Marco Taurisano, Andrea Mancini, Filomena D'elia, Giuseppe Gernone, Cosma Cortese
{"title":"[Calcified Fibrin Sheath After Stuck Catheter Removal: Case Report and Literature Review].","authors":"Marco Taurisano, Andrea Mancini, Filomena D'elia, Giuseppe Gernone, Cosma Cortese","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The prevalence of central venous catheters (CVC) in hemodialysis patients is around 20-30%. In this scenario, complications related to the use of the CVC are commonly observed, requiring active management by nephrologists. These include infectious complications as well as those related to CVC malfunction. Among the latter, the formation of a fibrin sheath around the catheter linked to foreign body reaction could cause CVC malfunction in various ways. Even after the removal of the catheter, the fibrin sheath can remain inside the vascular lumen (ghost fibrin sheath) and rarely undergo calcification. We describe the clinical case of a hemodialysis patient who, following the removal of a malfunctioning, stuck CVC, presented a calcified tubular structure in the lumen of the superior vena cava, diagnosed as calcified fibrin sheath (CFS). This rare occurrence, described in the literature in 8 other cases, although rare, is certainly underdiagnosed and can lead to complications such as sepsis resulting from CFS, pulmonary embolisms, and vascular thrombosis. Therapeutic approaches should be considered only in symptomatic cases and involve an invasive surgical approach.</p>","PeriodicalId":12553,"journal":{"name":"Giornale italiano di nefrologia : organo ufficiale della Societa italiana di nefrologia","volume":"41 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Giornale italiano di nefrologia : organo ufficiale della Societa italiana di nefrologia","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
The prevalence of central venous catheters (CVC) in hemodialysis patients is around 20-30%. In this scenario, complications related to the use of the CVC are commonly observed, requiring active management by nephrologists. These include infectious complications as well as those related to CVC malfunction. Among the latter, the formation of a fibrin sheath around the catheter linked to foreign body reaction could cause CVC malfunction in various ways. Even after the removal of the catheter, the fibrin sheath can remain inside the vascular lumen (ghost fibrin sheath) and rarely undergo calcification. We describe the clinical case of a hemodialysis patient who, following the removal of a malfunctioning, stuck CVC, presented a calcified tubular structure in the lumen of the superior vena cava, diagnosed as calcified fibrin sheath (CFS). This rare occurrence, described in the literature in 8 other cases, although rare, is certainly underdiagnosed and can lead to complications such as sepsis resulting from CFS, pulmonary embolisms, and vascular thrombosis. Therapeutic approaches should be considered only in symptomatic cases and involve an invasive surgical approach.
期刊介绍:
Il Giornale Italiano di Nefrologia (GIN) è la rivista di educazione continua della Società Italiana di Nefrologia SIN ed è pubblicato bimestralmente. E" il più autorevole organo di informazione nefrologia disponibile a livello nazionale. Il giornale Italiano di Nefrologia offre la più aggiornata informazione medico-scientifica rivolta al nefrologo sotto forma di rassegne, casi clinici e articoli finalizzati all’Educazione Continua in Medicina, oltre ai notiziari ed agli atti dei congressi di questa prestigiosa Società Scientifica