A hybrid solar-driven vacuum thermionic generator and looped multi-stage thermoacoustically driven cryocooler system: Exergy- and emergy-based analysis and optimization
{"title":"A hybrid solar-driven vacuum thermionic generator and looped multi-stage thermoacoustically driven cryocooler system: Exergy- and emergy-based analysis and optimization","authors":"Yasaman Yousefi, A. Noorpoor, F. Boyaghchi","doi":"10.1063/5.0192008","DOIUrl":null,"url":null,"abstract":"Significant high-quality heat is wasted in the vacuum thermionic generator (VTIG), which can be efficiently utilized as a prime mover of a bottoming system for cogeneration applications. For this purpose, a new environmental-friendly hybrid system composed of a heliostat solar field, VTIG, and looped multi-stage thermoacoustically driven cryocooler (LMTC) is established, in which the high-temperature heat source of the solar receiver runs the VTIG to generate power, and the LMTC recovers the waste heat of the VTIG to produce a cooling load. Thermodynamic, economic, and environmental analyses of the system are carried out based on exergy and emergy concepts. Moreover, a parametric study is performed to assess the effect of design parameters on the system's thermodynamic, economic, and environmental criteria. Finally, the multi-criteria salp swarm optimization algorithm and decision-making procedures are conducted to improve the exergetic performance and decrease the system's cost and monetary emergy rates along with the environmental impact and ecological emergy rate. Findings depict that at the reliable, optimal operation of the system, the exergetic efficiency can reach 29.36% with a maximum power of 17.2 MW and cooling load of 0.260 MW. The system's cost and monetary emergy rate can be reduced to 0.059 $/s and 5.94 × 1010 seJ/s, with 10.6% and 10% reductions, respectively. Moreover, the environmental impact and ecological emergy rates decline by 6% and 7.4%, respectively. The theoretical findings may offer guidance for the optimum designing and practical running of such a solar solid-state cogeneration system.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":"38 20","pages":""},"PeriodicalIF":17.7000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0192008","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Significant high-quality heat is wasted in the vacuum thermionic generator (VTIG), which can be efficiently utilized as a prime mover of a bottoming system for cogeneration applications. For this purpose, a new environmental-friendly hybrid system composed of a heliostat solar field, VTIG, and looped multi-stage thermoacoustically driven cryocooler (LMTC) is established, in which the high-temperature heat source of the solar receiver runs the VTIG to generate power, and the LMTC recovers the waste heat of the VTIG to produce a cooling load. Thermodynamic, economic, and environmental analyses of the system are carried out based on exergy and emergy concepts. Moreover, a parametric study is performed to assess the effect of design parameters on the system's thermodynamic, economic, and environmental criteria. Finally, the multi-criteria salp swarm optimization algorithm and decision-making procedures are conducted to improve the exergetic performance and decrease the system's cost and monetary emergy rates along with the environmental impact and ecological emergy rate. Findings depict that at the reliable, optimal operation of the system, the exergetic efficiency can reach 29.36% with a maximum power of 17.2 MW and cooling load of 0.260 MW. The system's cost and monetary emergy rate can be reduced to 0.059 $/s and 5.94 × 1010 seJ/s, with 10.6% and 10% reductions, respectively. Moreover, the environmental impact and ecological emergy rates decline by 6% and 7.4%, respectively. The theoretical findings may offer guidance for the optimum designing and practical running of such a solar solid-state cogeneration system.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.