Adeline Baron , Alice Moisan , Guillemette Unal , Véronique Lemée , Manuel Etienne , Jean-Christophe Plantier
{"title":"Evaluation of the ELITechGroup solution for plasma HIV-1 RNA quantification","authors":"Adeline Baron , Alice Moisan , Guillemette Unal , Véronique Lemée , Manuel Etienne , Jean-Christophe Plantier","doi":"10.1016/j.jcv.2024.105663","DOIUrl":null,"url":null,"abstract":"<div><p>In the last few years, many manufacturers have developed new kits for plasma HIV-1 RNA quantification. Recently, a solution consisting of the ELITe InGenius® instrument and the HIV1 ELITe MGB®kit has been commercialized worldwide. Our aim was to compare its clinical performance with the Aptima® HIV-1 Quant Dx kit by Hologic, on a panel of HIV-1 group M circulating variants, representative of viral load levels found during the pre- and post-treatment follow-up of patients. The linearity was evaluated on the AcroMetrix® HIV-1 Panel. Clinical specificity was evaluated on 100 plasma samples negative for HIV; and clinical sensitivity and sequential follow-up were evaluated on 166 HIV-1 positive plasma samples from 126 patients. The linearity data showed a difference obtained for each point of less than 0.2 Log cp/mL. No amplification was found for the 100 HIV negative clinical specimens. The overall agreement between the two kits was 83.7 %; the differences corresponded to a slightly higher detection for the Aptima kit (with more samples detected below the lower limit of quantification). A Bland & Altman analysis of the quantifiable samples showed a mean difference of −0.05 Log and Spearman's coefficient was 0.975. Only six samples presented discrepancies (above 0.5 Log), but these differences were overall similar between the two kits. Our study has shown that the HIV1 ELITe MGB® Kit can be successfully used for the monitoring of patients infected with various epidemic HIV-1 strains, and for the precise quantification of the viral load.</p></div>","PeriodicalId":15517,"journal":{"name":"Journal of Clinical Virology","volume":"173 ","pages":"Article 105663"},"PeriodicalIF":4.0000,"publicationDate":"2024-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1386653224000258/pdfft?md5=38f71e94941f74678398f058f65734eb&pid=1-s2.0-S1386653224000258-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Virology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1386653224000258","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VIROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
In the last few years, many manufacturers have developed new kits for plasma HIV-1 RNA quantification. Recently, a solution consisting of the ELITe InGenius® instrument and the HIV1 ELITe MGB®kit has been commercialized worldwide. Our aim was to compare its clinical performance with the Aptima® HIV-1 Quant Dx kit by Hologic, on a panel of HIV-1 group M circulating variants, representative of viral load levels found during the pre- and post-treatment follow-up of patients. The linearity was evaluated on the AcroMetrix® HIV-1 Panel. Clinical specificity was evaluated on 100 plasma samples negative for HIV; and clinical sensitivity and sequential follow-up were evaluated on 166 HIV-1 positive plasma samples from 126 patients. The linearity data showed a difference obtained for each point of less than 0.2 Log cp/mL. No amplification was found for the 100 HIV negative clinical specimens. The overall agreement between the two kits was 83.7 %; the differences corresponded to a slightly higher detection for the Aptima kit (with more samples detected below the lower limit of quantification). A Bland & Altman analysis of the quantifiable samples showed a mean difference of −0.05 Log and Spearman's coefficient was 0.975. Only six samples presented discrepancies (above 0.5 Log), but these differences were overall similar between the two kits. Our study has shown that the HIV1 ELITe MGB® Kit can be successfully used for the monitoring of patients infected with various epidemic HIV-1 strains, and for the precise quantification of the viral load.
期刊介绍:
The Journal of Clinical Virology, an esteemed international publication, serves as the official journal for both the Pan American Society for Clinical Virology and The European Society for Clinical Virology. Dedicated to advancing the understanding of human virology in clinical settings, the Journal of Clinical Virology focuses on disseminating research papers and reviews pertaining to the clinical aspects of virology. Its scope encompasses articles discussing diagnostic methodologies and virus-induced clinical conditions, with an emphasis on practicality and relevance to clinical practice.
The journal publishes on topics that include:
• new diagnostic technologies
• nucleic acid amplification and serologic testing
• targeted and metagenomic next-generation sequencing
• emerging pandemic viral threats
• respiratory viruses
• transplant viruses
• chronic viral infections
• cancer-associated viruses
• gastrointestinal viruses
• central nervous system viruses
• one health (excludes animal health)