Key parameters of gob-side entry retaining by roof cutting in close-distance seam group

IF 3.9 2区 工程技术 Q3 ENERGY & FUELS Geomechanics and Geophysics for Geo-Energy and Geo-Resources Pub Date : 2024-02-29 DOI:10.1007/s40948-024-00772-y
Chaowen Hu, Xiaojie Yang, Qian Li, Bing Hu, Yongyuan Li, Qi Jiang, Fulong Sun
{"title":"Key parameters of gob-side entry retaining by roof cutting in close-distance seam group","authors":"Chaowen Hu, Xiaojie Yang, Qian Li, Bing Hu, Yongyuan Li, Qi Jiang, Fulong Sun","doi":"10.1007/s40948-024-00772-y","DOIUrl":null,"url":null,"abstract":"<p>During the process of close-distance seam group mining, the coal pillar in the upper coal seam is a stress-concentrated area, which leads to a loss of stability of the roadway during mining of the lower coal seam. This lack of stability introduces great safety hazards to coal mines. To solve the problem of stress concentration of coal pillars, the method of gob-side entry retaining by roof cutting is proposed to remove the coal pillar. In this study, FLAC3D was used to analyze the depth and angle of pre-split blasting. LS-DYNA was used to analyze the spacing of the blasthole. Using the methods of theoretical analysis and numerical simulation, we determined that the optimal depth of the pre-split blasting was 6 m, the optimal angle for pre-split blasting was 15°, and the optimal spacing of the blasthole was 500 mm. A field test was carried out in the 1010201 ventilation roadway of the Yuwang Coal Mine, China. The on-site peeping results showed that when the spacing of the blasthole is 500 mm, connecting cracks can form under the action of blasting stress. After the working surface is mined, the roof strata could collapse and fill the gob over time when the depth and angle of the pre-split blasting are 6 m and 15°, respectively.</p>","PeriodicalId":12813,"journal":{"name":"Geomechanics and Geophysics for Geo-Energy and Geo-Resources","volume":"23 1","pages":""},"PeriodicalIF":3.9000,"publicationDate":"2024-02-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Geomechanics and Geophysics for Geo-Energy and Geo-Resources","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s40948-024-00772-y","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

Abstract

During the process of close-distance seam group mining, the coal pillar in the upper coal seam is a stress-concentrated area, which leads to a loss of stability of the roadway during mining of the lower coal seam. This lack of stability introduces great safety hazards to coal mines. To solve the problem of stress concentration of coal pillars, the method of gob-side entry retaining by roof cutting is proposed to remove the coal pillar. In this study, FLAC3D was used to analyze the depth and angle of pre-split blasting. LS-DYNA was used to analyze the spacing of the blasthole. Using the methods of theoretical analysis and numerical simulation, we determined that the optimal depth of the pre-split blasting was 6 m, the optimal angle for pre-split blasting was 15°, and the optimal spacing of the blasthole was 500 mm. A field test was carried out in the 1010201 ventilation roadway of the Yuwang Coal Mine, China. The on-site peeping results showed that when the spacing of the blasthole is 500 mm, connecting cracks can form under the action of blasting stress. After the working surface is mined, the roof strata could collapse and fill the gob over time when the depth and angle of the pre-split blasting are 6 m and 15°, respectively.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
近距接缝组通过顶板切割保留鹅卵石边入口的主要参数
在近距离煤层群开采过程中,上煤层的煤柱是应力集中区,导致下煤层开采时巷道失去稳定性。这种不稳定性给煤矿带来了极大的安全隐患。为了解决煤柱应力集中的问题,提出了通过顶板切割保留煤柱的方法来清除煤柱。本研究采用 FLAC3D 分析了预裂爆破的深度和角度。采用 LS-DYNA 分析爆破孔间距。通过理论分析和数值模拟,我们确定最佳预裂爆破深度为 6 米,最佳预裂爆破角度为 15°,最佳爆破孔间距为 500 毫米。在中国禹王煤矿 1010201 通风巷道进行了现场试验。现场窥探结果表明,当爆破孔间距为 500 毫米时,在爆破应力的作用下会形成连通裂缝。工作面开采完毕后,当预裂爆破深度和角度分别为 6 米和 15°时,顶板地层会随着时间的推移而坍塌并填满裂隙。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Geomechanics and Geophysics for Geo-Energy and Geo-Resources
Geomechanics and Geophysics for Geo-Energy and Geo-Resources Earth and Planetary Sciences-Geophysics
CiteScore
6.40
自引率
16.00%
发文量
163
期刊介绍: This journal offers original research, new developments, and case studies in geomechanics and geophysics, focused on energy and resources in Earth’s subsurface. Covers theory, experimental results, numerical methods, modeling, engineering, technology and more.
期刊最新文献
Numerical analysis of the influence of quartz crystal anisotropy on the thermal–mechanical coupling behavior of monomineral quartzite Failure analysis of Nehbandan granite under various stress states and strain rates using a calibrated Riedel–Hiermaier–Thoma constitutive model Fracture propagation characteristics of layered shale oil reservoirs with dense laminas under cyclic pressure shock fracturing Numerical simulation of hydraulic fracture propagation from recompletion in refracturing with dynamic stress modeling Criterion for hydraulic fracture propagation behaviour at coal measure composite reservoir interface based on energy release rate theory
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1