{"title":"Troubleshooting Cochlear Implant Malfunction Using Neural Response Telemetry and Normal Saline.","authors":"Milind Sagar, Prem Sagar, Rajeev Kumar, Pallavi Rani","doi":"10.5152/iao.2024.231116","DOIUrl":null,"url":null,"abstract":"<p><p>Cochlear implantation has become a standard of care for a child diagnosed with bilateral profound sensorineural hearing loss with a structured surgical standard operating procedure. A 3-year-old boy with bilateral profound prelingual sensorineural deafness underwent a Med-EL Sonata Ti100 implant. We faced a peculiar situation intraoperatively after inserting the electrodes and closing the wound. The impedance recording indicated high ground path impedance with short-circuiting of few electrodes. As a bionic implant, its electronic components may at times malfunction both intraoperatively and/or postoperatively; therefore, neural response telemetry (NRT) was invented to check it. By using NRT and a few milliliters of normal saline, we were able to diagnose as well as rectify the malfunctioning of the implant.</p>","PeriodicalId":94238,"journal":{"name":"The journal of international advanced otology","volume":"20 1","pages":"89-93"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10895891/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The journal of international advanced otology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5152/iao.2024.231116","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Cochlear implantation has become a standard of care for a child diagnosed with bilateral profound sensorineural hearing loss with a structured surgical standard operating procedure. A 3-year-old boy with bilateral profound prelingual sensorineural deafness underwent a Med-EL Sonata Ti100 implant. We faced a peculiar situation intraoperatively after inserting the electrodes and closing the wound. The impedance recording indicated high ground path impedance with short-circuiting of few electrodes. As a bionic implant, its electronic components may at times malfunction both intraoperatively and/or postoperatively; therefore, neural response telemetry (NRT) was invented to check it. By using NRT and a few milliliters of normal saline, we were able to diagnose as well as rectify the malfunctioning of the implant.