New extreme ultraviolet transmission measurements of two thin-film filters for imaging of plasmaspheric cold ions

IF 1.7 3区 工程技术 Q2 ENGINEERING, AEROSPACE Journal of Astronomical Telescopes Instruments and Systems Pub Date : 2024-03-01 DOI:10.1117/1.jatis.10.1.015003
Philippa Molyneux, Todd Veach, Michael Davis, Gregory Fletcher, Jerry Goldstein
{"title":"New extreme ultraviolet transmission measurements of two thin-film filters for imaging of plasmaspheric cold ions","authors":"Philippa Molyneux, Todd Veach, Michael Davis, Gregory Fletcher, Jerry Goldstein","doi":"10.1117/1.jatis.10.1.015003","DOIUrl":null,"url":null,"abstract":"We present extreme ultraviolet (EUV) transmission measurements of two thin-film filters designed to obtain improved images of plasmaspheric He+, and the first global images of O+/O++ in the dense oxygen torus. Compared to previous He+ 30.4 nm imaging that used an Al filter, we show that a combined Al+C filter achieves superior rejection of 58.4 nm background from neutral helium (He I). We show that an indium filter provides both the required transmission at 83.4 nm and adequate rejection of brighter He I (58.4 nm) and H I (121.6 nm) background emissions. We find that the In transmission at 58.4 nm is a factor of ∼16 lower than predicted based on optical constants that rely on interpolations at λ<68 nm. We show that the observed lower 58.4 nm transmission is consistent with alternative optical constants derived from previous lab measurements.","PeriodicalId":54342,"journal":{"name":"Journal of Astronomical Telescopes Instruments and Systems","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Astronomical Telescopes Instruments and Systems","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1117/1.jatis.10.1.015003","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, AEROSPACE","Score":null,"Total":0}
引用次数: 0

Abstract

We present extreme ultraviolet (EUV) transmission measurements of two thin-film filters designed to obtain improved images of plasmaspheric He+, and the first global images of O+/O++ in the dense oxygen torus. Compared to previous He+ 30.4 nm imaging that used an Al filter, we show that a combined Al+C filter achieves superior rejection of 58.4 nm background from neutral helium (He I). We show that an indium filter provides both the required transmission at 83.4 nm and adequate rejection of brighter He I (58.4 nm) and H I (121.6 nm) background emissions. We find that the In transmission at 58.4 nm is a factor of ∼16 lower than predicted based on optical constants that rely on interpolations at λ<68 nm. We show that the observed lower 58.4 nm transmission is consistent with alternative optical constants derived from previous lab measurements.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于质球冷离子成像的两款薄膜滤光片的新型极紫外透射测量结果
我们展示了两款薄膜滤光片的极紫外(EUV)透射测量结果,这两款滤光片的设计目的是获得更好的质球He+图像,以及致密氧环中O+/O++的首批全局图像。与之前使用铝滤光片的 He+ 30.4 nm 成像相比,我们发现铝+碳组合滤光片能更好地抑制来自中性氦(He I)的 58.4 nm 背景。我们的研究表明,铟滤光片既能满足 83.4 纳米波长的透射要求,又能充分抑制较亮的 He I(58.4 纳米波长)和 H I(121.6 纳米波长)背景发射。我们发现,58.4 nm 波长处的铟透射率比根据 λ<68 nm 处的内插光学常数预测的值低 ∼ 16 倍。我们表明,观测到的较低的 58.4 nm 波长透射率与以前实验室测量得出的其他光学常数是一致的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.40
自引率
13.00%
发文量
119
期刊介绍: The Journal of Astronomical Telescopes, Instruments, and Systems publishes peer-reviewed papers reporting on original research in the development, testing, and application of telescopes, instrumentation, techniques, and systems for ground- and space-based astronomy.
期刊最新文献
Design, implementation, and performance of the primary reflector for SALTUS Solar system science with the Single Aperture Large Telescope for Universe Studies space observatory Milky Way and nearby galaxy science with the SALTUS space observatory Adjustable X-ray optics: thin-film actuator measurement and figure correction performance FIREBall-2 UV balloon telescope in-flight calibration system
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1