Percutaneous reduction of thoracolumbar fractures using monoaxial screws: Comparison of two instruments based on initial reduction and loss of reduction

IF 1.9 Q3 CLINICAL NEUROLOGY Brain & spine Pub Date : 2024-01-01 DOI:10.1016/j.bas.2024.102778
Esra Aydin , Philipp Schenk , Arija Jacobi , Thomas Mendel , Friederike Klauke , Bernhard Wilhelm Ullrich
{"title":"Percutaneous reduction of thoracolumbar fractures using monoaxial screws: Comparison of two instruments based on initial reduction and loss of reduction","authors":"Esra Aydin ,&nbsp;Philipp Schenk ,&nbsp;Arija Jacobi ,&nbsp;Thomas Mendel ,&nbsp;Friederike Klauke ,&nbsp;Bernhard Wilhelm Ullrich","doi":"10.1016/j.bas.2024.102778","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Percutaneous techniques for the surgical treatment of vertebral fractures are constantly progressing. There are different biomechanics involved.</p></div><div><h3>Research question</h3><p>Two percutaneous, monoaxial fixation systems with different reduction tools were analyzed in relation to their reduction capacity. Additionally, the impact of anterior fusion, fracture severity and bone quality on reduction and loss of reduction were examined.</p></div><div><h3>Material and methods</h3><p>117 cases were retrospectively included in the monocentric study. The subsample (N = 53) with complete data at follow-up times was used to analyze the influence of anterior fusion. The dependencies on fracture severity and bone quality were determined using Spearman and Pearson correlation.</p></div><div><h3>Results</h3><p>Both systems achieved equally good reduction (9° mean, 95%-CI: 8°–11°, p &lt; 0.001). Anterior fused patients showed not significant (p = 0.057) less loss of reduction over time. Fracture severity had neither an influence on reduction or loss of reduction. Bone quality was positively correlated with greater amount of reduction and less loss of reduction. Early reduction within two days correlated with a greater amount of reduction (p = 0.006). Screw diameters and the patient's weight had no influence on loss of reduction. Complications occurred only in “V2” group.</p></div><div><h3>Discussion and conclusion</h3><p>Both systems are equivalent in reduction ability. The additional anterior fusion did not result in significantly lower reduction losses. The subsample being small, is a limitation. Good bone quality correlates with better initial reduction and less reduction loss. A preoperative bone density measurement can lead to optimization of surgical techniques.</p></div>","PeriodicalId":72443,"journal":{"name":"Brain & spine","volume":"4 ","pages":"Article 102778"},"PeriodicalIF":1.9000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2772529424000341/pdfft?md5=4d24c8062211f379691ec64972c6d4ec&pid=1-s2.0-S2772529424000341-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brain & spine","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772529424000341","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction

Percutaneous techniques for the surgical treatment of vertebral fractures are constantly progressing. There are different biomechanics involved.

Research question

Two percutaneous, monoaxial fixation systems with different reduction tools were analyzed in relation to their reduction capacity. Additionally, the impact of anterior fusion, fracture severity and bone quality on reduction and loss of reduction were examined.

Material and methods

117 cases were retrospectively included in the monocentric study. The subsample (N = 53) with complete data at follow-up times was used to analyze the influence of anterior fusion. The dependencies on fracture severity and bone quality were determined using Spearman and Pearson correlation.

Results

Both systems achieved equally good reduction (9° mean, 95%-CI: 8°–11°, p < 0.001). Anterior fused patients showed not significant (p = 0.057) less loss of reduction over time. Fracture severity had neither an influence on reduction or loss of reduction. Bone quality was positively correlated with greater amount of reduction and less loss of reduction. Early reduction within two days correlated with a greater amount of reduction (p = 0.006). Screw diameters and the patient's weight had no influence on loss of reduction. Complications occurred only in “V2” group.

Discussion and conclusion

Both systems are equivalent in reduction ability. The additional anterior fusion did not result in significantly lower reduction losses. The subsample being small, is a limitation. Good bone quality correlates with better initial reduction and less reduction loss. A preoperative bone density measurement can lead to optimization of surgical techniques.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用单轴螺钉经皮固定胸腰椎骨折:基于初始复位和复位损失对两种器械进行比较
导言经皮手术治疗脊椎骨折的技术在不断进步。研究问题分析了两种经皮单轴固定系统和不同的复位工具的复位能力。此外,还研究了前路融合、骨折严重程度和骨质对复位和复位丧失的影响。随访时数据完整的子样本(N = 53)用于分析前路融合的影响。采用 Spearman 和 Pearson 相关性确定了骨折严重程度和骨质的相关性。结果两种方法都取得了同样好的复位效果(平均 9°,95%-CI:8°-11°,p < 0.001)。前路融合的患者随着时间的推移缩小的程度并不明显(p = 0.057)。骨折严重程度既不影响缩复,也不影响缩复损失。骨质与缩复量和缩复损失的减少呈正相关。两天内尽早复位与复位量的增加有关(p = 0.006)。螺钉直径和患者体重对缩小量没有影响。并发症仅发生在 "V2 "组。额外的前路融合并没有明显降低缩复损失。亚样本较小是一个限制因素。良好的骨质与较好的初始还原和较少的还原损失相关。术前骨密度测量可优化手术技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Brain & spine
Brain & spine Surgery
CiteScore
1.10
自引率
0.00%
发文量
0
审稿时长
71 days
期刊最新文献
Letter to the editor "Surgical management of Aneurysmal Subarachnoid Haemorrhage in a resource-constrained region: A Nigerian regional experience". Rare primary dedifferentiated liposarcoma of the thoracic spine: A case report and literature review. Fat beyond muscle: Assessing epimuscular fat of the lumbar spine and its association with vertebral level, demographics, BMI, and low back pain. The application of medical ethics in the developing countries - A neurosurgical perspective. EANS Epilepsy surgery Brain Dissection Course Vienna 2024.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1