Finite Element Analysis of the Effect of Femoral Prosthesis Varus and Valgus Angle Installation on the Lateral Compartment in Unicompartmental Knee Arthroplasty.
Yonggui Wang, Chongyang Xu, Bo Yang, Fei Yu, Ai Guo
{"title":"Finite Element Analysis of the Effect of Femoral Prosthesis Varus and Valgus Angle Installation on the Lateral Compartment in Unicompartmental Knee Arthroplasty.","authors":"Yonggui Wang, Chongyang Xu, Bo Yang, Fei Yu, Ai Guo","doi":"10.1272/jnms.JNMS.2024_91-110","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This study used finite element analysis (FEA) to investigate the effect of varus and valgus angle on the lateral compartment in unicompartmental knee arthroplasty (UKA).</p><p><strong>Methods: </strong>One patient who underwent UKA was enrolled as the subject. Thirteen working conditions of the femoral prosthesis were simulated at varus and valgus angles of 0°, 2°, 4°, 6°, 8°, 10°, and 12°. A load of 1,000 N was applied downward along the mechanical axis of the femur, and the highest stress values on the surface of the polyethylene liner, cancellous bone under the tibial prosthesis, cartilage of femur lateral condyle, lateral meniscus, and tibial lateral plateau cartilage in each model were recorded. The six highest points were used to calculate the mean value.</p><p><strong>Results: </strong>The highest stress values on the surface of the polyethylene liner, cancellous bone under the tibial prosthesis, cartilage of femur lateral condyle, lateral meniscus, and tibial lateral plateau cartilage increased with an increase in the femoral prosthesis varus/valgus angle. As compared with the standard position of the femoral prosthesis, there was no significant difference in the surface stress values of the polyethylene liner, cancellous bone under the tibial prosthesis, cartilage of femur lateral condyle, lateral meniscus and tibial lateral plateau cartilage when the femoral prosthesis varus/valgus angle was less than 4° (p > 0.05). In addition, the stress magnitude on the polyethylene liner, cancellous bone under the tibial prosthesis, cartilage of femur lateral condyle, lateral meniscus, and tibial lateral plateau cartilage significantly increased when the femoral prosthesis varus/valgus angle was greater than 4° (p < 0.001).</p><p><strong>Conclusions: </strong>The optimal femoral prosthesis varus/valgus angle in UKA was less than 4°.</p>","PeriodicalId":56076,"journal":{"name":"Journal of Nippon Medical School","volume":"91 1","pages":"88-98"},"PeriodicalIF":1.2000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Nippon Medical School","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1272/jnms.JNMS.2024_91-110","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0
Abstract
Background: This study used finite element analysis (FEA) to investigate the effect of varus and valgus angle on the lateral compartment in unicompartmental knee arthroplasty (UKA).
Methods: One patient who underwent UKA was enrolled as the subject. Thirteen working conditions of the femoral prosthesis were simulated at varus and valgus angles of 0°, 2°, 4°, 6°, 8°, 10°, and 12°. A load of 1,000 N was applied downward along the mechanical axis of the femur, and the highest stress values on the surface of the polyethylene liner, cancellous bone under the tibial prosthesis, cartilage of femur lateral condyle, lateral meniscus, and tibial lateral plateau cartilage in each model were recorded. The six highest points were used to calculate the mean value.
Results: The highest stress values on the surface of the polyethylene liner, cancellous bone under the tibial prosthesis, cartilage of femur lateral condyle, lateral meniscus, and tibial lateral plateau cartilage increased with an increase in the femoral prosthesis varus/valgus angle. As compared with the standard position of the femoral prosthesis, there was no significant difference in the surface stress values of the polyethylene liner, cancellous bone under the tibial prosthesis, cartilage of femur lateral condyle, lateral meniscus and tibial lateral plateau cartilage when the femoral prosthesis varus/valgus angle was less than 4° (p > 0.05). In addition, the stress magnitude on the polyethylene liner, cancellous bone under the tibial prosthesis, cartilage of femur lateral condyle, lateral meniscus, and tibial lateral plateau cartilage significantly increased when the femoral prosthesis varus/valgus angle was greater than 4° (p < 0.001).
Conclusions: The optimal femoral prosthesis varus/valgus angle in UKA was less than 4°.
期刊介绍:
The international effort to understand, treat and control disease involve clinicians and researchers from many medical and biological science disciplines. The Journal of Nippon Medical School (JNMS) is the official journal of the Medical Association of Nippon Medical School and is dedicated to furthering international exchange of medical science experience and opinion. It provides an international forum for researchers in the fields of bascic and clinical medicine to introduce, discuss and exchange thier novel achievements in biomedical science and a platform for the worldwide dissemination and steering of biomedical knowledge for the benefit of human health and welfare. Properly reasoned discussions disciplined by appropriate references to existing bodies of knowledge or aimed at motivating the creation of such knowledge is the aim of the journal.