing the lateral parametria seems to have good diagnostic accuracy for PE with large changes in the posttest probability of parametrial involvement based on the TVS evaluation. Considering the clinical and surgical implications of PE, further studies implementing a standardized approach for assessing the parametrium by TVS are recommended to confirm our observations and implement a standardized protocol in clinical practice.
期刊介绍:
This journal covers the most active and promising areas of current research in gynecology and obstetrics. Invited, well-referenced reviews by noted experts keep readers in touch with the general framework and direction of international study. Original papers report selected experimental and clinical investigations in all fields related to gynecology, obstetrics and reproduction. Short communications are published to allow immediate discussion of new data. The international and interdisciplinary character of this periodical provides an avenue to less accessible sources and to worldwide research for investigators and practitioners.