{"title":"Serum reference intervals of micronutrients, vitamins, and interleukins among healthy adults in South-Western Nigeria","authors":"Tewogbade Adeoye Adedeji , Nife Olamide Adedeji , Olusola Akanni Jeje , Abiodun Kofoworola Ajeigbe , Olufemi Samuel Smith , Temilola O. Owojuyigbe , Michael Bimbo Fawale , Olabamiji Abiodun Ajose , Simeon Adelani Adebisi , Adeyinka Abdulrasak Akande , Bashiru Adekunle Okesina","doi":"10.1016/j.plabm.2024.e00363","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><p>Clinical decision making depends mostly on appropriate application of numerical pathology reports from laboratory results, interpreted by comparison with reference intervals. We determined serum reference intervals of micronutrients, vitamins, and detectable interleukins among healthy adults in South-Western Nigeria.</p></div><div><h3>Design and methods</h3><p>This prospective study used a priori selection approach in blood-donors. They were screened for conditions that could elicit cytokine production.</p><p>Serum micronutrients were assayed using Atomic Absorption Spectrophotometry; interleukins and vitamins by high Performance Liquid Chromatography. The reference intervals (RIs) were estimated at 2.5th percentile and 97.5th percentile.</p></div><div><h3>Results</h3><p>One hundred and eighteen (118) apparently healthy subjects, aged 18–56 years; 113 (95.8%) being 18–44years, and 5 (4.2%): 45–56 years; mostly males, 13 (11.02%) females, all Africans of Yoruba ethnicity.</p><p>Estimated reference limits were: Zinc: 9.49–20.54 μmol/L, Selenium: 0.50–1.11 μmol/L, Copper: 13.86–27.97 μmol/L, Iron: 14.19–32.07 μmol/L, Manganese: 6.24–16.37 nmol/L; Magnesium: 0.78–1.62 mmol/L.</p><p>Vitamins: A-1.08–2.39 μmol/L; D: 59.89–164.42 μmol/L; E: 7.13–19.45 μmol/L; K: 0.16–0.42 nmol/L; B1: 74.09–201.56 nmol/L; B6: 0.12–0.29 nmol/L; B12: 155.55–407.96 pmol/L; C: 47.74–112.99 μmol/L.</p><p>Detected interleukins (IL-1 to IL-18): IL-1: 0.58–1.24 ng/L, IL-2: 0.09–0.18 ng/L, IL-3: 0.39–0.89 ng/L, IL-4: 0.27–0.58 ng/L, ….to IL-18: 0.74–1.56 ng/L.</p></div><div><h3>Conclusions</h3><p>The RI derived from this study for serum micronutrient, vitamin and interleukin concentrations are the first published for our population. They are in general agreement with those published from other geographical climes but there are differences at the lower and upper limits of the RI. The study reinforces the importance of deriving RI for the population that a clinical laboratory will serve.</p></div>","PeriodicalId":20421,"journal":{"name":"Practical Laboratory Medicine","volume":"39 ","pages":"Article e00363"},"PeriodicalIF":1.7000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S235255172400009X/pdfft?md5=a8282da3efb4b7eed07aa21db50ae45e&pid=1-s2.0-S235255172400009X-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Practical Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S235255172400009X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives
Clinical decision making depends mostly on appropriate application of numerical pathology reports from laboratory results, interpreted by comparison with reference intervals. We determined serum reference intervals of micronutrients, vitamins, and detectable interleukins among healthy adults in South-Western Nigeria.
Design and methods
This prospective study used a priori selection approach in blood-donors. They were screened for conditions that could elicit cytokine production.
Serum micronutrients were assayed using Atomic Absorption Spectrophotometry; interleukins and vitamins by high Performance Liquid Chromatography. The reference intervals (RIs) were estimated at 2.5th percentile and 97.5th percentile.
Results
One hundred and eighteen (118) apparently healthy subjects, aged 18–56 years; 113 (95.8%) being 18–44years, and 5 (4.2%): 45–56 years; mostly males, 13 (11.02%) females, all Africans of Yoruba ethnicity.
The RI derived from this study for serum micronutrient, vitamin and interleukin concentrations are the first published for our population. They are in general agreement with those published from other geographical climes but there are differences at the lower and upper limits of the RI. The study reinforces the importance of deriving RI for the population that a clinical laboratory will serve.
期刊介绍:
Practical Laboratory Medicine is a high-quality, peer-reviewed, international open-access journal publishing original research, new methods and critical evaluations, case reports and short papers in the fields of clinical chemistry and laboratory medicine. The objective of the journal is to provide practical information of immediate relevance to workers in clinical laboratories. The primary scope of the journal covers clinical chemistry, hematology, molecular biology and genetics relevant to laboratory medicine, microbiology, immunology, therapeutic drug monitoring and toxicology, laboratory management and informatics. We welcome papers which describe critical evaluations of biomarkers and their role in the diagnosis and treatment of clinically significant disease, validation of commercial and in-house IVD methods, method comparisons, interference reports, the development of new reagents and reference materials, reference range studies and regulatory compliance reports. Manuscripts describing the development of new methods applicable to laboratory medicine (including point-of-care testing) are particularly encouraged, even if preliminary or small scale.