{"title":"Improving multi-pinhole CZT myocardial perfusion imaging specificity without changing sensibility by using adapted filter parameters.","authors":"Fabien Vauchot, Julien Dubois, Aurélie Bourdon","doi":"10.1186/s13550-024-01083-9","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Meta-analysis show the diagnostic performance of cardiac dedicated multi-pinhole cadmium-zinc-telluride myocardial perfusion imaging (MPI) with a sensibility around 0.9 and a specificity around 0.7. The aim of the present study is to explore a simple method to generate less artefact on MPI using single photon emission computed tomography (SPECT) and to enhance specificity without changing sensibility.</p><p><strong>Results: </strong>From October 2018 to March 2019, 200 patients who underwent SPECT with [<sup>99m</sup>Tc]Tc-tetrofosmin were prospectively recruited: 100 patients with ischemia or necrosis diagnosis (first arm), and 100 patients with myocardial reversible SPECT artefact (second arm). Each SPECT was explored using two image process based on a Butterworth prefilter and post-filter: the original image processing (reconstruction A) with a cut-off frequency equals to 37% of the Nyquist frequency and order equals to 7, and a second image processing (reconstruction B) with a cut-off frequency equals to 25% of the Nyquist frequency and order equals to 5. For each patient, sum stress or rest score with and without septum (SSRS and SSRSws) were calculated with the two reconstructions. No significant statistical difference between SSRSa and SSRSb was identified for the first arm (P = 0.54) and the relative difference ∆r was - 0.5 ± 11.1% (95% CI - 2.7 to 1.7). We found a significant statistical difference between SSRSa and SSRSb for the second arm (p < 0.0001) and the relative difference ∆r was 69.7 ± 16.2% (95% CI 66.6-72.9).</p><p><strong>Conclusion: </strong>In conclusion, using a Butterworth prefilter and post-filter cut-off frequency equal to 25% of the Nyquist frequency before iterative reconstruction generates less artefact and improves myocardial SPECT specificity without affecting sensibility compared with the original reconstruction.</p>","PeriodicalId":11611,"journal":{"name":"EJNMMI Research","volume":"14 1","pages":"27"},"PeriodicalIF":3.1000,"publicationDate":"2024-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10920588/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EJNMMI Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13550-024-01083-9","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Meta-analysis show the diagnostic performance of cardiac dedicated multi-pinhole cadmium-zinc-telluride myocardial perfusion imaging (MPI) with a sensibility around 0.9 and a specificity around 0.7. The aim of the present study is to explore a simple method to generate less artefact on MPI using single photon emission computed tomography (SPECT) and to enhance specificity without changing sensibility.
Results: From October 2018 to March 2019, 200 patients who underwent SPECT with [99mTc]Tc-tetrofosmin were prospectively recruited: 100 patients with ischemia or necrosis diagnosis (first arm), and 100 patients with myocardial reversible SPECT artefact (second arm). Each SPECT was explored using two image process based on a Butterworth prefilter and post-filter: the original image processing (reconstruction A) with a cut-off frequency equals to 37% of the Nyquist frequency and order equals to 7, and a second image processing (reconstruction B) with a cut-off frequency equals to 25% of the Nyquist frequency and order equals to 5. For each patient, sum stress or rest score with and without septum (SSRS and SSRSws) were calculated with the two reconstructions. No significant statistical difference between SSRSa and SSRSb was identified for the first arm (P = 0.54) and the relative difference ∆r was - 0.5 ± 11.1% (95% CI - 2.7 to 1.7). We found a significant statistical difference between SSRSa and SSRSb for the second arm (p < 0.0001) and the relative difference ∆r was 69.7 ± 16.2% (95% CI 66.6-72.9).
Conclusion: In conclusion, using a Butterworth prefilter and post-filter cut-off frequency equal to 25% of the Nyquist frequency before iterative reconstruction generates less artefact and improves myocardial SPECT specificity without affecting sensibility compared with the original reconstruction.
EJNMMI ResearchRADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING&nb-
CiteScore
5.90
自引率
3.10%
发文量
72
审稿时长
13 weeks
期刊介绍:
EJNMMI Research publishes new basic, translational and clinical research in the field of nuclear medicine and molecular imaging. Regular features include original research articles, rapid communication of preliminary data on innovative research, interesting case reports, editorials, and letters to the editor. Educational articles on basic sciences, fundamental aspects and controversy related to pre-clinical and clinical research or ethical aspects of research are also welcome. Timely reviews provide updates on current applications, issues in imaging research and translational aspects of nuclear medicine and molecular imaging technologies.
The main emphasis is placed on the development of targeted imaging with radiopharmaceuticals within the broader context of molecular probes to enhance understanding and characterisation of the complex biological processes underlying disease and to develop, test and guide new treatment modalities, including radionuclide therapy.