Early experience with a 3-D printed porous surface, fixed-bearing, total ankle arthroplasty: A minimum of 2-year follow-up

IF 1.9 3区 医学 Q2 ORTHOPEDICS Foot and Ankle Surgery Pub Date : 2024-07-01 DOI:10.1016/j.fas.2024.02.008
Joseph Duff, Jordan Dunson, Jesse F. Doty
{"title":"Early experience with a 3-D printed porous surface, fixed-bearing, total ankle arthroplasty: A minimum of 2-year follow-up","authors":"Joseph Duff,&nbsp;Jordan Dunson,&nbsp;Jesse F. Doty","doi":"10.1016/j.fas.2024.02.008","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>This is a pilot study reviewing patients undergoing ankle replacement with the 3-D printed INFINITY™ with ADAPTIS™ total ankle arthroplasty (TAA) system.</p></div><div><h3>Methods</h3><p>A retrospective review was conducted of patients with a minimum two-year follow-up who underwent TAA with the INFINITY™ with ADAPTIS™ implant system. Outcome measures include implant survivorship, complications with subsequent reoperations, patient reported outcomes, and radiologic subsidence or radiolucency.</p></div><div><h3>Results</h3><p>Thirty patients were included with median follow-up of 26 months (range, 24–36). Implant survival rate was 90% (27/30). Two patients experienced linear radiolucency &gt; 2 mm: one required a revision TAA secondary to tibial subsidence; the other patient was asymptomatic and nonprogressive on serial radiographs. No cystic radiolucencies &gt; 5 mm were identified. VAS, PROMIS PF, and FADI scores improved significantly.</p></div><div><h3>Conclusion</h3><p>TAA performed with the 3-D printed INFINITY™ with ADAPTIS™ implant technology led to ninety percent short term implant survivorship and improvement in patient reported outcomes with comparable results to other 4th generation arthroplasty systems as a treatment modality for end-stage ankle arthritis.</p></div><div><h3>Level of evidence</h3><p>Level III, Retrospective cohort study, Prognostic</p></div>","PeriodicalId":48743,"journal":{"name":"Foot and Ankle Surgery","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Foot and Ankle Surgery","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1268773124000353","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background

This is a pilot study reviewing patients undergoing ankle replacement with the 3-D printed INFINITY™ with ADAPTIS™ total ankle arthroplasty (TAA) system.

Methods

A retrospective review was conducted of patients with a minimum two-year follow-up who underwent TAA with the INFINITY™ with ADAPTIS™ implant system. Outcome measures include implant survivorship, complications with subsequent reoperations, patient reported outcomes, and radiologic subsidence or radiolucency.

Results

Thirty patients were included with median follow-up of 26 months (range, 24–36). Implant survival rate was 90% (27/30). Two patients experienced linear radiolucency > 2 mm: one required a revision TAA secondary to tibial subsidence; the other patient was asymptomatic and nonprogressive on serial radiographs. No cystic radiolucencies > 5 mm were identified. VAS, PROMIS PF, and FADI scores improved significantly.

Conclusion

TAA performed with the 3-D printed INFINITY™ with ADAPTIS™ implant technology led to ninety percent short term implant survivorship and improvement in patient reported outcomes with comparable results to other 4th generation arthroplasty systems as a treatment modality for end-stage ankle arthritis.

Level of evidence

Level III, Retrospective cohort study, Prognostic

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
3-D 打印多孔表面固定轴承全踝关节成形术的早期经验:至少两年的随访
这是一项试验性研究,对使用 3-D 打印 INFINITY™ with ADAPTIS™ 全踝关节置换术(TAA)系统进行踝关节置换的患者进行回顾性研究。该研究对使用 INFINITY™ with ADAPTIS™ 植入系统接受踝关节置换术的患者进行了至少两年的回顾性研究。结果指标包括植入物存活率、随后再次手术的并发症、患者报告的结果以及放射学沉降或放射透明。30 名患者的中位随访时间为 26 个月(24-36 个月)。植入物存活率为 90%(27/30)。有两名患者的线性放射影大于 2 毫米:其中一名患者因胫骨下陷而需要进行 TAA 翻修术;另一名患者无症状,连续拍片检查也无进展。没有发现直径大于 5 毫米的囊性放射性肿物。VAS、PROMIS PF和FADI评分明显改善。使用带有 ADAPTIS™ 植入物技术的 3-D 打印 INFINITY™ 进行 TAA 手术后,植入物的短期存活率达到 90%,患者报告的结果也有所改善,与其他 4 代关节成形系统作为治疗终末期踝关节炎的方法相比,效果相当。III级,回顾性队列研究,预后性
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Foot and Ankle Surgery
Foot and Ankle Surgery ORTHOPEDICS-
CiteScore
4.60
自引率
16.00%
发文量
202
期刊介绍: Foot and Ankle Surgery is essential reading for everyone interested in the foot and ankle and its disorders. The approach is broad and includes all aspects of the subject from basic science to clinical management. Problems of both children and adults are included, as is trauma and chronic disease. Foot and Ankle Surgery is the official journal of European Foot and Ankle Society. The aims of this journal are to promote the art and science of ankle and foot surgery, to publish peer-reviewed research articles, to provide regular reviews by acknowledged experts on common problems, and to provide a forum for discussion with letters to the Editors. Reviews of books are also published. Papers are invited for possible publication in Foot and Ankle Surgery on the understanding that the material has not been published elsewhere or accepted for publication in another journal and does not infringe prior copyright.
期刊最新文献
Comparative biomechanical study of different screw fixation methods for minimally invasive hallux valgus surgery: A finite element analysis. Younger age correlates with increased gutter impingement rates after total ankle arthroplasty. The clinical outcome comparison between trans-syndesmotic fixation and anatomic deltoid ligament repair in unstable ankle fractures with medial clear space widening: A systematic review and meta-analysis. Use of computer-assisted hexapod external fixators for complex foot and ankle reconstructions - An analysis of functional outcomes and complications. Large language models and common patient concerns on hallux valgus: Comment.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1