{"title":"[Development of a Three-Wavelength Brain Tissue Oxygen Monitoring System Based on Near Infrared Spectrum].","authors":"Zexi Li, Hanlin Li, Qi Yin, Shijie Cai, Jilun Ye, Xu Zhang, Hui Yu, Dahai Gou","doi":"10.3969/j.issn.1671-7104.230207","DOIUrl":null,"url":null,"abstract":"<p><p>In the past 20 years, near infrared spectrum technology has been widely used in human body monitoring due to its non-invasive and real-time characteristics. Oxygen, as the main metabolic substance of the human body, is consumed the most in brain tissue. In order to prevent complications caused by a decrease in brain tissue oxygen during treatment, the patient's brain tissue blood oxygen saturation needs to be monitored in real time. Currently, most of the clinically used non-invasive cerebral blood oxygen detection equipments use dual wavelengths. Other substances on the detection path will cause errors in the measurement results. Therefore, this article proposes a three-wavelength method based on the basic principle of non-invasive monitoring of cerebral blood oxygen using near-infrared spectrum. The brain tissue oxygen saturation monitoring method of detecting light sources was initially verified through the built system, laying the foundation for subsequent system engineering.</p>","PeriodicalId":52535,"journal":{"name":"中国医疗器械杂志","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-01-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国医疗器械杂志","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.3969/j.issn.1671-7104.230207","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
In the past 20 years, near infrared spectrum technology has been widely used in human body monitoring due to its non-invasive and real-time characteristics. Oxygen, as the main metabolic substance of the human body, is consumed the most in brain tissue. In order to prevent complications caused by a decrease in brain tissue oxygen during treatment, the patient's brain tissue blood oxygen saturation needs to be monitored in real time. Currently, most of the clinically used non-invasive cerebral blood oxygen detection equipments use dual wavelengths. Other substances on the detection path will cause errors in the measurement results. Therefore, this article proposes a three-wavelength method based on the basic principle of non-invasive monitoring of cerebral blood oxygen using near-infrared spectrum. The brain tissue oxygen saturation monitoring method of detecting light sources was initially verified through the built system, laying the foundation for subsequent system engineering.