Fausto Biancari, Tatu Juvonen, Sung-Min Cho, Francisco J Hernández Pérez, Camilla L'Acqua, Amr A Arafat, Mohammed M AlBarak, Mohamed Laimoud, Ilija Djordjevic, Robertas Samalavicius, Marta Alonso-Fernandez-Gatta, Sebastian D Sahli, Alexander Kaserer, Carmelo Dominici, Timo Mäkikallio
{"title":"External validation of the PC-ECMO score in postcardiotomy veno-arterial extracorporeal membrane oxygenation.","authors":"Fausto Biancari, Tatu Juvonen, Sung-Min Cho, Francisco J Hernández Pérez, Camilla L'Acqua, Amr A Arafat, Mohammed M AlBarak, Mohamed Laimoud, Ilija Djordjevic, Robertas Samalavicius, Marta Alonso-Fernandez-Gatta, Sebastian D Sahli, Alexander Kaserer, Carmelo Dominici, Timo Mäkikallio","doi":"10.1177/03913988241237701","DOIUrl":null,"url":null,"abstract":"<p><p>Reliable stratification of the risk of early mortality after postcardiotomy veno-arterial extracorporeal membrane oxygenation (V-A-ECMO) remains elusive. In this study, we externally validated the PC-ECMO score, a specific risk scoring method for prediction of in-hospital mortality after postcardiotomy V-A-ECMO. Overall, 614 patients who required V-A-ECMO after adult cardiac surgery were gathered from an individual patient data meta-analysis of nine studies on this topic. The AUC of the logistic PC-ECMO score in predicting in-hospital mortality was 0.678 (95%CI 0.630-0.726; <i>p</i> < 0.0001). The AUC of the logistic PC-ECMO score in predicting on V-A-ECMO mortality was 0.652 (95%CI 0.609-0.695; <i>p</i> < 0.0001). The Brier score of the logistic PC-ECMO score for in-hospital mortality was 0.193, the slope 0.909, the calibration-in-the-large 0.074 and the expected/observed mortality ratio 0.979. 95%CIs of the calibration belt of fit relationship between observed and predicted in-hospital mortality were never above or below the bisector (<i>p</i> = 0.072). The present findings suggest that the PC-ECMO score may be a valuable tool in clinical research for stratification of the risk of patients requiring postcardiotomy V-A-ECMO.</p>","PeriodicalId":13932,"journal":{"name":"International Journal of Artificial Organs","volume":" ","pages":"313-317"},"PeriodicalIF":1.4000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/03913988241237701","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/10 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Reliable stratification of the risk of early mortality after postcardiotomy veno-arterial extracorporeal membrane oxygenation (V-A-ECMO) remains elusive. In this study, we externally validated the PC-ECMO score, a specific risk scoring method for prediction of in-hospital mortality after postcardiotomy V-A-ECMO. Overall, 614 patients who required V-A-ECMO after adult cardiac surgery were gathered from an individual patient data meta-analysis of nine studies on this topic. The AUC of the logistic PC-ECMO score in predicting in-hospital mortality was 0.678 (95%CI 0.630-0.726; p < 0.0001). The AUC of the logistic PC-ECMO score in predicting on V-A-ECMO mortality was 0.652 (95%CI 0.609-0.695; p < 0.0001). The Brier score of the logistic PC-ECMO score for in-hospital mortality was 0.193, the slope 0.909, the calibration-in-the-large 0.074 and the expected/observed mortality ratio 0.979. 95%CIs of the calibration belt of fit relationship between observed and predicted in-hospital mortality were never above or below the bisector (p = 0.072). The present findings suggest that the PC-ECMO score may be a valuable tool in clinical research for stratification of the risk of patients requiring postcardiotomy V-A-ECMO.
期刊介绍:
The International Journal of Artificial Organs (IJAO) publishes peer-reviewed research and clinical, experimental and theoretical, contributions to the field of artificial, bioartificial and tissue-engineered organs. The mission of the IJAO is to foster the development and optimization of artificial, bioartificial and tissue-engineered organs, for implantation or use in procedures, to treat functional deficits of all human tissues and organs.